Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices
The extracortical clamp device (ECD) is a tool used in external fixation which unlike the K-wires and half-pins don’t perforate cortical bone. The use of ECD is prospective for the treatment of periprosthetic femoral fractures and in the lengthening over nail and bone transport over nail. The data o...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Vreden Russian Research Institute of Traumatology and Orthopedics
2016-09-01
|
Series: | Travmatologiâ i Ortopediâ Rossii |
Subjects: | |
Online Access: | https://journal.rniito.org/jour/article/view/115 |
id |
doaj-a032ba3aac034d63b30bb237275b507e |
---|---|
record_format |
Article |
spelling |
doaj-a032ba3aac034d63b30bb237275b507e2021-07-29T08:01:15ZrusVreden Russian Research Institute of Traumatology and OrthopedicsTravmatologiâ i Ortopediâ Rossii2311-29052542-09332016-09-0101586510.21823/2311-2905-2015-0-1-60-65112Tne stiffness of first-order and second-order modules assembled with extracortical clamp devicesF. K. Sabirov0L. N. Solomin1Vreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and Orthopedics; St. Petersburg State UniversityThe extracortical clamp device (ECD) is a tool used in external fixation which unlike the K-wires and half-pins don’t perforate cortical bone. The use of ECD is prospective for the treatment of periprosthetic femoral fractures and in the lengthening over nail and bone transport over nail. The data on the bench tests of the osteosynthesis rigidity by the external fixation first-order and second-order modules on the base of extracortical clamp devices are observed in the article. Materials and methods. The authors made 240 bench tests using torsional-vibration machine, Indicators measuring linear displacements with a scale of 0.01 mm, bone simulators («Sawbones»), calibrated load, Ilizarov’s apparatus и extracortical fixators. The statistical analysis was performed with use software «STATISTICA» (ver. 6.0). The data obtained are presented in graphs «Box and Whisker Plot». Results. Among the investigated variants of first-order modules the better results of osteosynthesis rigidity were found in the module based on two ECD inserted at angle 60 degrees to each other and at distance of 10 cm from each other. Among the investigated second-order modules, better results of osteosynthesis rigidity were found in the module based on two ECD inserted at an angle 60 degrees to each other at distance of 10 cm from each other. Conclusion. Thus the tested modules can be used in practice in assemblies of external fixation devices in periprosthetic fractures, lengthening and bone transport over the nail.https://journal.rniito.org/jour/article/view/115экстракортикальный фиксаторжесткость остеосинтезавнешняя фиксациястендовые исследованияextracortical clamp deviceosteosynthesis stiffnessexternal fixationbench tests |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
F. K. Sabirov L. N. Solomin |
spellingShingle |
F. K. Sabirov L. N. Solomin Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices Travmatologiâ i Ortopediâ Rossii экстракортикальный фиксатор жесткость остеосинтеза внешняя фиксация стендовые исследования extracortical clamp device osteosynthesis stiffness external fixation bench tests |
author_facet |
F. K. Sabirov L. N. Solomin |
author_sort |
F. K. Sabirov |
title |
Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
title_short |
Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
title_full |
Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
title_fullStr |
Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
title_full_unstemmed |
Tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
title_sort |
tne stiffness of first-order and second-order modules assembled with extracortical clamp devices |
publisher |
Vreden Russian Research Institute of Traumatology and Orthopedics |
series |
Travmatologiâ i Ortopediâ Rossii |
issn |
2311-2905 2542-0933 |
publishDate |
2016-09-01 |
description |
The extracortical clamp device (ECD) is a tool used in external fixation which unlike the K-wires and half-pins don’t perforate cortical bone. The use of ECD is prospective for the treatment of periprosthetic femoral fractures and in the lengthening over nail and bone transport over nail. The data on the bench tests of the osteosynthesis rigidity by the external fixation first-order and second-order modules on the base of extracortical clamp devices are observed in the article. Materials and methods. The authors made 240 bench tests using torsional-vibration machine, Indicators measuring linear displacements with a scale of 0.01 mm, bone simulators («Sawbones»), calibrated load, Ilizarov’s apparatus и extracortical fixators. The statistical analysis was performed with use software «STATISTICA» (ver. 6.0). The data obtained are presented in graphs «Box and Whisker Plot». Results. Among the investigated variants of first-order modules the better results of osteosynthesis rigidity were found in the module based on two ECD inserted at angle 60 degrees to each other and at distance of 10 cm from each other. Among the investigated second-order modules, better results of osteosynthesis rigidity were found in the module based on two ECD inserted at an angle 60 degrees to each other at distance of 10 cm from each other. Conclusion. Thus the tested modules can be used in practice in assemblies of external fixation devices in periprosthetic fractures, lengthening and bone transport over the nail. |
topic |
экстракортикальный фиксатор жесткость остеосинтеза внешняя фиксация стендовые исследования extracortical clamp device osteosynthesis stiffness external fixation bench tests |
url |
https://journal.rniito.org/jour/article/view/115 |
work_keys_str_mv |
AT fksabirov tnestiffnessoffirstorderandsecondordermodulesassembledwithextracorticalclampdevices AT lnsolomin tnestiffnessoffirstorderandsecondordermodulesassembledwithextracorticalclampdevices |
_version_ |
1721259079326760960 |