Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force
Abstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successful...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-04-01
|
Series: | Journal of Arrhythmia |
Subjects: | |
Online Access: | https://doi.org/10.1002/joa3.12038 |
id |
doaj-a130b39a324e4430b582493c0bb3c320 |
---|---|
record_format |
Article |
spelling |
doaj-a130b39a324e4430b582493c0bb3c3202020-11-25T03:41:10ZengWileyJournal of Arrhythmia1880-42761883-21482018-04-0134220120310.1002/joa3.12038Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact forceMarina Arai0Seiji Fukamizu1Iwanari Kawamura2Satoshi Miyazawa3Rintaro Hojo4Harumizu Sakurada5Masayasu Hiraoka6Department of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanDepartment of Cardiology Tokyo Metropolitan Hiroo Hospital Shibuya‐ku Tokyo JapanTokyo Metropolitan Health and Medical Treatment Corporation Ohkubo Hospital Shinjuku‐ku Tokyo JapanDepartment of Cardiovascular Diseases Tokyo Medical and Dental University Bunkyō Tokyo JapanAbstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.https://doi.org/10.1002/joa3.12038atrioventricular septumcontact forceintracardiac echocardiographyright atrium angiographyventricular premature complex |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marina Arai Seiji Fukamizu Iwanari Kawamura Satoshi Miyazawa Rintaro Hojo Harumizu Sakurada Masayasu Hiraoka |
spellingShingle |
Marina Arai Seiji Fukamizu Iwanari Kawamura Satoshi Miyazawa Rintaro Hojo Harumizu Sakurada Masayasu Hiraoka Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force Journal of Arrhythmia atrioventricular septum contact force intracardiac echocardiography right atrium angiography ventricular premature complex |
author_facet |
Marina Arai Seiji Fukamizu Iwanari Kawamura Satoshi Miyazawa Rintaro Hojo Harumizu Sakurada Masayasu Hiraoka |
author_sort |
Marina Arai |
title |
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
title_short |
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
title_full |
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
title_fullStr |
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
title_full_unstemmed |
Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
title_sort |
successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force |
publisher |
Wiley |
series |
Journal of Arrhythmia |
issn |
1880-4276 1883-2148 |
publishDate |
2018-04-01 |
description |
Abstract The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS. |
topic |
atrioventricular septum contact force intracardiac echocardiography right atrium angiography ventricular premature complex |
url |
https://doi.org/10.1002/joa3.12038 |
work_keys_str_mv |
AT marinaarai successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT seijifukamizu successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT iwanarikawamura successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT satoshimiyazawa successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT rintarohojo successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT harumizusakurada successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce AT masayasuhiraoka successfulcatheterablationofventricularprematurecomplexesfromtherightatrialsideoftheatrioventricularseptumwithgoodcontactforce |
_version_ |
1724531158385950720 |