Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool

Objective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound. Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound...

Full description

Bibliographic Details
Main Authors: David L. Murphy, Stephanie H. Oberfoell, Stacy A. Trent, Andrew J. French, Daniel J. Kim, David B. Richards
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-06-01
Series:Journal of Medical Ultrasound
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0929644117300036
id doaj-a4cdabcb4fb6424ea48a0129c90e016c
record_format Article
spelling doaj-a4cdabcb4fb6424ea48a0129c90e016c2020-11-24T21:35:18ZengWolters Kluwer Medknow PublicationsJournal of Medical Ultrasound0929-64412017-06-012529610010.1016/j.jmu.2017.01.003Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational ToolDavid L. Murphy0Stephanie H. Oberfoell1Stacy A. Trent2Andrew J. French3Daniel J. Kim4David B. Richards5University of Colorado, Denver School of Medicine, Aurora, CO, USADenver Health Residency in Emergency Medicine, Denver, CO, USAUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAUniversity of British Columbia, Department of Emergency Medicine, Vancouver, BC, CanadaUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAObjective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound. Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound fellowship-trained EM attending physicians. Participants performed optic nerve sheath diameter (ONSD) measurements on five in vivo and five phantom ocular ultrasound images and rated the realism of each image on a 5-point Likert scale. Chi-square analysis was performed to evaluate the subjective “realness” of in vivo and phantom images. Results: Sixty-one participants performed ONSD measurements. Mean Likert scale values were 3.43 (95% confidence interval: 3.31–3.55) for in vivo images and 3.41 (95% confidence interval: 3.28–3.54) for phantom images. There was no statistical difference in subjective “realness” between in vivo and phantom ONSD ultrasound images among EM residents. Ultrasound fellowship-trained EM attending physicians aptly differentiated between in vivo (p<0.01) and phantom (p<0.01) images, as compared with EM residents. Conclusion: Our ocular phantom simulates in vivo posterior ocular anatomy. EM resident physicians found the phantom indistinguishable from in vivo images. Our ONS model provides an inexpensive and realistic educational tool to teach bedside ONSD sonography.http://www.sciencedirect.com/science/article/pii/S0929644117300036emergency medicineocular ultrasoundoptic nerve sheath diameterultrasound phantom
collection DOAJ
language English
format Article
sources DOAJ
author David L. Murphy
Stephanie H. Oberfoell
Stacy A. Trent
Andrew J. French
Daniel J. Kim
David B. Richards
spellingShingle David L. Murphy
Stephanie H. Oberfoell
Stacy A. Trent
Andrew J. French
Daniel J. Kim
David B. Richards
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
Journal of Medical Ultrasound
emergency medicine
ocular ultrasound
optic nerve sheath diameter
ultrasound phantom
author_facet David L. Murphy
Stephanie H. Oberfoell
Stacy A. Trent
Andrew J. French
Daniel J. Kim
David B. Richards
author_sort David L. Murphy
title Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
title_short Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
title_full Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
title_fullStr Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
title_full_unstemmed Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
title_sort validation of a low-cost optic nerve sheath ultrasound phantom: an educational tool
publisher Wolters Kluwer Medknow Publications
series Journal of Medical Ultrasound
issn 0929-6441
publishDate 2017-06-01
description Objective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound. Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound fellowship-trained EM attending physicians. Participants performed optic nerve sheath diameter (ONSD) measurements on five in vivo and five phantom ocular ultrasound images and rated the realism of each image on a 5-point Likert scale. Chi-square analysis was performed to evaluate the subjective “realness” of in vivo and phantom images. Results: Sixty-one participants performed ONSD measurements. Mean Likert scale values were 3.43 (95% confidence interval: 3.31–3.55) for in vivo images and 3.41 (95% confidence interval: 3.28–3.54) for phantom images. There was no statistical difference in subjective “realness” between in vivo and phantom ONSD ultrasound images among EM residents. Ultrasound fellowship-trained EM attending physicians aptly differentiated between in vivo (p<0.01) and phantom (p<0.01) images, as compared with EM residents. Conclusion: Our ocular phantom simulates in vivo posterior ocular anatomy. EM resident physicians found the phantom indistinguishable from in vivo images. Our ONS model provides an inexpensive and realistic educational tool to teach bedside ONSD sonography.
topic emergency medicine
ocular ultrasound
optic nerve sheath diameter
ultrasound phantom
url http://www.sciencedirect.com/science/article/pii/S0929644117300036
work_keys_str_mv AT davidlmurphy validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
AT stephaniehoberfoell validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
AT stacyatrent validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
AT andrewjfrench validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
AT danieljkim validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
AT davidbrichards validationofalowcostopticnervesheathultrasoundphantomaneducationaltool
_version_ 1725945602859073536