Stabilization of Electrical Parameters of Machine-Converter Voltage Source

The paper is devoted to development of Machine-Converter Source (MCS), which forms the output voltage waveform of electric generator as sum of EMFs with near frequencies. As electric modulation generator is used a synchronous generator and asynchronous exciter that have both common driving shaft and...

Full description

Bibliographic Details
Main Authors: Yu. N. Dementyev, A. V. Glazachev, K. N. Negodin, I. Vajda, V. I. Susdorf
Format: Article
Language:English
Published: European Alliance for Innovation (EAI) 2018-01-01
Series:EAI Endorsed Transactions on Energy Web
Subjects:
Online Access:http://eudl.eu/doi/10.4108/eai.30-1-2018.153813
id doaj-a67a37ebdf274bc39326cd87a08e3baf
record_format Article
spelling doaj-a67a37ebdf274bc39326cd87a08e3baf2020-11-25T01:28:32ZengEuropean Alliance for Innovation (EAI)EAI Endorsed Transactions on Energy Web2032-944X2018-01-015161910.4108/eai.30-1-2018.153813Stabilization of Electrical Parameters of Machine-Converter Voltage SourceYu. N. Dementyev0A. V. Glazachev1K. N. Negodin2I. Vajda3V. I. Susdorf4Tomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian Federation; dementev@tpu.ruTomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian FederationTomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian FederationTomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian Federation; Obuda University, Kando Kalman Polytechnic, Becsi ut 96/B, 1034, Budapest, HungaryKomsomolsk-na-Amure State Technical University, Electric Drive and Automation of Industrial Installations, av. Lenina, 27, 681013, Komsomolsk-na-Amure, Russian FederationThe paper is devoted to development of Machine-Converter Source (MCS), which forms the output voltage waveform of electric generator as sum of EMFs with near frequencies. As electric modulation generator is used a synchronous generator and asynchronous exciter that have both common driving shaft and common housing. We studied the automatic control systems for output electrical parameters of MCS when changing speed of driving shaft and load power in wide ranges.http://eudl.eu/doi/10.4108/eai.30-1-2018.153813Machine-converter sourcessynchronous generatorarmature windingasynchronous exciterPWM autonomous invertercycloconvertervoltagefrequency
collection DOAJ
language English
format Article
sources DOAJ
author Yu. N. Dementyev
A. V. Glazachev
K. N. Negodin
I. Vajda
V. I. Susdorf
spellingShingle Yu. N. Dementyev
A. V. Glazachev
K. N. Negodin
I. Vajda
V. I. Susdorf
Stabilization of Electrical Parameters of Machine-Converter Voltage Source
EAI Endorsed Transactions on Energy Web
Machine-converter sources
synchronous generator
armature winding
asynchronous exciter
PWM autonomous inverter
cycloconverter
voltage
frequency
author_facet Yu. N. Dementyev
A. V. Glazachev
K. N. Negodin
I. Vajda
V. I. Susdorf
author_sort Yu. N. Dementyev
title Stabilization of Electrical Parameters of Machine-Converter Voltage Source
title_short Stabilization of Electrical Parameters of Machine-Converter Voltage Source
title_full Stabilization of Electrical Parameters of Machine-Converter Voltage Source
title_fullStr Stabilization of Electrical Parameters of Machine-Converter Voltage Source
title_full_unstemmed Stabilization of Electrical Parameters of Machine-Converter Voltage Source
title_sort stabilization of electrical parameters of machine-converter voltage source
publisher European Alliance for Innovation (EAI)
series EAI Endorsed Transactions on Energy Web
issn 2032-944X
publishDate 2018-01-01
description The paper is devoted to development of Machine-Converter Source (MCS), which forms the output voltage waveform of electric generator as sum of EMFs with near frequencies. As electric modulation generator is used a synchronous generator and asynchronous exciter that have both common driving shaft and common housing. We studied the automatic control systems for output electrical parameters of MCS when changing speed of driving shaft and load power in wide ranges.
topic Machine-converter sources
synchronous generator
armature winding
asynchronous exciter
PWM autonomous inverter
cycloconverter
voltage
frequency
url http://eudl.eu/doi/10.4108/eai.30-1-2018.153813
work_keys_str_mv AT yundementyev stabilizationofelectricalparametersofmachineconvertervoltagesource
AT avglazachev stabilizationofelectricalparametersofmachineconvertervoltagesource
AT knnegodin stabilizationofelectricalparametersofmachineconvertervoltagesource
AT ivajda stabilizationofelectricalparametersofmachineconvertervoltagesource
AT visusdorf stabilizationofelectricalparametersofmachineconvertervoltagesource
_version_ 1725101043670319104