An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations
The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the pa...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-10-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/13/20/5316 |
id |
doaj-a3cfe9c71b74434dbfae4b46bbae32cf |
---|---|
record_format |
Article |
spelling |
doaj-a3cfe9c71b74434dbfae4b46bbae32cf2020-11-25T02:41:57ZengMDPI AGEnergies1996-10732020-10-01135316531610.3390/en13205316An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline SimulationsAushiq Ali Memon0Kimmo Kauhaniemi1School of Technology and Innovations, University of Vaasa, Wolffintie 34, FI-65200 Vaasa, FinlandSchool of Technology and Innovations, University of Vaasa, Wolffintie 34, FI-65200 Vaasa, FinlandThe IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the paper is to utilize the existing low-voltage ride through characteristic of distributed generators (DGs) with a reactive power supply during faults and communication between intelligent electronic devices (IEDs) at different locations for adaptive overcurrent protection. The adaptive overcurrent IEDs detect the faults with two different preplanned settings groups: lower settings for the islanded mode and higher settings for the grid-connected mode considering limited fault contributions from the converter-based DGs. Setting groups are changed to lower values quickly using the circuit breaker status signal (XCBR) after loss-of-mains, loss-of-DG or islanding is detected. The methods of fault detection and isolation for two different kinds of communication-based IEDs (adaptive/nonadaptive) are explained for three-phase faults at two different locations. The communication-based IEDs take decisions in a decentralized manner, using information about the circuit breaker status, fault detection and current magnitude comparison signals obtained from other IEDs. However, the developed algorithm can also be implemented with the centralized system. An adaptive overcurrent protection algorithm was evaluated with PSCAD (Power Systems Computer Aided Design) simulations, and results were found to be effective for the considered fault cases.https://www.mdpi.com/1996-1073/13/20/5316AC microgridadaptive protectionIEC 61850 GOOSE protocolsubstation automation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Aushiq Ali Memon Kimmo Kauhaniemi |
spellingShingle |
Aushiq Ali Memon Kimmo Kauhaniemi An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations Energies AC microgrid adaptive protection IEC 61850 GOOSE protocol substation automation |
author_facet |
Aushiq Ali Memon Kimmo Kauhaniemi |
author_sort |
Aushiq Ali Memon |
title |
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations |
title_short |
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations |
title_full |
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations |
title_fullStr |
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations |
title_full_unstemmed |
An Adaptive Protection for Radial AC Microgrid Using IEC 61850 Communication Standard: Algorithm Proposal Using Offline Simulations |
title_sort |
adaptive protection for radial ac microgrid using iec 61850 communication standard: algorithm proposal using offline simulations |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2020-10-01 |
description |
The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC microgrid for adaptive protection. The focus of the paper is to utilize the existing low-voltage ride through characteristic of distributed generators (DGs) with a reactive power supply during faults and communication between intelligent electronic devices (IEDs) at different locations for adaptive overcurrent protection. The adaptive overcurrent IEDs detect the faults with two different preplanned settings groups: lower settings for the islanded mode and higher settings for the grid-connected mode considering limited fault contributions from the converter-based DGs. Setting groups are changed to lower values quickly using the circuit breaker status signal (XCBR) after loss-of-mains, loss-of-DG or islanding is detected. The methods of fault detection and isolation for two different kinds of communication-based IEDs (adaptive/nonadaptive) are explained for three-phase faults at two different locations. The communication-based IEDs take decisions in a decentralized manner, using information about the circuit breaker status, fault detection and current magnitude comparison signals obtained from other IEDs. However, the developed algorithm can also be implemented with the centralized system. An adaptive overcurrent protection algorithm was evaluated with PSCAD (Power Systems Computer Aided Design) simulations, and results were found to be effective for the considered fault cases. |
topic |
AC microgrid adaptive protection IEC 61850 GOOSE protocol substation automation |
url |
https://www.mdpi.com/1996-1073/13/20/5316 |
work_keys_str_mv |
AT aushiqalimemon anadaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations AT kimmokauhaniemi anadaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations AT aushiqalimemon adaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations AT kimmokauhaniemi adaptiveprotectionforradialacmicrogridusingiec61850communicationstandardalgorithmproposalusingofflinesimulations |
_version_ |
1724776303972843520 |