Accuracy of Synovial Leukocyte and Polymorphonuclear Cell Count in Patients with Shoulder Prosthetic Joint Infection
<p class="p p-first-last" id="__p2">Joint aspiration in suspected infected implants is a validated diagnostic method in establishing the diagnosis of prosthetic joint infection (PJI). Cut-off values for synovial leukocyte counts and differentials are well described for pati...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Copernicus Publications
2018-11-01
|
Series: | Journal of Bone and Joint Infection |
Online Access: | https://jbji.copernicus.org/articles/3/245/2018/jbji-3-245-2018.pdf |
Summary: | <p class="p p-first-last" id="__p2">Joint aspiration in suspected infected implants is a validated diagnostic method in establishing the diagnosis of prosthetic joint infection (PJI). Cut-off values for synovial leukocyte counts and differentials are well described for patients with hip and knee PJI. In 19 failed shoulder implants, a leucocyte count of >12.2 G/L had a sensitivity and specificity of 92% and 100% respectively; A differential of >54% neutrophils had a sensitivity of 100 % and a specificity of 75%.</p> |
---|---|