Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers

In order to explore the influence mechanisms of ambient wind speed on the performance of indirect air-cooled system, SCAL indirect air-cooled towers of a 600MW supercritical unit was taken as an example, and the corresponding calculation model was established. By the ways of CFD numerical simulation...

Full description

Bibliographic Details
Format: Article
Language:zho
Published: The Northwestern Polytechnical University 2018-06-01
Series:Xibei Gongye Daxue Xuebao
Subjects:
Online Access:https://www.jnwpu.org/articles/jnwpu/pdf/2018/03/jnwpu2018363p456.pdf
id doaj-a1d4fbdf0f494d41be0ec3b7dcc06efe
record_format Article
spelling doaj-a1d4fbdf0f494d41be0ec3b7dcc06efe2021-05-02T19:19:49ZzhoThe Northwestern Polytechnical UniversityXibei Gongye Daxue Xuebao1000-27582609-71252018-06-0136345646310.1051/jnwpu/20183630456jnwpu2018363p456Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled TowersIn order to explore the influence mechanisms of ambient wind speed on the performance of indirect air-cooled system, SCAL indirect air-cooled towers of a 600MW supercritical unit was taken as an example, and the corresponding calculation model was established. By the ways of CFD numerical simulation and field test, the variations along with ambient velocity of airflow field inside and outside the tower were simulated and the thermal performance of those towers under different ambient velocity was studied. The results showed that, the outlet resistance of air-cooled tower increased in pace with ambient velocity. Both temperature field inside the tower and pressure field inside and outside the tower were influenced by the ambient velocity to a large extent, while flow trajectory of flue gas inside the tower was basically similar. Moreover, the trends and changing laws of performance parameters from the level of segments and the tower were achieved. The conclusions would be of some reference significance for the optimal operation and design of indirect air-cooled system.https://www.jnwpu.org/articles/jnwpu/pdf/2018/03/jnwpu2018363p456.pdfindirect air-cooled towernumerical simulationtest fieldambient velocitythermal performance
collection DOAJ
language zho
format Article
sources DOAJ
title Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
spellingShingle Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
Xibei Gongye Daxue Xuebao
indirect air-cooled tower
numerical simulation
test field
ambient velocity
thermal performance
title_short Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
title_full Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
title_fullStr Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
title_full_unstemmed Influence of Ambient Velocity on the Performance of SCAL Indirect Air-Cooled Towers
title_sort influence of ambient velocity on the performance of scal indirect air-cooled towers
publisher The Northwestern Polytechnical University
series Xibei Gongye Daxue Xuebao
issn 1000-2758
2609-7125
publishDate 2018-06-01
description In order to explore the influence mechanisms of ambient wind speed on the performance of indirect air-cooled system, SCAL indirect air-cooled towers of a 600MW supercritical unit was taken as an example, and the corresponding calculation model was established. By the ways of CFD numerical simulation and field test, the variations along with ambient velocity of airflow field inside and outside the tower were simulated and the thermal performance of those towers under different ambient velocity was studied. The results showed that, the outlet resistance of air-cooled tower increased in pace with ambient velocity. Both temperature field inside the tower and pressure field inside and outside the tower were influenced by the ambient velocity to a large extent, while flow trajectory of flue gas inside the tower was basically similar. Moreover, the trends and changing laws of performance parameters from the level of segments and the tower were achieved. The conclusions would be of some reference significance for the optimal operation and design of indirect air-cooled system.
topic indirect air-cooled tower
numerical simulation
test field
ambient velocity
thermal performance
url https://www.jnwpu.org/articles/jnwpu/pdf/2018/03/jnwpu2018363p456.pdf
_version_ 1721488550827917312