Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer

Aims. Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods...

Full description

Bibliographic Details
Main Authors: Yadong Feng, Qian Yu, Ming Li, Wei Xu, Ye Zhu, Yang Liu, Ruihua Shi
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Gastroenterology Research and Practice
Online Access:http://dx.doi.org/10.1155/2020/6810164
id doaj-9f7fb877914147e5999e8b3045303309
record_format Article
spelling doaj-9f7fb877914147e5999e8b30453033092020-11-25T01:19:54ZengHindawi LimitedGastroenterology Research and Practice1687-61211687-630X2020-01-01202010.1155/2020/68101646810164Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal CancerYadong Feng0Qian Yu1Ming Li2Wei Xu3Ye Zhu4Yang Liu5Ruihua Shi6Department of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing, 210009, ChinaAims. Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods. A total of 36 patients with an acute colonic obstruction caused by CRC underwent endoscopic SEMS insertion using a colonoscope without fluoroscopic guidance, followed by analyses of the technical and clinical success and short-term complications. Results. Total technical success rate and clinical success rate were 91.7% and 86.1%, respectively. The mean procedure time was 21.2±10.3 minutes. There was no stent dislodgement. One case of hematochezia and two cases of tenesmus occurred in patients with left-sided complete obstructions. No other short-term complications occurred. Procedure time, technical success, and clinical success rate were 16.3±9.4 minutes, 93.1%, and 89.6% for left-sided obstructions, respectively, and were 26.8±10.7 minutes, 85.7%, and 71.4% for right-sided obstructions, respectively. For complete obstructions, procedure time, technical success, and clinical success rate were 22.5±8.9 minutes, 90%, and 83.3%, respectively. In the incomplete cases, procedure time, technical success, and clinical success were 13.5±6.7 minutes, 100%, and 100%, respectively. Technical success, clinical success, and short-term complications were not differed between lesion locations and degrees. Conclusions. This simple technique is feasible and safe for palliation of acute colonic obstruction caused by CRC.http://dx.doi.org/10.1155/2020/6810164
collection DOAJ
language English
format Article
sources DOAJ
author Yadong Feng
Qian Yu
Ming Li
Wei Xu
Ye Zhu
Yang Liu
Ruihua Shi
spellingShingle Yadong Feng
Qian Yu
Ming Li
Wei Xu
Ye Zhu
Yang Liu
Ruihua Shi
Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
Gastroenterology Research and Practice
author_facet Yadong Feng
Qian Yu
Ming Li
Wei Xu
Ye Zhu
Yang Liu
Ruihua Shi
author_sort Yadong Feng
title Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
title_short Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
title_full Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
title_fullStr Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
title_full_unstemmed Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
title_sort endoscopic self-expandable metallic stent insertion without fluoroscopic guidance is feasible and safe for acute colonic obstruction caused by colorectal cancer
publisher Hindawi Limited
series Gastroenterology Research and Practice
issn 1687-6121
1687-630X
publishDate 2020-01-01
description Aims. Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods. A total of 36 patients with an acute colonic obstruction caused by CRC underwent endoscopic SEMS insertion using a colonoscope without fluoroscopic guidance, followed by analyses of the technical and clinical success and short-term complications. Results. Total technical success rate and clinical success rate were 91.7% and 86.1%, respectively. The mean procedure time was 21.2±10.3 minutes. There was no stent dislodgement. One case of hematochezia and two cases of tenesmus occurred in patients with left-sided complete obstructions. No other short-term complications occurred. Procedure time, technical success, and clinical success rate were 16.3±9.4 minutes, 93.1%, and 89.6% for left-sided obstructions, respectively, and were 26.8±10.7 minutes, 85.7%, and 71.4% for right-sided obstructions, respectively. For complete obstructions, procedure time, technical success, and clinical success rate were 22.5±8.9 minutes, 90%, and 83.3%, respectively. In the incomplete cases, procedure time, technical success, and clinical success were 13.5±6.7 minutes, 100%, and 100%, respectively. Technical success, clinical success, and short-term complications were not differed between lesion locations and degrees. Conclusions. This simple technique is feasible and safe for palliation of acute colonic obstruction caused by CRC.
url http://dx.doi.org/10.1155/2020/6810164
work_keys_str_mv AT yadongfeng endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT qianyu endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT mingli endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT weixu endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT yezhu endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT yangliu endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
AT ruihuashi endoscopicselfexpandablemetallicstentinsertionwithoutfluoroscopicguidanceisfeasibleandsafeforacutecolonicobstructioncausedbycolorectalcancer
_version_ 1715796869637996544