Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire

This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structur...

Full description

Bibliographic Details
Main Authors: Liu Yong Jun, Li Chao, Zhou When Jun
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20183803036
id doaj-a0ede0f860ae44b3972bddb89c71b75b
record_format Article
spelling doaj-a0ede0f860ae44b3972bddb89c71b75b2021-02-02T08:48:50ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01380303610.1051/e3sconf/20183803036e3sconf_icemee2018_03036Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard FireLiu Yong JunLi ChaoZhou When JunThis paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.https://doi.org/10.1051/e3sconf/20183803036
collection DOAJ
language English
format Article
sources DOAJ
author Liu Yong Jun
Li Chao
Zhou When Jun
spellingShingle Liu Yong Jun
Li Chao
Zhou When Jun
Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
E3S Web of Conferences
author_facet Liu Yong Jun
Li Chao
Zhou When Jun
author_sort Liu Yong Jun
title Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
title_short Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
title_full Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
title_fullStr Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
title_full_unstemmed Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire
title_sort numerical analysis on tensile properties of grout-filled splice sleeve rebars under iso 834 standard fire
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.
url https://doi.org/10.1051/e3sconf/20183803036
work_keys_str_mv AT liuyongjun numericalanalysisontensilepropertiesofgroutfilledsplicesleeverebarsunderiso834standardfire
AT lichao numericalanalysisontensilepropertiesofgroutfilledsplicesleeverebarsunderiso834standardfire
AT zhouwhenjun numericalanalysisontensilepropertiesofgroutfilledsplicesleeverebarsunderiso834standardfire
_version_ 1724296244404158464