Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów
The verification of simulation model of combined sewage system was presented in article. The model of sewage system functioning in Głogów was developed using SWMM 5.1 (Storm Water Management Model) software. It was calibrated based on the results of field studies from the years 2011–13, while the pr...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Sciendo
2018-09-01
|
Series: | Civil and Environmental Engineering Reports |
Subjects: | |
Online Access: | https://doi.org/10.2478/ceer-2018-0039 |
id |
doaj-a3b7318f8018410db4039800e76cf6f4 |
---|---|
record_format |
Article |
spelling |
doaj-a3b7318f8018410db4039800e76cf6f42021-09-06T19:22:02ZengSciendoCivil and Environmental Engineering Reports2080-51872450-85942018-09-0128311112010.2478/ceer-2018-0039ceer-2018-0039Verification of the Simulation Model Based on the Example of Combined Sewage System in GłogówNowogoński Ireneusz0University of Zielona Gora, PolandThe verification of simulation model of combined sewage system was presented in article. The model of sewage system functioning in Głogów was developed using SWMM 5.1 (Storm Water Management Model) software. It was calibrated based on the results of field studies from the years 2011–13, while the properness of its activity was verified for the results of measurements carried out in 2014. The verification of the model showed acceptable discrepancies between the measured and simulated values of flow rates. Factors which caused differences were indicated and, on the basis of this, conclusions pertaining to further studies were formulated.https://doi.org/10.2478/ceer-2018-0039combined sewage systemrainfall-runoff phenomenasimulation model |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nowogoński Ireneusz |
spellingShingle |
Nowogoński Ireneusz Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów Civil and Environmental Engineering Reports combined sewage system rainfall-runoff phenomena simulation model |
author_facet |
Nowogoński Ireneusz |
author_sort |
Nowogoński Ireneusz |
title |
Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów |
title_short |
Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów |
title_full |
Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów |
title_fullStr |
Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów |
title_full_unstemmed |
Verification of the Simulation Model Based on the Example of Combined Sewage System in Głogów |
title_sort |
verification of the simulation model based on the example of combined sewage system in głogów |
publisher |
Sciendo |
series |
Civil and Environmental Engineering Reports |
issn |
2080-5187 2450-8594 |
publishDate |
2018-09-01 |
description |
The verification of simulation model of combined sewage system was presented in article. The model of sewage system functioning in Głogów was developed using SWMM 5.1 (Storm Water Management Model) software. It was calibrated based on the results of field studies from the years 2011–13, while the properness of its activity was verified for the results of measurements carried out in 2014. The verification of the model showed acceptable discrepancies between the measured and simulated values of flow rates. Factors which caused differences were indicated and, on the basis of this, conclusions pertaining to further studies were formulated. |
topic |
combined sewage system rainfall-runoff phenomena simulation model |
url |
https://doi.org/10.2478/ceer-2018-0039 |
work_keys_str_mv |
AT nowogonskiireneusz verificationofthesimulationmodelbasedontheexampleofcombinedsewagesystemingłogow |
_version_ |
1717772864094994432 |