An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations

The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the pa...

Full description

Bibliographic Details
Main Authors: Aushiq Ali Memon, Kimmo Kauhaniemi
Format: Article
Language:English
Published: MDPI AG 2020-10-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/20/5316
id doaj-a3cfe9c71b74434dbfae4b46bbae32cf
record_format Article
spelling doaj-a3cfe9c71b74434dbfae4b46bbae32cf2020-11-25T02:41:57ZengMDPI AGEnergies1996-10732020-10-01135316531610.3390/en13205316An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline SimulationsAushiq Ali Memon0Kimmo Kauhaniemi1School of Technology and Innovations, University of Vaasa, Wolffintie 34, FI-65200 Vaasa, FinlandSchool of Technology and Innovations, University of Vaasa, Wolffintie 34, FI-65200 Vaasa, FinlandThe IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the paper is to utilize the existing low-voltage ride through characteristic of distributed generators (DGs) with a reactive power supply during faults and communication between intelligent electronic devices (IEDs) at different locations for adaptive overcurrent protection. The adaptive overcurrent IEDs detect the faults with two different preplanned settings groups: lower settings for the islanded mode and higher settings for the grid-connected mode considering limited fault contributions from the converter-based DGs. Setting groups are changed to lower values quickly using the circuit breaker status signal (XCBR) after loss-of-mains, loss-of-DG or islanding is detected. The methods of fault detection and isolation for two different kinds of communication-based IEDs (adaptive/nonadaptive) are explained for three-phase faults at two different locations. The communication-based IEDs take decisions in a decentralized manner, using information about the circuit breaker status, fault detection and current magnitude comparison signals obtained from other IEDs. However, the developed algorithm can also be implemented with the centralized system. An adaptive overcurrent protection algorithm was evaluated with PSCAD (Power Systems Computer Aided Design) simulations, and results were found to be effective for the considered fault cases.https://www.mdpi.com/1996-1073/13/20/5316AC microgridadaptive protectionIEC 61850 GOOSE protocolsubstation automation
collection DOAJ
language English
format Article
sources DOAJ
author Aushiq Ali Memon
Kimmo Kauhaniemi
spellingShingle Aushiq Ali Memon
Kimmo Kauhaniemi
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
Energies
AC microgrid
adaptive protection
IEC 61850 GOOSE protocol
substation automation
author_facet Aushiq Ali Memon
Kimmo Kauhaniemi
author_sort Aushiq Ali Memon
title An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
title_short An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
title_full An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
title_fullStr An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
title_full_unstemmed An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
title_sort adaptive protection for radial ac microgrid using iec 61850 communication standard: algorithm proposal using offline simulations
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2020-10-01
description The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the paper is to utilize the existing low-voltage ride through characteristic of distributed generators (DGs) with a reactive power supply during faults and communication between intelligent electronic devices (IEDs) at different locations for adaptive overcurrent protection. The adaptive overcurrent IEDs detect the faults with two different preplanned settings groups: lower settings for the islanded mode and higher settings for the grid-connected mode considering limited fault contributions from the converter-based DGs. Setting groups are changed to lower values quickly using the circuit breaker status signal (XCBR) after loss-of-mains, loss-of-DG or islanding is detected. The methods of fault detection and isolation for two different kinds of communication-based IEDs (adaptive/nonadaptive) are explained for three-phase faults at two different locations. The communication-based IEDs take decisions in a decentralized manner, using information about the circuit breaker status, fault detection and current magnitude comparison signals obtained from other IEDs. However, the developed algorithm can also be implemented with the centralized system. An adaptive overcurrent protection algorithm was evaluated with PSCAD (Power Systems Computer Aided Design) simulations, and results were found to be effective for the considered fault cases.
topic AC microgrid
adaptive protection
IEC 61850 GOOSE protocol
substation automation
url https://www.mdpi.com/1996-1073/13/20/5316
work_keys_str_mv AT aushiqalimemon anadaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations
AT kimmokauhaniemi anadaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations
AT aushiqalimemon adaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations
AT kimmokauhaniemi adaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations
_version_ 1724776303972843520