Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool
Objective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound. Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2017-06-01
|
Series: | Journal of Medical Ultrasound |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S0929644117300036 |
id |
doaj-a4cdabcb4fb6424ea48a0129c90e016c |
---|---|
record_format |
Article |
spelling |
doaj-a4cdabcb4fb6424ea48a0129c90e016c2020-11-24T21:35:18ZengWolters Kluwer Medknow PublicationsJournal of Medical Ultrasound0929-64412017-06-012529610010.1016/j.jmu.2017.01.003Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational ToolDavid L. Murphy0Stephanie H. Oberfoell1Stacy A. Trent2Andrew J. French3Daniel J. Kim4David B. Richards5University of Colorado, Denver School of Medicine, Aurora, CO, USADenver Health Residency in Emergency Medicine, Denver, CO, USAUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAUniversity of British Columbia, Department of Emergency Medicine, Vancouver, BC, CanadaUniversity of Colorado, Denver School of Medicine, Aurora, CO, USAObjective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound. Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound fellowship-trained EM attending physicians. Participants performed optic nerve sheath diameter (ONSD) measurements on five in vivo and five phantom ocular ultrasound images and rated the realism of each image on a 5-point Likert scale. Chi-square analysis was performed to evaluate the subjective “realness” of in vivo and phantom images. Results: Sixty-one participants performed ONSD measurements. Mean Likert scale values were 3.43 (95% confidence interval: 3.31–3.55) for in vivo images and 3.41 (95% confidence interval: 3.28–3.54) for phantom images. There was no statistical difference in subjective “realness” between in vivo and phantom ONSD ultrasound images among EM residents. Ultrasound fellowship-trained EM attending physicians aptly differentiated between in vivo (p<0.01) and phantom (p<0.01) images, as compared with EM residents. Conclusion: Our ocular phantom simulates in vivo posterior ocular anatomy. EM resident physicians found the phantom indistinguishable from in vivo images. Our ONS model provides an inexpensive and realistic educational tool to teach bedside ONSD sonography.http://www.sciencedirect.com/science/article/pii/S0929644117300036emergency medicineocular ultrasoundoptic nerve sheath diameterultrasound phantom |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
David L. Murphy Stephanie H. Oberfoell Stacy A. Trent Andrew J. French Daniel J. Kim David B. Richards |
spellingShingle |
David L. Murphy Stephanie H. Oberfoell Stacy A. Trent Andrew J. French Daniel J. Kim David B. Richards Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool Journal of Medical Ultrasound emergency medicine ocular ultrasound optic nerve sheath diameter ultrasound phantom |
author_facet |
David L. Murphy Stephanie H. Oberfoell Stacy A. Trent Andrew J. French Daniel J. Kim David B. Richards |
author_sort |
David L. Murphy |
title |
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool |
title_short |
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool |
title_full |
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool |
title_fullStr |
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool |
title_full_unstemmed |
Validation of a Low-cost Optic Nerve Sheath Ultrasound Phantom: An Educational Tool |
title_sort |
validation of a low-cost optic nerve sheath ultrasound phantom: an educational tool |
publisher |
Wolters Kluwer Medknow Publications |
series |
Journal of Medical Ultrasound |
issn |
0929-6441 |
publishDate |
2017-06-01 |
description |
Objective: To validate an ocular phantom as a realistic educational tool utilizing in vivo and phantom optic nerve sheath (ONS) images obtained by ultrasound.
Methods: This prospective study enrolled 51 resident physicians from the Denver Health Residency in Emergency Medicine (EM) and 10 ultrasound fellowship-trained EM attending physicians. Participants performed optic nerve sheath diameter (ONSD) measurements on five in vivo and five phantom ocular ultrasound images and rated the realism of each image on a 5-point Likert scale. Chi-square analysis was performed to evaluate the subjective “realness” of in vivo and phantom images.
Results: Sixty-one participants performed ONSD measurements. Mean Likert scale values were 3.43 (95% confidence interval: 3.31–3.55) for in vivo images and 3.41 (95% confidence interval: 3.28–3.54) for phantom images. There was no statistical difference in subjective “realness” between in vivo and phantom ONSD ultrasound images among EM residents. Ultrasound fellowship-trained EM attending physicians aptly differentiated between in vivo (p<0.01) and phantom (p<0.01) images, as compared with EM residents.
Conclusion: Our ocular phantom simulates in vivo posterior ocular anatomy. EM resident physicians found the phantom indistinguishable from in vivo images. Our ONS model provides an inexpensive and realistic educational tool to teach bedside ONSD sonography. |
topic |
emergency medicine ocular ultrasound optic nerve sheath diameter ultrasound phantom |
url |
http://www.sciencedirect.com/science/article/pii/S0929644117300036 |
work_keys_str_mv |
AT davidlmurphy validationofalowcostopticnervesheathultrasoundphantomaneducationaltool AT stephaniehoberfoell validationofalowcostopticnervesheathultrasoundphantomaneducationaltool AT stacyatrent validationofalowcostopticnervesheathultrasoundphantomaneducationaltool AT andrewjfrench validationofalowcostopticnervesheathultrasoundphantomaneducationaltool AT danieljkim validationofalowcostopticnervesheathultrasoundphantomaneducationaltool AT davidbrichards validationofalowcostopticnervesheathultrasoundphantomaneducationaltool |