Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp

Objectives. To measure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Metho...

Full description

Bibliographic Details
Main Authors: Firdevs Kahvecioglu, Gül Tosun, Hayriye Esra Ülker
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:BioMed Research International
Online Access:http://dx.doi.org/10.1155/2016/5173805
id doaj-a0f49653832b428a8c12f91ff42184cc
record_format Article
spelling doaj-a0f49653832b428a8c12f91ff42184cc2020-11-24T22:43:25ZengHindawi LimitedBioMed Research International2314-61332314-61412016-01-01201610.1155/2016/51738055173805Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure LampFirdevs Kahvecioglu0Gül Tosun1Hayriye Esra Ülker2Department of Pediatric Dentistry, Faculty of Dentistry, Selcuk University, Konya, TurkeyDepartment of Pediatric Dentistry, Faculty of Dentistry, Selcuk University, Konya, TurkeyDepartment of Restorative Dentistry, Faculty of Dentistry, Selcuk University, Konya, TurkeyObjectives. To measure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Methods. Nonretentive class I cavities were prepared in extracted primary and permanent molars. Glass carbomer (GC) was placed in the cavity and set at 60°C for 60 sn using a special thermocure lamp. Resin-modified glass ionomer (RMGIC) and polyacid-modified composite resin (PMCR) were placed in the cavities and polymerized with an LED curing unit. Temperature increases during setting reactions were measured with a J-type thermocouple wire connected to a data logger. Data were examined using two-way analysis of variance and Tukey’s honestly significant difference tests. Results. The use of GC resulted in temperature changes of 5.17 ± 0.92°C and 5.32 ± 0.90°C in primary and permanent teeth, respectively (p>0.05). Temperature increases were greatest in the GC group, differing significantly from those in the PMCR group (p<0.05). Conclusion. Temperature increases during polymerization and setting reactions of the materials were below the critical value in all groups. No difference was observed between primary and permanent teeth, regardless of the material used.http://dx.doi.org/10.1155/2016/5173805
collection DOAJ
language English
format Article
sources DOAJ
author Firdevs Kahvecioglu
Gül Tosun
Hayriye Esra Ülker
spellingShingle Firdevs Kahvecioglu
Gül Tosun
Hayriye Esra Ülker
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
BioMed Research International
author_facet Firdevs Kahvecioglu
Gül Tosun
Hayriye Esra Ülker
author_sort Firdevs Kahvecioglu
title Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
title_short Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
title_full Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
title_fullStr Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
title_full_unstemmed Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
title_sort intrapulpal thermal changes during setting reaction of glass carbomer® using thermocure lamp
publisher Hindawi Limited
series BioMed Research International
issn 2314-6133
2314-6141
publishDate 2016-01-01
description Objectives. To measure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Methods. Nonretentive class I cavities were prepared in extracted primary and permanent molars. Glass carbomer (GC) was placed in the cavity and set at 60°C for 60 sn using a special thermocure lamp. Resin-modified glass ionomer (RMGIC) and polyacid-modified composite resin (PMCR) were placed in the cavities and polymerized with an LED curing unit. Temperature increases during setting reactions were measured with a J-type thermocouple wire connected to a data logger. Data were examined using two-way analysis of variance and Tukey’s honestly significant difference tests. Results. The use of GC resulted in temperature changes of 5.17 ± 0.92°C and 5.32 ± 0.90°C in primary and permanent teeth, respectively (p>0.05). Temperature increases were greatest in the GC group, differing significantly from those in the PMCR group (p<0.05). Conclusion. Temperature increases during polymerization and setting reactions of the materials were below the critical value in all groups. No difference was observed between primary and permanent teeth, regardless of the material used.
url http://dx.doi.org/10.1155/2016/5173805
work_keys_str_mv AT firdevskahvecioglu intrapulpalthermalchangesduringsettingreactionofglasscarbomerusingthermocurelamp
AT gultosun intrapulpalthermalchangesduringsettingreactionofglasscarbomerusingthermocurelamp
AT hayriyeesraulker intrapulpalthermalchangesduringsettingreactionofglasscarbomerusingthermocurelamp
_version_ 1725696084793098240