Comparison of sensory-neural hearing between firefighters and office workers
Background: Rescuer systems personnel such as firefighters have importance in health assessment. Because of stressful situation, chemicals, metals, gases and noises, they need many physical and paraclinic examination such as audiometry in periodic examinations. Comparison of sensory - neural hearing...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2013-01-01
|
Series: | International Journal of Preventive Medicine |
Subjects: | |
Online Access: | http://www.ijpvmjournal.net/article.asp?issn=2008-7802;year=2013;volume=4;issue=1;spage=115;epage=119;aulast=Assadi |
id |
doaj-a5491f48a8b64fd9acf15d48ecb2cbb8 |
---|---|
record_format |
Article |
spelling |
doaj-a5491f48a8b64fd9acf15d48ecb2cbb82020-11-24T23:07:42ZengWolters Kluwer Medknow PublicationsInternational Journal of Preventive Medicine2008-78022008-82132013-01-0141115119Comparison of sensory-neural hearing between firefighters and office workersSeyedeh Negar AssadiHabibollah EsmailyLeila MostaanBackground: Rescuer systems personnel such as firefighters have importance in health assessment. Because of stressful situation, chemicals, metals, gases and noises, they need many physical and paraclinic examination such as audiometry in periodic examinations. Comparison of sensory - neural hearing between firefighters and office workers. Methods: A cross-sectional study had been done on firefighters and office workers with use of the clinical - health issues. Data had been analyzed in SPSS 11.5 by T-test and Chi-2 with significance level of P<0.05. Results: Mean of hearing threshold in firefighters′ right ear in 4000, 6000, 8000 Hz was 16.05±8.66 dB and in office workers was 15.20±6.47 dB with t=0.786 and P=0.433 had no significant difference, this mean in firefighters′ left ear was 16.17±8.12 dB and in office workers was 15.52±6.67 dB with t=0.617 and P=0.538 had no significant difference too. Mean of hearing threshold in firefighters′ right ear in age 40 or less than it in 4000 Hz was 20.51±10.11 dB and in office workers was 17.50±5.28 dB with t=2.153 and P=0.033 had significant difference. Conclusion: Mean of hearing threshold in firefighters in all frequencies was normal, except 4000 frequency. It showed the early effect of occupational exposure on hearing.http://www.ijpvmjournal.net/article.asp?issn=2008-7802;year=2013;volume=4;issue=1;spage=115;epage=119;aulast=AssadiChemical pollutionfirefightersensory-neural hearingsiren |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Seyedeh Negar Assadi Habibollah Esmaily Leila Mostaan |
spellingShingle |
Seyedeh Negar Assadi Habibollah Esmaily Leila Mostaan Comparison of sensory-neural hearing between firefighters and office workers International Journal of Preventive Medicine Chemical pollution firefighter sensory-neural hearing siren |
author_facet |
Seyedeh Negar Assadi Habibollah Esmaily Leila Mostaan |
author_sort |
Seyedeh Negar Assadi |
title |
Comparison of sensory-neural hearing between firefighters and office workers |
title_short |
Comparison of sensory-neural hearing between firefighters and office workers |
title_full |
Comparison of sensory-neural hearing between firefighters and office workers |
title_fullStr |
Comparison of sensory-neural hearing between firefighters and office workers |
title_full_unstemmed |
Comparison of sensory-neural hearing between firefighters and office workers |
title_sort |
comparison of sensory-neural hearing between firefighters and office workers |
publisher |
Wolters Kluwer Medknow Publications |
series |
International Journal of Preventive Medicine |
issn |
2008-7802 2008-8213 |
publishDate |
2013-01-01 |
description |
Background: Rescuer systems personnel such as firefighters have importance in health assessment. Because of stressful situation, chemicals, metals, gases and noises, they need many physical and paraclinic examination such as audiometry in periodic examinations. Comparison of sensory - neural hearing between firefighters and office workers.
Methods: A cross-sectional study had been done on firefighters and office workers with use of the clinical - health issues. Data had been analyzed in SPSS 11.5 by T-test and Chi-2 with significance level of P<0.05.
Results: Mean of hearing threshold in firefighters′ right ear in 4000, 6000, 8000 Hz was 16.05±8.66 dB and in office workers was 15.20±6.47 dB with t=0.786 and P=0.433 had no significant difference, this mean in firefighters′ left ear was 16.17±8.12 dB and in office workers was 15.52±6.67 dB with t=0.617 and P=0.538 had no significant difference too. Mean of hearing threshold in firefighters′ right ear in age 40 or less than it in 4000 Hz was 20.51±10.11 dB and in office workers was 17.50±5.28 dB with t=2.153 and P=0.033 had significant difference.
Conclusion: Mean of hearing threshold in firefighters in all frequencies was normal, except 4000 frequency. It showed the early effect of occupational exposure on hearing. |