The Use and Misuse of Pressure Regulators
In spite of its operational simplicity, the self-actuated regulator can be misapplied. The author discusses droop, stability and range-ability—an understanding of these factors reduces the chance of a poor application. He also reviews noisy operation, sizing, economics and other aspects of the regul...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
1969-06-01
|
Series: | Measurement + Control |
Online Access: | https://doi.org/10.1177/002029406900200603 |
id |
doaj-a67bf14d249247b6a6f7201380944234 |
---|---|
record_format |
Article |
spelling |
doaj-a67bf14d249247b6a6f72013809442342020-11-25T03:01:43ZengSAGE PublishingMeasurement + Control0020-29401969-06-01210.1177/002029406900200603The Use and Misuse of Pressure RegulatorsR. L. Moore0 Instrument Engineer in the Design Division of the Du Pont Company, Wilmington, DelawareIn spite of its operational simplicity, the self-actuated regulator can be misapplied. The author discusses droop, stability and range-ability—an understanding of these factors reduces the chance of a poor application. He also reviews noisy operation, sizing, economics and other aspects of the regulator.https://doi.org/10.1177/002029406900200603 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
R. L. Moore |
spellingShingle |
R. L. Moore The Use and Misuse of Pressure Regulators Measurement + Control |
author_facet |
R. L. Moore |
author_sort |
R. L. Moore |
title |
The Use and Misuse of Pressure Regulators |
title_short |
The Use and Misuse of Pressure Regulators |
title_full |
The Use and Misuse of Pressure Regulators |
title_fullStr |
The Use and Misuse of Pressure Regulators |
title_full_unstemmed |
The Use and Misuse of Pressure Regulators |
title_sort |
use and misuse of pressure regulators |
publisher |
SAGE Publishing |
series |
Measurement + Control |
issn |
0020-2940 |
publishDate |
1969-06-01 |
description |
In spite of its operational simplicity, the self-actuated regulator can be misapplied. The author discusses droop, stability and range-ability—an understanding of these factors reduces the chance of a poor application. He also reviews noisy operation, sizing, economics and other aspects of the regulator. |
url |
https://doi.org/10.1177/002029406900200603 |
work_keys_str_mv |
AT rlmoore theuseandmisuseofpressureregulators AT rlmoore useandmisuseofpressureregulators |
_version_ |
1724692307181043712 |