Calculation of characteristics of X-ray devices

Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less expose...

Full description

Bibliographic Details
Main Author: Orobinskyi A. N.
Format: Article
Language:English
Published: Politehperiodika 2015-12-01
Series:Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
Subjects:
Online Access:http://www.tkea.com.ua/tkea/2015/5-6_2015/pdf/10.pdf
id doaj-a78b73c488d74434a445fac540559a35
record_format Article
spelling doaj-a78b73c488d74434a445fac540559a352020-11-25T01:26:10ZengPolitehperiodikaTekhnologiya i Konstruirovanie v Elektronnoi Apparature2225-58182309-99922015-12-015-6556310.15222/TKEA2015.5-6.55Calculation of characteristics of X-ray devicesOrobinskyi A. N. 0Ukraine, Kharkov, National Scientific Centre "Institute of Metrology"Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less exposed to radiation. When developing an X-ray device, it is necessary to choose an X-ray tube and filters taking into account the application domain of the device. In order to do this, one should know anode voltage, X-ray tube anode current, material and thickness of filters, i.e. to calculate these characteristics at the set quality of X-ray radiation. The known published studies do not give any solution to this problem. The scientific novelty of this work is that it establishes the interdependence between main characteristics of the X-ray device: the function of the device defines the quality of X-ray radiation (mean photon energy and air kerma power); mean photon energy depends on the X-ray anode tube voltage and spectral resolution; air kerma power depends on anode tube voltage, current of X-ray tube anode, spectral resolution, thicknesses of the filters and their materials; spectral resolution depends on thicknesses of filters and their materials; thickness of filters depends on the material of the filter (the linear coefficient of weakening of X-ray radiation). Knowledge of interdependence of basic characteristics of the X-ray devices allowes developing simple algorithm for their calculation at the values of homogeneity coefficient from 0,8 to 1, which makes it possible to choose an X-ray tube and filters with the purpose of obtaining X-ray radiation of the set quality. http://www.tkea.com.ua/tkea/2015/5-6_2015/pdf/10.pdfX-ray deviceX-ray tubeX-ray radiationanode voltageanode currentspectral resolutionmean photon energyair kerma power
collection DOAJ
language English
format Article
sources DOAJ
author Orobinskyi A. N.
spellingShingle Orobinskyi A. N.
Calculation of characteristics of X-ray devices
Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
X-ray device
X-ray tube
X-ray radiation
anode voltage
anode current
spectral resolution
mean photon energy
air kerma power
author_facet Orobinskyi A. N.
author_sort Orobinskyi A. N.
title Calculation of characteristics of X-ray devices
title_short Calculation of characteristics of X-ray devices
title_full Calculation of characteristics of X-ray devices
title_fullStr Calculation of characteristics of X-ray devices
title_full_unstemmed Calculation of characteristics of X-ray devices
title_sort calculation of characteristics of x-ray devices
publisher Politehperiodika
series Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
issn 2225-5818
2309-9992
publishDate 2015-12-01
description Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less exposed to radiation. When developing an X-ray device, it is necessary to choose an X-ray tube and filters taking into account the application domain of the device. In order to do this, one should know anode voltage, X-ray tube anode current, material and thickness of filters, i.e. to calculate these characteristics at the set quality of X-ray radiation. The known published studies do not give any solution to this problem. The scientific novelty of this work is that it establishes the interdependence between main characteristics of the X-ray device: the function of the device defines the quality of X-ray radiation (mean photon energy and air kerma power); mean photon energy depends on the X-ray anode tube voltage and spectral resolution; air kerma power depends on anode tube voltage, current of X-ray tube anode, spectral resolution, thicknesses of the filters and their materials; spectral resolution depends on thicknesses of filters and their materials; thickness of filters depends on the material of the filter (the linear coefficient of weakening of X-ray radiation). Knowledge of interdependence of basic characteristics of the X-ray devices allowes developing simple algorithm for their calculation at the values of homogeneity coefficient from 0,8 to 1, which makes it possible to choose an X-ray tube and filters with the purpose of obtaining X-ray radiation of the set quality.
topic X-ray device
X-ray tube
X-ray radiation
anode voltage
anode current
spectral resolution
mean photon energy
air kerma power
url http://www.tkea.com.ua/tkea/2015/5-6_2015/pdf/10.pdf
work_keys_str_mv AT orobinskyian calculationofcharacteristicsofxraydevices
_version_ 1725110409464119296