Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality

In 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science and the power  company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over the course of several years measurements were carried out at 59 points of the distribution sys...

Full description

Bibliographic Details
Main Authors: Petr Krejci, Pavel Santarius, Radomir Gono, Zdenek Brunclik
Format: Article
Language:English
Published: EEEIC International Publishing 2016-08-01
Series:Transactions on Environment and Electrical Engineering
Online Access:https://teee.eu/index.php/TEEE/article/view/37
id doaj-a498cdd07b78409f88688778e4ee9ed8
record_format Article
spelling doaj-a498cdd07b78409f88688778e4ee9ed82020-11-25T01:10:08ZengEEEIC International PublishingTransactions on Environment and Electrical Engineering2450-57302016-08-01131810.22149/teee.v1i3.3715Long-Term Monitoring of Flicker and Some Other Parameters of Voltage QualityPetr Krejci0Pavel Santarius1Radomir Gono2Zdenek Brunclik3VSB - Technical University of OstravaVSB - Technical University of OstravaVSB - Technical University of OstravaCzech Power CompanyIn 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science and the power  company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over the course of several years measurements were carried out at 59 points of the distribution system at a low voltage (LV) level and their power supply nodes at medium voltage (MV) and high voltage (HV) levels, which constituted more than 100 measured points. The measurements continued until 2012 (with a one-year break in 2009) and with a total scope of five cycles of three-year measurements. The last phase of the measurements was focused, inter alia, on the evaluation of 15th and 21st voltage harmonics. From 2013, the cooperation focused again on monitoring flicker in localities with the occurrence of elevated levels of this voltage quality parameter. At these sites, the monitoring of flicker was carried out for two weeks in spring and autumn for a period of three years. The basis for evaluating the quality parameters is the standard EN 50160.https://teee.eu/index.php/TEEE/article/view/37
collection DOAJ
language English
format Article
sources DOAJ
author Petr Krejci
Pavel Santarius
Radomir Gono
Zdenek Brunclik
spellingShingle Petr Krejci
Pavel Santarius
Radomir Gono
Zdenek Brunclik
Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
Transactions on Environment and Electrical Engineering
author_facet Petr Krejci
Pavel Santarius
Radomir Gono
Zdenek Brunclik
author_sort Petr Krejci
title Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
title_short Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
title_full Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
title_fullStr Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
title_full_unstemmed Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality
title_sort long-term monitoring of flicker and some other parameters of voltage quality
publisher EEEIC International Publishing
series Transactions on Environment and Electrical Engineering
issn 2450-5730
publishDate 2016-08-01
description In 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science and the power  company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over the course of several years measurements were carried out at 59 points of the distribution system at a low voltage (LV) level and their power supply nodes at medium voltage (MV) and high voltage (HV) levels, which constituted more than 100 measured points. The measurements continued until 2012 (with a one-year break in 2009) and with a total scope of five cycles of three-year measurements. The last phase of the measurements was focused, inter alia, on the evaluation of 15th and 21st voltage harmonics. From 2013, the cooperation focused again on monitoring flicker in localities with the occurrence of elevated levels of this voltage quality parameter. At these sites, the monitoring of flicker was carried out for two weeks in spring and autumn for a period of three years. The basis for evaluating the quality parameters is the standard EN 50160.
url https://teee.eu/index.php/TEEE/article/view/37
work_keys_str_mv AT petrkrejci longtermmonitoringofflickerandsomeotherparametersofvoltagequality
AT pavelsantarius longtermmonitoringofflickerandsomeotherparametersofvoltagequality
AT radomirgono longtermmonitoringofflickerandsomeotherparametersofvoltagequality
AT zdenekbrunclik longtermmonitoringofflickerandsomeotherparametersofvoltagequality
_version_ 1725176674132164608