Mitigation of Airborne Contaminant Spread through Simple Interventions in an Occupied Single-Family Home

Historically, reducing aerosol-based transmission of respired viruses in indoor environments has been of importance for controlling influenza viruses and common-cold rhinoviruses. The present public health emergency associated with SARS-CoV-2 makes this topic critically important. Yet to be tested i...

Full description

Bibliographic Details
Main Authors: Tanvir R. Khan, Danny S. Parker, Charles Withers
Format: Article
Language:English
Published: MDPI AG 2021-05-01
Series:International Journal of Environmental Research and Public Health
Subjects:
Online Access:https://www.mdpi.com/1660-4601/18/11/5880
Description
Summary:Historically, reducing aerosol-based transmission of respired viruses in indoor environments has been of importance for controlling influenza viruses and common-cold rhinoviruses. The present public health emergency associated with SARS-CoV-2 makes this topic critically important. Yet to be tested is the potential effectiveness of simple interventions that create an isolation zone (IZ) for a suspected/confirmed sick or sensitive person requiring quarantine. The intent in existing homes is to find a practical means to mitigate exposure to airborne contaminants. In creating an IZ in an occupied single-family home in the study, four simple strategies were tested. The test configurations were: (1) IZ windows closed with IZ bathroom exhaust ventilation fan off, (2) IZ windows closed with IZ exhaust fan on, (3) IZ window open with IZ exhaust fan off, and (4) IZ window open with IZ exhaust fan on. Incense-generated fine particulate matter (PM<sub>2.5</sub>) was used as a marker for virus transmission. The measured transfer of PM<sub>2.5</sub> from the IZ into the main zone (MZ) of the house enabled us to determine the relative effectiveness of four containment strategies. Collectively, the data from pressure differential (across zones) and PM<sub>2.5</sub> measurements suggested that the best containment strategy was achieved through continuously operating the bathroom exhaust fan while keeping the windows closed in the IZ (configuration 2). Interventions using open windows were found to be less reliable, due to variability in wind speed and direction, resulting in an unpredictable and sometimes detrimental pressure differential in the IZ with reference to MZ. Our findings strongly suggest a simple IZ exhaust ventilation strategy has the potential for mitigating the risk from the airborne spread of contaminants, such as SARS-CoV-2.
ISSN:1661-7827
1660-4601