Optimization of key power loss for LLC circuits with planar transformer in high-frequency and high-power scenarios
An accurate power loss model, for the design of high-efficiency switching power supplies, is difficult to establish due to the complicated magnetic components where the power loss is hard to calculate. This paper proposed a multi-level power loss model of LLC circuits with a planar transformer of hi...
Main Authors: | Ziyi Ji, Fuhong Min, Yiping Dou, Ziqing Cao, Xinya Li |
---|---|
Format: | Article |
Language: | English |
Published: |
AIP Publishing LLC
2021-05-01
|
Series: | AIP Advances |
Online Access: | http://dx.doi.org/10.1063/5.0054159 |
Similar Items
-
Analysis and Circuit Design for High Efficiency LLC Resonant Switching Power Supply
by: Chien Lung, et al.
Published: (2012) -
Analysis and Circuit Design for High Efficient LLC Resonate Switching Power Supply
by: Hsien-Te Huang, et al.
Published: (2006) -
Optimization Design of Planar Transformer for High Frequency LLC Series Resonant Converters
by: Meng-Fan Lin, et al.
Published: (2018) -
Design of the High Efficiency LLC Power Converter
by: Chi-Tsung Liang, et al.
Published: (2008) -
Design and Implementation of a Novel Half -Turn Planar Transformer for High power Density LLC Resonant Converter
by: De-Jia Lu, et al.
Published: (2019)