Repair and retrofitting of buildings post earthquake

This paper discusses the damage types, repair methods and retrofitting of buildings post an earthquake. Data were taken by conducting surveys and assessment of buildings directly, both engineered and non-engineered buildings affected by the West Sumatra earthquake in 2009. Some causes of damage, amo...

Full description

Bibliographic Details
Main Author: Zaidir
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/16/e3sconf_iceedm2020_05023.pdf
id doaj-a66757e490bd4b19b1d14d051c4399a3
record_format Article
spelling doaj-a66757e490bd4b19b1d14d051c4399a32021-08-26T09:26:54ZengEDP SciencesE3S Web of Conferences2267-12422020-01-011560502310.1051/e3sconf/202015605023e3sconf_iceedm2020_05023Repair and retrofitting of buildings post earthquakeZaidir0Civil Engineering Department, Engineering Faculty, Andalas UniversityThis paper discusses the damage types, repair methods and retrofitting of buildings post an earthquake. Data were taken by conducting surveys and assessment of buildings directly, both engineered and non-engineered buildings affected by the West Sumatra earthquake in 2009. Some causes of damage, among them is the detailing of reinforcement that do not follow the existing standard, soft-story effect, foundation failure, low material quality and does not meet the requirements, design and implementation of the construction do not follow the rules and technical provisions of the building earthquake resistant. Improvement and buildings retrofitting can be done after the buildings damage types or its components/parts and the quality of the building materials used were known. The structural analysis was done in order to know the cause of the building elements damaged and if the results of analysis with the latest regulations earthquake load, the building structures is able to withstand the earthquake loads and a repair is not required, but if not, the retrofitting is required.https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/16/e3sconf_iceedm2020_05023.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Zaidir
spellingShingle Zaidir
Repair and retrofitting of buildings post earthquake
E3S Web of Conferences
author_facet Zaidir
author_sort Zaidir
title Repair and retrofitting of buildings post earthquake
title_short Repair and retrofitting of buildings post earthquake
title_full Repair and retrofitting of buildings post earthquake
title_fullStr Repair and retrofitting of buildings post earthquake
title_full_unstemmed Repair and retrofitting of buildings post earthquake
title_sort repair and retrofitting of buildings post earthquake
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2020-01-01
description This paper discusses the damage types, repair methods and retrofitting of buildings post an earthquake. Data were taken by conducting surveys and assessment of buildings directly, both engineered and non-engineered buildings affected by the West Sumatra earthquake in 2009. Some causes of damage, among them is the detailing of reinforcement that do not follow the existing standard, soft-story effect, foundation failure, low material quality and does not meet the requirements, design and implementation of the construction do not follow the rules and technical provisions of the building earthquake resistant. Improvement and buildings retrofitting can be done after the buildings damage types or its components/parts and the quality of the building materials used were known. The structural analysis was done in order to know the cause of the building elements damaged and if the results of analysis with the latest regulations earthquake load, the building structures is able to withstand the earthquake loads and a repair is not required, but if not, the retrofitting is required.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/16/e3sconf_iceedm2020_05023.pdf
work_keys_str_mv AT zaidir repairandretrofittingofbuildingspostearthquake
_version_ 1721195847857733632