Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force

Abstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successful...

Full description

Bibliographic Details
Main Authors: Marina Arai, Seiji Fukamizu, Iwanari Kawamura, Satoshi Miyazawa, Rintaro Hojo, Harumizu Sakurada, Masayasu Hiraoka
Format: Article
Language:English
Published: Wiley 2018-04-01
Series:Journal of Arrhythmia
Subjects:
Online Access:https://doi.org/10.1002/joa3.12038
id doaj-a130b39a324e4430b582493c0bb3c320
record_format Article
spelling doaj-a130b39a324e4430b582493c0bb3c3202020-11-25T03:41:10ZengWileyJournal of Arrhythmia1880-42761883-21482018-04-0134220120310.1002/joa3.12038Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact forceMarina Arai0Seiji Fukamizu1Iwanari Kawamura2Satoshi Miyazawa3Rintaro Hojo4Harumizu Sakurada5Masayasu Hiraoka6Department of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanTokyo Metropolitan Health and Medical Treatment Corporation Ohkubo Hospital Shinjuku‐ku Tokyo JapanDepartment of Cardiovascular Diseases Tokyo Medical and Dental University Bunkyō Tokyo JapanAbstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.https://doi.org/10.1002/joa3.12038atrioventricular septumcontact forceintracardiac echocardiographyright atrium angiographyventricular premature complex
collection DOAJ
language English
format Article
sources DOAJ
author Marina Arai
Seiji Fukamizu
Iwanari Kawamura
Satoshi Miyazawa
Rintaro Hojo
Harumizu Sakurada
Masayasu Hiraoka
spellingShingle Marina Arai
Seiji Fukamizu
Iwanari Kawamura
Satoshi Miyazawa
Rintaro Hojo
Harumizu Sakurada
Masayasu Hiraoka
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
Journal of Arrhythmia
atrioventricular septum
contact force
intracardiac echocardiography
right atrium angiography
ventricular premature complex
author_facet Marina Arai
Seiji Fukamizu
Iwanari Kawamura
Satoshi Miyazawa
Rintaro Hojo
Harumizu Sakurada
Masayasu Hiraoka
author_sort Marina Arai
title Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
title_short Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
title_full Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
title_fullStr Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
title_full_unstemmed Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
title_sort successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
publisher Wiley
series Journal of Arrhythmia
issn 1880-4276
1883-2148
publishDate 2018-04-01
description Abstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.
topic atrioventricular septum
contact force
intracardiac echocardiography
right atrium angiography
ventricular premature complex
url https://doi.org/10.1002/joa3.12038
work_keys_str_mv AT marinaarai successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT seijifukamizu successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT iwanarikawamura successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT satoshimiyazawa successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT rintarohojo successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT harumizusakurada successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
AT masayasuhiraoka successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce
_version_ 1724531158385950720