Experimental study of the load-deformation behaviour of the precast post-tensioned continuous girder for straddle monorail: Full-scale load test under service and ultimate loading conditions

This study presented the results of an experimental program conducted on a newly proposed Full-scale Precast Post-tensioned Continuous (FPPC) girder for straddle monorail. The investigated FPPC girder represents the actual size, design and construction details for a newly designed monorail transit s...