Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation

Introduction: The current study aimed to compare linear accelerator-based three-dimensional conformal radiotherapy (Linac-3DCRT) technique with different techniques of the Radixact-X9 for the treatment of craniospinal irradiation (CSI). Material and Methods: Following a retrospective design, 22 CSI...

Full description

Bibliographic Details
Main Authors: Brijesh Goswami, Rakesh Jain, Suresh Yadav, Sunil Kumar, Saji Oommen, Sapna Manocha, Ganesh Jadav
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2021-05-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:https://ijmp.mums.ac.ir/article_15925_579c1a53d990830f44b72be66e2619df.pdf
id doaj-a3fb6953337549928fbdbfebd2c96167
record_format Article
spelling doaj-a3fb6953337549928fbdbfebd2c961672021-05-10T07:10:40ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722021-05-0118316417010.22038/ijmp.2020.45574.171215925Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal IrradiationBrijesh Goswami0Rakesh Jain1Suresh Yadav2Sunil Kumar3Saji Oommen4Sapna Manocha5Ganesh Jadav61. Department of Radiotherapy, Indraprastha Apollo Hospital, New Delhi-110076, India 2. Department of Physics, Shobhit Institute of Engineering & Technology, Meerut, Uttar Pradesh-250110, IndiaDepartment of Physics, Shobhit Institute of Engineering & Technology, Meerut, Uttar Pradesh-250110, IndiaDepartment of Radiotherapy, Gandhi Medical College, Bhopal-462001 (M.P.), IndiaDepartment of Radiotherapy, Indraprastha Apollo Hospital, New Delhi-110076, IndiaDepartment of Radiotherapy, Indraprastha Apollo Hospital, New Delhi-110076, IndiaDepartment of Radiotherapy, Indraprastha Apollo Hospital, New Delhi-110076, IndiaDepartment of Radiotherapy, Indraprastha Apollo Hospital, New Delhi-110076, IndiaIntroduction: The current study aimed to compare linear accelerator-based three-dimensional conformal radiotherapy (Linac-3DCRT) technique with different techniques of the Radixact-X9 for the treatment of craniospinal irradiation (CSI). Material and Methods: Following a retrospective design, 22 CSI patients (Medulloblastoma) treated with Linac-3DCRT using the Novalis-Tx unit were selected for analysis. For each patient plan, additional sets of plans were generated using Helical, Direct-3DCRT, and Direct-intensity-modulated radiotherapy (Direct-IMRT) techniques of the Radixact-X9 unit. The dose prescription for brain planning target volume (brain PTV) and spine PTV were 36 Gy in 20 fractions and kept the same for all techniques. Planning time, patient setup time, homogeneity index (HI), and different dose-volume parameters for both PTV and organs at risk (OARs) were evaluated for comparison. Results: The Radixact-X9-Helical technique can generate a plan in a more comparable and better manner in respect of maximum and minimum doses for most of the organs. The Radixact-X9-Helical technique resulted in better PTV homogeneity in comparison with Linac-3DCRT, Radixact-X9-Direct-3DCRT, and Radixact-X9-Direct-IMRT. The values of HI were 3.57±0.77, 17.37±1.44, 8.15±1.02, and 8.62±0.98, respectively. Conclusion: Not only administration of the Radixact-X9-Helical treatment technique is easier, but also can generate a better homogeneous plan than other treatment techniques like 3DCRT and IMRT regarding different parameters for comparisons like dose-volume received by OARs, patient setup time, move isocenter, and many more. So it can be an integral part of the radiotherapy department, according to their clinical needs like shorter treatment time with good sparing of critical OARs.https://ijmp.mums.ac.ir/article_15925_579c1a53d990830f44b72be66e2619df.pdfthreedimensional conformal radiotherapy helical intensitymodulated radiotherapy linear accelerator craniospinal irradiation
collection DOAJ
language English
format Article
sources DOAJ
author Brijesh Goswami
Rakesh Jain
Suresh Yadav
Sunil Kumar
Saji Oommen
Sapna Manocha
Ganesh Jadav
spellingShingle Brijesh Goswami
Rakesh Jain
Suresh Yadav
Sunil Kumar
Saji Oommen
Sapna Manocha
Ganesh Jadav
Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
Iranian Journal of Medical Physics
three
dimensional conformal radiotherapy helical intensity
modulated radiotherapy linear accelerator craniospinal irradiation
author_facet Brijesh Goswami
Rakesh Jain
Suresh Yadav
Sunil Kumar
Saji Oommen
Sapna Manocha
Ganesh Jadav
author_sort Brijesh Goswami
title Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
title_short Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
title_full Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
title_fullStr Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
title_full_unstemmed Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
title_sort comparison of treatment planning parameters of different radiotherapy techniques for craniospinal irradiation
publisher Mashhad University of Medical Sciences
series Iranian Journal of Medical Physics
issn 2345-3672
2345-3672
publishDate 2021-05-01
description Introduction: The current study aimed to compare linear accelerator-based three-dimensional conformal radiotherapy (Linac-3DCRT) technique with different techniques of the Radixact-X9 for the treatment of craniospinal irradiation (CSI). Material and Methods: Following a retrospective design, 22 CSI patients (Medulloblastoma) treated with Linac-3DCRT using the Novalis-Tx unit were selected for analysis. For each patient plan, additional sets of plans were generated using Helical, Direct-3DCRT, and Direct-intensity-modulated radiotherapy (Direct-IMRT) techniques of the Radixact-X9 unit. The dose prescription for brain planning target volume (brain PTV) and spine PTV were 36 Gy in 20 fractions and kept the same for all techniques. Planning time, patient setup time, homogeneity index (HI), and different dose-volume parameters for both PTV and organs at risk (OARs) were evaluated for comparison. Results: The Radixact-X9-Helical technique can generate a plan in a more comparable and better manner in respect of maximum and minimum doses for most of the organs. The Radixact-X9-Helical technique resulted in better PTV homogeneity in comparison with Linac-3DCRT, Radixact-X9-Direct-3DCRT, and Radixact-X9-Direct-IMRT. The values of HI were 3.57±0.77, 17.37±1.44, 8.15±1.02, and 8.62±0.98, respectively. Conclusion: Not only administration of the Radixact-X9-Helical treatment technique is easier, but also can generate a better homogeneous plan than other treatment techniques like 3DCRT and IMRT regarding different parameters for comparisons like dose-volume received by OARs, patient setup time, move isocenter, and many more. So it can be an integral part of the radiotherapy department, according to their clinical needs like shorter treatment time with good sparing of critical OARs.
topic three
dimensional conformal radiotherapy helical intensity
modulated radiotherapy linear accelerator craniospinal irradiation
url https://ijmp.mums.ac.ir/article_15925_579c1a53d990830f44b72be66e2619df.pdf
work_keys_str_mv AT brijeshgoswami comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT rakeshjain comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT sureshyadav comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT sunilkumar comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT sajioommen comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT sapnamanocha comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
AT ganeshjadav comparisonoftreatmentplanningparametersofdifferentradiotherapytechniquesforcraniospinalirradiation
_version_ 1721453524350402560