SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS

At present heart transplantation is the most effective method for treating patients with terminal stage of heart insufficiency. And now the number of possible recipients exceeds the number of performing transplantations several times in the world [1]. Due to the limited number of donors there is a n...

Full description

Bibliographic Details
Main Authors: K. O. Barbukhatti, V. S. Pykhteev, S. S. Babeshko, V. I. Kaleda, V. A. Porhanov
Format: Article
Language:Russian
Published: Kubankurortresurs, OOO 2019-02-01
Series:Инновационная медицина Кубани
Subjects:
Online Access:https://inovmed.elpub.ru/jour/article/view/56
id doaj-a7380cc7a29c432a8f5f742e7b0ab423
record_format Article
spelling doaj-a7380cc7a29c432a8f5f742e7b0ab4232021-10-08T12:46:23ZrusKubankurortresurs, OOOИнновационная медицина Кубани2500-02682541-98972019-02-0151424856SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERSK. O. Barbukhatti0V. S. Pykhteev1S. S. Babeshko2V. I. Kaleda3V. A. Porhanov4Scientific Research Institute – Ochapovsky Regional Clinical Hospital no. 1, The Krasnodar Krai Ministry of HealthKuban State Medical University, Ministry of Health of the Russian FederationScientific Research Institute – Ochapovsky Regional Clinical Hospital no. 1, The Krasnodar Krai Ministry of HealthScientific Research Institute – Ochapovsky Regional Clinical Hospital no. 1, The Krasnodar Krai Ministry of HealthScientific Research Institute – Ochapovsky Regional Clinical Hospital no. 1, The Krasnodar Krai Ministry of HealthAt present heart transplantation is the most effective method for treating patients with terminal stage of heart insufficiency. And now the number of possible recipients exceeds the number of performing transplantations several times in the world [1]. Due to the limited number of donors there is a necessity to rational employment for donor organs [2]. Deficit of donor hearts urged on surgeons to extend selection criteria and demands for heart harvesting in so called suboptimal donors which leads to increased number and timeliness performance of transplantations [3, 4, 5]. In the present article we demonstrated two clinical cases with successful orthotopic heart transplantation (OHT) with donor organs usage, which differed rather significantly regarding aortic dimensions, and this fact necessitated performance of reduction aortoplasty in recipients. Besides, we presented a case with aт OHT patient with ascending aorta aneurism, complicated dissection type II DeBakey, who was indicated supracoronary grafting of the ascending aorta and a part of aortic arch before the transplantation.https://inovmed.elpub.ru/jour/article/view/56heart transplantationascending aorta aneurysmaortoplasty
collection DOAJ
language Russian
format Article
sources DOAJ
author K. O. Barbukhatti
V. S. Pykhteev
S. S. Babeshko
V. I. Kaleda
V. A. Porhanov
spellingShingle K. O. Barbukhatti
V. S. Pykhteev
S. S. Babeshko
V. I. Kaleda
V. A. Porhanov
SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
Инновационная медицина Кубани
heart transplantation
ascending aorta aneurysm
aortoplasty
author_facet K. O. Barbukhatti
V. S. Pykhteev
S. S. Babeshko
V. I. Kaleda
V. A. Porhanov
author_sort K. O. Barbukhatti
title SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
title_short SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
title_full SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
title_fullStr SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
title_full_unstemmed SOME FEATURES OF ORTHOTOPIC HEART TRANSPLANTATION WITH DISCREPANCIES BETWEEN DONOR AND RECIPIENT AORTIC DIAMETERS
title_sort some features of orthotopic heart transplantation with discrepancies between donor and recipient aortic diameters
publisher Kubankurortresurs, OOO
series Инновационная медицина Кубани
issn 2500-0268
2541-9897
publishDate 2019-02-01
description At present heart transplantation is the most effective method for treating patients with terminal stage of heart insufficiency. And now the number of possible recipients exceeds the number of performing transplantations several times in the world [1]. Due to the limited number of donors there is a necessity to rational employment for donor organs [2]. Deficit of donor hearts urged on surgeons to extend selection criteria and demands for heart harvesting in so called suboptimal donors which leads to increased number and timeliness performance of transplantations [3, 4, 5]. In the present article we demonstrated two clinical cases with successful orthotopic heart transplantation (OHT) with donor organs usage, which differed rather significantly regarding aortic dimensions, and this fact necessitated performance of reduction aortoplasty in recipients. Besides, we presented a case with aт OHT patient with ascending aorta aneurism, complicated dissection type II DeBakey, who was indicated supracoronary grafting of the ascending aorta and a part of aortic arch before the transplantation.
topic heart transplantation
ascending aorta aneurysm
aortoplasty
url https://inovmed.elpub.ru/jour/article/view/56
work_keys_str_mv AT kobarbukhatti somefeaturesoforthotopichearttransplantationwithdiscrepanciesbetweendonorandrecipientaorticdiameters
AT vspykhteev somefeaturesoforthotopichearttransplantationwithdiscrepanciesbetweendonorandrecipientaorticdiameters
AT ssbabeshko somefeaturesoforthotopichearttransplantationwithdiscrepanciesbetweendonorandrecipientaorticdiameters
AT vikaleda somefeaturesoforthotopichearttransplantationwithdiscrepanciesbetweendonorandrecipientaorticdiameters
AT vaporhanov somefeaturesoforthotopichearttransplantationwithdiscrepanciesbetweendonorandrecipientaorticdiameters
_version_ 1716838445475692544