Macromodel of Precise Signal-Phase Meter
This paper presents a precise macromodel of a signal-phase meter, which allows continuous phase measurement during simulation. It has been developed as a support tool during the design process of a signal-conditioning circuit for incremental position encoders. The development of a signal conditionin...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2012-01-01
|
Series: | Modelling and Simulation in Engineering |
Online Access: | http://dx.doi.org/10.1155/2012/856497 |
id |
doaj-a0b24bb2b09540a1baab523ca5e3893a |
---|---|
record_format |
Article |
spelling |
doaj-a0b24bb2b09540a1baab523ca5e3893a2020-11-24T21:30:43ZengHindawi LimitedModelling and Simulation in Engineering1687-55911687-56052012-01-01201210.1155/2012/856497856497Macromodel of Precise Signal-Phase MeterMatej Šalamon0Bojan Jarc1Faculty of Electrical Engineering and Computer Science, University of Maribor, SI-2000 Maribor, SloveniaFaculty of Electrical Engineering and Computer Science, University of Maribor, SI-2000 Maribor, SloveniaThis paper presents a precise macromodel of a signal-phase meter, which allows continuous phase measurement during simulation. It has been developed as a support tool during the design process of a signal-conditioning circuit for incremental position encoders. The development of a signal conditioning circuit requires precise measurements of small signal phases, amplitudes and offsets using the analog/digital circuit simulator. The phase measurement cannot be performed directly with a simulator, therefore an appropriate macro-model is needed for a circuit simulator. The structure of the signal-phase meter is based on the conventional signal-phase measuring method and is intended for the measuring of a cosine-signal phase with a known frequency. It recommends that the time variations of an input signal’s parameters (amplitude, phase, frequency, and offset voltage) are slow and small as possible. Rapid change of a signal’s parameters decreases the simulation result’s accuracy. A macro-model’s precision mainly depends on the chosen parameters for the macro-model and for the simulation. We show that with the proposed meter’s model, the phase angle can be measured with an accuracy of more than ±0,02%.http://dx.doi.org/10.1155/2012/856497 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Matej Šalamon Bojan Jarc |
spellingShingle |
Matej Šalamon Bojan Jarc Macromodel of Precise Signal-Phase Meter Modelling and Simulation in Engineering |
author_facet |
Matej Šalamon Bojan Jarc |
author_sort |
Matej Šalamon |
title |
Macromodel of Precise Signal-Phase Meter |
title_short |
Macromodel of Precise Signal-Phase Meter |
title_full |
Macromodel of Precise Signal-Phase Meter |
title_fullStr |
Macromodel of Precise Signal-Phase Meter |
title_full_unstemmed |
Macromodel of Precise Signal-Phase Meter |
title_sort |
macromodel of precise signal-phase meter |
publisher |
Hindawi Limited |
series |
Modelling and Simulation in Engineering |
issn |
1687-5591 1687-5605 |
publishDate |
2012-01-01 |
description |
This paper presents a precise macromodel of a signal-phase meter, which allows continuous phase measurement during simulation. It has been developed as a support tool during the design process of a signal-conditioning circuit for incremental position encoders. The development of a signal conditioning circuit requires precise measurements of small signal phases, amplitudes and offsets using the analog/digital circuit simulator. The phase measurement cannot be performed directly with a simulator, therefore an appropriate macro-model is needed for a circuit simulator. The structure of the signal-phase meter is based on the conventional signal-phase measuring method and is intended for the measuring of a cosine-signal phase with a known frequency. It recommends that the time variations of an input signal’s parameters (amplitude, phase, frequency, and offset voltage) are slow and small as possible. Rapid change of a signal’s parameters decreases the simulation result’s accuracy. A macro-model’s precision mainly depends on the chosen parameters for the macro-model and for the simulation. We show that with the proposed meter’s model, the phase angle can be measured with an accuracy of more than ±0,02%. |
url |
http://dx.doi.org/10.1155/2012/856497 |
work_keys_str_mv |
AT matejsalamon macromodelofprecisesignalphasemeter AT bojanjarc macromodelofprecisesignalphasemeter |
_version_ |
1725961960851243008 |