Developed Design for Humeral Head Replacement Using 3D Surface Mapping

Izmēru un ģeometrisko datu novērtējums, kas attiecas uz pleca kaula galviņas nomaiņas (PKGN) objektiem, nepieciešams, lai risinātu virkni reversīvās inženierijas (RI) problēmu. Šajā darbā cilvēka pleca kaula galviņas divdimensiju novērtējums tika veikts ar datortomogrāfijas palīdzību (RI) ietvaros,...

Full description

Bibliographic Details
Main Author: Salah H. R.
Format: Article
Language:English
Published: Sciendo 2014-12-01
Series:Latvian Journal of Physics and Technical Sciences
Subjects:
Online Access:https://doi.org/10.1515/lpts-2014-0035
id doaj-a6f0d5c6c7444b97b5db594d3064a026
record_format Article
spelling doaj-a6f0d5c6c7444b97b5db594d3064a0262021-09-06T19:20:05ZengSciendoLatvian Journal of Physics and Technical Sciences0868-82572014-12-01516415510.1515/lpts-2014-0035lpts-2014-0035Developed Design for Humeral Head Replacement Using 3D Surface MappingSalah H. R.0Ali National Institute for Standards, Eng. and Surface Metrology, Precision Engineering Division, Giza 12211-136, EGYPTIzmēru un ģeometrisko datu novērtējums, kas attiecas uz pleca kaula galviņas nomaiņas (PKGN) objektiem, nepieciešams, lai risinātu virkni reversīvās inženierijas (RI) problēmu. Šajā darbā cilvēka pleca kaula galviņas divdimensiju novērtējums tika veikts ar datortomogrāfijas palīdzību (RI) ietvaros, un pēc tam objekta divdimensiju attēlojums tika pārveidots trīsdimensiju. Pārveidojums bija sekmīgs, parādot pleca kaula galviņas izmēru un ģeometrijas atšķirības starp 2D un 3D novērtējumiem. Autori izanalizēja un eksperimentāli apstiprināja statistisko informāciju pēc dotā veida anatomiskiem objektiem. Saspiešanas sasprindzinājumi, kuri ietekmē trīsdimensiju virsmas attēlojuma ģeometriju, tika analizēti ar gala-elementu simulācijas metodi, lietojot programmu SolidWorks. Biomehaniskajam PKGN dizainam tika atlasīti piemēroti materiāli. Apspriesta dažādu biomateriālu ar metālisko pamatu reakcija uz mainīgām slodzēm. Tiek piedāvāta pleca kaula galviņas - kā anatomiskas, tā mākslīgas - trīs dimensijas mērīšanas metodoloģijas. Dota datortomogrāfisko precīzo mērījumu rezultātu detalizēta interpretācija.https://doi.org/10.1515/lpts-2014-0035humeral headdimensional assessmentimage metrologyhhr design3d surface mapping
collection DOAJ
language English
format Article
sources DOAJ
author Salah H. R.
spellingShingle Salah H. R.
Developed Design for Humeral Head Replacement Using 3D Surface Mapping
Latvian Journal of Physics and Technical Sciences
humeral head
dimensional assessment
image metrology
hhr design
3d surface mapping
author_facet Salah H. R.
author_sort Salah H. R.
title Developed Design for Humeral Head Replacement Using 3D Surface Mapping
title_short Developed Design for Humeral Head Replacement Using 3D Surface Mapping
title_full Developed Design for Humeral Head Replacement Using 3D Surface Mapping
title_fullStr Developed Design for Humeral Head Replacement Using 3D Surface Mapping
title_full_unstemmed Developed Design for Humeral Head Replacement Using 3D Surface Mapping
title_sort developed design for humeral head replacement using 3d surface mapping
publisher Sciendo
series Latvian Journal of Physics and Technical Sciences
issn 0868-8257
publishDate 2014-12-01
description Izmēru un ģeometrisko datu novērtējums, kas attiecas uz pleca kaula galviņas nomaiņas (PKGN) objektiem, nepieciešams, lai risinātu virkni reversīvās inženierijas (RI) problēmu. Šajā darbā cilvēka pleca kaula galviņas divdimensiju novērtējums tika veikts ar datortomogrāfijas palīdzību (RI) ietvaros, un pēc tam objekta divdimensiju attēlojums tika pārveidots trīsdimensiju. Pārveidojums bija sekmīgs, parādot pleca kaula galviņas izmēru un ģeometrijas atšķirības starp 2D un 3D novērtējumiem. Autori izanalizēja un eksperimentāli apstiprināja statistisko informāciju pēc dotā veida anatomiskiem objektiem. Saspiešanas sasprindzinājumi, kuri ietekmē trīsdimensiju virsmas attēlojuma ģeometriju, tika analizēti ar gala-elementu simulācijas metodi, lietojot programmu SolidWorks. Biomehaniskajam PKGN dizainam tika atlasīti piemēroti materiāli. Apspriesta dažādu biomateriālu ar metālisko pamatu reakcija uz mainīgām slodzēm. Tiek piedāvāta pleca kaula galviņas - kā anatomiskas, tā mākslīgas - trīs dimensijas mērīšanas metodoloģijas. Dota datortomogrāfisko precīzo mērījumu rezultātu detalizēta interpretācija.
topic humeral head
dimensional assessment
image metrology
hhr design
3d surface mapping
url https://doi.org/10.1515/lpts-2014-0035
work_keys_str_mv AT salahhr developeddesignforhumeralheadreplacementusing3dsurfacemapping
_version_ 1717777312903069696