Research of adjustable parameters in the automated climatic systems at the aim of energy saving
In modern conditions the special attention should be given to the automated climatic systems with a view of energy saving. In this work processes of non-stationary heat exchange in the room served by automated climatic systems are considered. Modern methods of calculation of a thermal mode of a room...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peter the Great St. Petersburg Polytechnic University
2013-03-01
|
Series: | Инженерно-строительный журнал |
Subjects: | |
Online Access: | http://engstroy.spb.ru/index_2013_02/samarin.pdf |
id |
doaj-a5b70b1731304e22a64e0475c76be186 |
---|---|
record_format |
Article |
spelling |
doaj-a5b70b1731304e22a64e0475c76be1862020-11-25T02:13:30ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-47262071-03052013-03-013721318Research of adjustable parameters in the automated climatic systems at the aim of energy savingO.D. SamarinI.I. TishchenkovaIn modern conditions the special attention should be given to the automated climatic systems with a view of energy saving. In this work processes of non-stationary heat exchange in the room served by automated climatic systems are considered. Modern methods of calculation of a thermal mode of a room are stated. The interrelation between separate parameters of thermal stability of a room and automatic control of microclimate providing systems is investigated. Expression for calculation of controller gain is received. The end result is defined on the basis of receiving the approximate technique, allowing estimating the influence of a controller operating mode on total energy consumption by microclimate providing systems. This technique has a quite simple appearance and at further development allows development of engineering recommendations about the selection of optimum option of a controller operating mode for the engineering equipment. The statement is illustrated with numerical calculations by means of the created computer program and graphic examples.http://engstroy.spb.ru/index_2013_02/samarin.pdfenergy savingthermal balance of a roomautomated climatic systemcontroller gaincontroller operating modeenergy consumption |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
O.D. Samarin I.I. Tishchenkova |
spellingShingle |
O.D. Samarin I.I. Tishchenkova Research of adjustable parameters in the automated climatic systems at the aim of energy saving Инженерно-строительный журнал energy saving thermal balance of a room automated climatic system controller gain controller operating mode energy consumption |
author_facet |
O.D. Samarin I.I. Tishchenkova |
author_sort |
O.D. Samarin |
title |
Research of adjustable parameters in the automated climatic systems at the aim of energy saving |
title_short |
Research of adjustable parameters in the automated climatic systems at the aim of energy saving |
title_full |
Research of adjustable parameters in the automated climatic systems at the aim of energy saving |
title_fullStr |
Research of adjustable parameters in the automated climatic systems at the aim of energy saving |
title_full_unstemmed |
Research of adjustable parameters in the automated climatic systems at the aim of energy saving |
title_sort |
research of adjustable parameters in the automated climatic systems at the aim of energy saving |
publisher |
Peter the Great St. Petersburg Polytechnic University |
series |
Инженерно-строительный журнал |
issn |
2071-4726 2071-0305 |
publishDate |
2013-03-01 |
description |
In modern conditions the special attention should be given to the automated climatic systems with a view of energy saving. In this work processes of non-stationary heat exchange in the room served by automated climatic systems are considered. Modern methods of calculation of a thermal mode of a room are stated. The interrelation between separate parameters of thermal stability of a room and automatic control of microclimate providing systems is investigated. Expression for calculation of controller gain is received. The end result is defined on the basis of receiving the approximate technique, allowing estimating the influence of a controller operating mode on total energy consumption by microclimate providing systems. This technique has a quite simple appearance and at further development allows development of engineering recommendations about the selection of optimum option of a controller operating mode for the engineering equipment. The statement is illustrated with numerical calculations by means of the created computer program and graphic examples. |
topic |
energy saving thermal balance of a room automated climatic system controller gain controller operating mode energy consumption |
url |
http://engstroy.spb.ru/index_2013_02/samarin.pdf |
work_keys_str_mv |
AT odsamarin researchofadjustableparametersintheautomatedclimaticsystemsattheaimofenergysaving AT iitishchenkova researchofadjustableparametersintheautomatedclimaticsystemsattheaimofenergysaving |
_version_ |
1724904791111368704 |