Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.

<h4>Objectives</h4>The gold standard to obtain pressure-volume relations (PVR) of the heart, the conductance technology (PVRCond), is rarely used in children. PVR can also be obtained by 3D-echocardiography volume data combined with simultaneously measured pressure data by a mini pressur...

Full description

Bibliographic Details
Main Authors: Katharina Linden, Christian Winkler, Johannes Breuer, Ulrike Herberg
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2021-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0246031
id doaj-a509565e261b44d68b95cedd127ef185
record_format Article
spelling doaj-a509565e261b44d68b95cedd127ef1852021-07-30T04:31:15ZengPublic Library of Science (PLoS)PLoS ONE1932-62032021-01-01162e024603110.1371/journal.pone.0246031Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.Katharina LindenChristian WinklerJohannes BreuerUlrike Herberg<h4>Objectives</h4>The gold standard to obtain pressure-volume relations (PVR) of the heart, the conductance technology (PVRCond), is rarely used in children. PVR can also be obtained by 3D-echocardiography volume data combined with simultaneously measured pressure data by a mini pressure-wire (PVR3DE). We sought to investigate the feasibility of both methods in patients with univentricular hearts and to compare them, including hemodynamic changes.<h4>Methods</h4>We studied 19 patients (age 2-29 years). PVR3DE and PVRCond were assessed under baseline conditions and stimulation with dobutamine.<h4>Results</h4>Obtaining PVR3DE was successful in all patients. Obtaining PVRCond was possible in 15 patients during baseline (79%) and in 12 patients under dobutamine (63%). Both methods showed that end-systolic elastance (Ees) and arterial elastance (Ea) increased under dobutamine and that Tau showed a statistically significant decrease. Intraclass correlation (95% confidence interval) showed moderate to good agreement between methods: Ees: 0.873 (0.711-0.945), Ea: 0.709 (0.336-0.873), Tau: 0.867 (0.697-0.942). Bland-Altman analyses showed an acceptable bias with wider limits of agreement: Ees: 1.63 mmHg/ml (-3.83-7.08 mmHg/ml), Ea: 0.53 mmHg/ml (-5.23-6.28 mmHg/ml), Tau: -0,76 ms (-10.73-9.21 ms).<h4>Conclusion</h4>Changes of PVR-specific parameters under dobutamine stimulation were reflected in the same way by both methods. However, the absolute values for these parameters could vary between methods and, therefore, methods are not interchangeable. Obtaining PVR3DE in a single ventricle was easier, faster and more successful than PVRCond. PVR3DE provides a promising and needed alternative to the conductance technology for the assessment of cardiac function in univentricular hearts.https://doi.org/10.1371/journal.pone.0246031
collection DOAJ
language English
format Article
sources DOAJ
author Katharina Linden
Christian Winkler
Johannes Breuer
Ulrike Herberg
spellingShingle Katharina Linden
Christian Winkler
Johannes Breuer
Ulrike Herberg
Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
PLoS ONE
author_facet Katharina Linden
Christian Winkler
Johannes Breuer
Ulrike Herberg
author_sort Katharina Linden
title Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
title_short Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
title_full Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
title_fullStr Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
title_full_unstemmed Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.
title_sort assessment of pressure-volume relations in univentricular hearts: comparison of obtainment by real-time 3d echocardiography and mini pressure-wire with conductance technology.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2021-01-01
description <h4>Objectives</h4>The gold standard to obtain pressure-volume relations (PVR) of the heart, the conductance technology (PVRCond), is rarely used in children. PVR can also be obtained by 3D-echocardiography volume data combined with simultaneously measured pressure data by a mini pressure-wire (PVR3DE). We sought to investigate the feasibility of both methods in patients with univentricular hearts and to compare them, including hemodynamic changes.<h4>Methods</h4>We studied 19 patients (age 2-29 years). PVR3DE and PVRCond were assessed under baseline conditions and stimulation with dobutamine.<h4>Results</h4>Obtaining PVR3DE was successful in all patients. Obtaining PVRCond was possible in 15 patients during baseline (79%) and in 12 patients under dobutamine (63%). Both methods showed that end-systolic elastance (Ees) and arterial elastance (Ea) increased under dobutamine and that Tau showed a statistically significant decrease. Intraclass correlation (95% confidence interval) showed moderate to good agreement between methods: Ees: 0.873 (0.711-0.945), Ea: 0.709 (0.336-0.873), Tau: 0.867 (0.697-0.942). Bland-Altman analyses showed an acceptable bias with wider limits of agreement: Ees: 1.63 mmHg/ml (-3.83-7.08 mmHg/ml), Ea: 0.53 mmHg/ml (-5.23-6.28 mmHg/ml), Tau: -0,76 ms (-10.73-9.21 ms).<h4>Conclusion</h4>Changes of PVR-specific parameters under dobutamine stimulation were reflected in the same way by both methods. However, the absolute values for these parameters could vary between methods and, therefore, methods are not interchangeable. Obtaining PVR3DE in a single ventricle was easier, faster and more successful than PVRCond. PVR3DE provides a promising and needed alternative to the conductance technology for the assessment of cardiac function in univentricular hearts.
url https://doi.org/10.1371/journal.pone.0246031
work_keys_str_mv AT katharinalinden assessmentofpressurevolumerelationsinuniventricularheartscomparisonofobtainmentbyrealtime3dechocardiographyandminipressurewirewithconductancetechnology
AT christianwinkler assessmentofpressurevolumerelationsinuniventricularheartscomparisonofobtainmentbyrealtime3dechocardiographyandminipressurewirewithconductancetechnology
AT johannesbreuer assessmentofpressurevolumerelationsinuniventricularheartscomparisonofobtainmentbyrealtime3dechocardiographyandminipressurewirewithconductancetechnology
AT ulrikeherberg assessmentofpressurevolumerelationsinuniventricularheartscomparisonofobtainmentbyrealtime3dechocardiographyandminipressurewirewithconductancetechnology
_version_ 1721247891383648256