Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction

We investigate the effect of renal artery angle variation and Reynolds number on the probability of formation of atherosclerosis-prone regions at the abdominal aorta-renal artery junction. The rheologically accurate shear-thinning Yeleswarapu model for blood is used to simulate flow in a 3-Dimension...

Full description

Bibliographic Details
Main Authors: Mohammed Ameenuddin, Mohan Anand
Format: Article
Language:English
Published: Atlantis Press 2017-12-01
Series:Artery Research
Subjects:
Online Access:https://www.atlantis-press.com/article/125924953/view
id doaj-9f556864b3c54e8b9cbfad8754e8ff4b
record_format Article
spelling doaj-9f556864b3c54e8b9cbfad8754e8ff4b2020-11-25T02:22:44ZengAtlantis PressArtery Research 1876-44012017-12-012110.1016/j.artres.2017.11.007Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junctionMohammed AmeenuddinMohan AnandWe investigate the effect of renal artery angle variation and Reynolds number on the probability of formation of atherosclerosis-prone regions at the abdominal aorta-renal artery junction. The rheologically accurate shear-thinning Yeleswarapu model for blood is used to simulate flow in a 3-Dimensional T-junction whose dimensions are those of the human abdominal aorta-renal artery junction. The recirculation length and wall shear stresses are evaluated at the junction for steady, laminar flow using ANSYS FLUENT v14.5. The recirculation length and wall shear stresses are calculated for Reynolds number of 500–1500, and the angle of renal artery (with the horizontal axis) of −20° to +20°. Computational fluid dynamics analysis for the flow conditions used in present study show that the flow recirculation and low wall shear stress regions overlap at the top surface of renal artery downstream of the entrance and at the curved surface of abdominal aorta downstream of the junction, making these regions susceptible to atherosclerosis. Further investigations show that positive angles of renal artery have larger area of recirculation and larger low wall shear stress regions. The recirculation length increases with Reynolds number, and it is maximum when θ = +20°, and minimum when θ = −20°.https://www.atlantis-press.com/article/125924953/viewAbdominal aortaAtherosclerosisRecirculationRenal arteryYeleswarapu model
collection DOAJ
language English
format Article
sources DOAJ
author Mohammed Ameenuddin
Mohan Anand
spellingShingle Mohammed Ameenuddin
Mohan Anand
Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
Artery Research
Abdominal aorta
Atherosclerosis
Recirculation
Renal artery
Yeleswarapu model
author_facet Mohammed Ameenuddin
Mohan Anand
author_sort Mohammed Ameenuddin
title Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
title_short Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
title_full Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
title_fullStr Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
title_full_unstemmed Effect of angulation and Reynolds number on recirculation at the abdominal aorta-renal artery junction
title_sort effect of angulation and reynolds number on recirculation at the abdominal aorta-renal artery junction
publisher Atlantis Press
series Artery Research
issn 1876-4401
publishDate 2017-12-01
description We investigate the effect of renal artery angle variation and Reynolds number on the probability of formation of atherosclerosis-prone regions at the abdominal aorta-renal artery junction. The rheologically accurate shear-thinning Yeleswarapu model for blood is used to simulate flow in a 3-Dimensional T-junction whose dimensions are those of the human abdominal aorta-renal artery junction. The recirculation length and wall shear stresses are evaluated at the junction for steady, laminar flow using ANSYS FLUENT v14.5. The recirculation length and wall shear stresses are calculated for Reynolds number of 500–1500, and the angle of renal artery (with the horizontal axis) of −20° to +20°. Computational fluid dynamics analysis for the flow conditions used in present study show that the flow recirculation and low wall shear stress regions overlap at the top surface of renal artery downstream of the entrance and at the curved surface of abdominal aorta downstream of the junction, making these regions susceptible to atherosclerosis. Further investigations show that positive angles of renal artery have larger area of recirculation and larger low wall shear stress regions. The recirculation length increases with Reynolds number, and it is maximum when θ = +20°, and minimum when θ = −20°.
topic Abdominal aorta
Atherosclerosis
Recirculation
Renal artery
Yeleswarapu model
url https://www.atlantis-press.com/article/125924953/view
work_keys_str_mv AT mohammedameenuddin effectofangulationandreynoldsnumberonrecirculationattheabdominalaortarenalarteryjunction
AT mohananand effectofangulationandreynoldsnumberonrecirculationattheabdominalaortarenalarteryjunction
_version_ 1724862030466252800