Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases

Objective To explore the differences in measurement result of femoral neck shaft angle between anteroposterior X-ray film and 3-dimensional CT reconstruction image, and investigate the main related factors that lead to the differences. Methods The clinical data of 265 lower limbs from 265 patients...

Full description

Bibliographic Details
Main Authors: LIU Liming, LEI Kai, FAN Huaquan, CHEN Xin, YANG Liu, GUO Lin
Format: Article
Language:zho
Published: Editorial Office of Journal of Third Military Medical University 2020-11-01
Series:Di-san junyi daxue xuebao
Subjects:
Online Access:http://aammt.tmmu.edu.cn/Upload/rhtml/202006166.htm
id doaj-a2c1cc7f3198472b8c5a01bc83f2d7ed
record_format Article
spelling doaj-a2c1cc7f3198472b8c5a01bc83f2d7ed2021-05-30T01:03:57ZzhoEditorial Office of Journal of Third Military Medical UniversityDi-san junyi daxue xuebao1000-54042020-11-0142212134214010.16016/j.1000-5404.202006166Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases LIU Liming0LEI Kai1FAN Huaquan2CHEN Xin3YANG Liu4GUO Lin5Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Center of Joint Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China Objective To explore the differences in measurement result of femoral neck shaft angle between anteroposterior X-ray film and 3-dimensional CT reconstruction image, and investigate the main related factors that lead to the differences. Methods The clinical data of 265 lower limbs from 265 patients hospitalized in our center from August 2016 to June 2018 were retrospectively collected from the electronic medical record system of our hospital. The femoral neck shaft angle was measured on the anteroposterior X-ray films and 3-dimensional CT reconstruction images, and the difference was tested. Age, gender, BMI, left and right difference, hip-knee-ankle angle, femoral bowing angle, femoral torsion angle, mechanical lateral distal femoral angle and femoral shaft length were included to establish a statistical model to screen the most important factors leading to the difference. Finally, a control group and an experimental group were set up through the 1:1 propensity score matching to verify the the most important factors. Results The femoral neck shaft angle was (128.02±6.26)° on the anteroposterior X-ray films and (124.22±6.45)° on the 3-dimensional CT reconstruction images, and statistical difference was found between them (P < 0.001), with a difference greater than 3° (accounting for 56.6% of the patients). The established multiple linear regression model (P < 0.001, adjusted R2=0.747) showed that femoral torsion angle (standardized regression coefficient=-0.233, P < 0.001) was the most important factor of the difference. Conclusion There is a difference in the measurement result of femoral neck shaft angle between anteroposterior X-ray film and 3-dimensional CT reconstruction image. Femoral torsion angle is the most important factor. Larger femoral extorsion angle causes larger femoral neck shaft angle measured on the anteroposterior X-ray film.http://aammt.tmmu.edu.cn/Upload/rhtml/202006166.htmfemoral neck shaft anglefemoral torsion angle3-dimensional reconstruction imagex-ray film
collection DOAJ
language zho
format Article
sources DOAJ
author LIU Liming
LEI Kai
FAN Huaquan
CHEN Xin
YANG Liu
GUO Lin
spellingShingle LIU Liming
LEI Kai
FAN Huaquan
CHEN Xin
YANG Liu
GUO Lin
Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
Di-san junyi daxue xuebao
femoral neck shaft angle
femoral torsion angle
3-dimensional reconstruction image
x-ray film
author_facet LIU Liming
LEI Kai
FAN Huaquan
CHEN Xin
YANG Liu
GUO Lin
author_sort LIU Liming
title Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
title_short Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
title_full Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
title_fullStr Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
title_full_unstemmed Differences in femoral neck shaft angles between anteroposterior X-ray and 3-dimensional CT reconstruction images: report of 265 cases
title_sort differences in femoral neck shaft angles between anteroposterior x-ray and 3-dimensional ct reconstruction images: report of 265 cases
publisher Editorial Office of Journal of Third Military Medical University
series Di-san junyi daxue xuebao
issn 1000-5404
publishDate 2020-11-01
description Objective To explore the differences in measurement result of femoral neck shaft angle between anteroposterior X-ray film and 3-dimensional CT reconstruction image, and investigate the main related factors that lead to the differences. Methods The clinical data of 265 lower limbs from 265 patients hospitalized in our center from August 2016 to June 2018 were retrospectively collected from the electronic medical record system of our hospital. The femoral neck shaft angle was measured on the anteroposterior X-ray films and 3-dimensional CT reconstruction images, and the difference was tested. Age, gender, BMI, left and right difference, hip-knee-ankle angle, femoral bowing angle, femoral torsion angle, mechanical lateral distal femoral angle and femoral shaft length were included to establish a statistical model to screen the most important factors leading to the difference. Finally, a control group and an experimental group were set up through the 1:1 propensity score matching to verify the the most important factors. Results The femoral neck shaft angle was (128.02±6.26)° on the anteroposterior X-ray films and (124.22±6.45)° on the 3-dimensional CT reconstruction images, and statistical difference was found between them (P < 0.001), with a difference greater than 3° (accounting for 56.6% of the patients). The established multiple linear regression model (P < 0.001, adjusted R2=0.747) showed that femoral torsion angle (standardized regression coefficient=-0.233, P < 0.001) was the most important factor of the difference. Conclusion There is a difference in the measurement result of femoral neck shaft angle between anteroposterior X-ray film and 3-dimensional CT reconstruction image. Femoral torsion angle is the most important factor. Larger femoral extorsion angle causes larger femoral neck shaft angle measured on the anteroposterior X-ray film.
topic femoral neck shaft angle
femoral torsion angle
3-dimensional reconstruction image
x-ray film
url http://aammt.tmmu.edu.cn/Upload/rhtml/202006166.htm
work_keys_str_mv AT liuliming differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
AT leikai differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
AT fanhuaquan differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
AT chenxin differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
AT yangliu differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
AT guolin differencesinfemoralneckshaftanglesbetweenanteroposteriorxrayand3dimensionalctreconstructionimagesreportof265cases
_version_ 1721421228992888832