Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis

Abstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The...

Full description

Bibliographic Details
Main Authors: Mustafa S. Mahmood, Shatha S. Al-Ameer
Format: Article
Language:English
Published: College of Dentistry/ University of Baghdad 2017-03-01
Series:Journal of Baghdad College of Dentistry
Online Access:https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/1738
id doaj-9ed401f313914168a63babaed3b6b000
record_format Article
spelling doaj-9ed401f313914168a63babaed3b6b0002021-09-02T21:58:16ZengCollege of Dentistry/ University of BaghdadJournal of Baghdad College of Dentistry2311-52702017-03-0129110.12816/0038618Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric AnalysisMustafa S. MahmoodShatha S. Al-AmeerAbstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The surface of disc samples after coating was checked by optical microscopy, X-ray diffraction examination and measurement of coating thickness. Ten male white French rabbits were prepared for implantation. Forty screws were implanted in the femur bone, two implant screws in each femur bone. The first screw is coated with calcium carbonate and compared with the second uncoated screw. Rabbits are divided into two groups according to the healing periods 2 and 6 weeks. By torque removal, the osseointegration is measured. Single screw from each group was used for histological and Histomorphometric analysis. Results: There was significant increased mean torque removal for screws coated with calcium carbonate compared with uncoated screws. Histological examination showed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis showed an increase in new bone formation percent (NBFP). Conclusion: Coating the surface of the CP Ti implant with calcium carbonate via electrophoretic deposition method had great effect in increasing the osseointegration than uncoated surface. https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/1738
collection DOAJ
language English
format Article
sources DOAJ
author Mustafa S. Mahmood
Shatha S. Al-Ameer
spellingShingle Mustafa S. Mahmood
Shatha S. Al-Ameer
Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
Journal of Baghdad College of Dentistry
author_facet Mustafa S. Mahmood
Shatha S. Al-Ameer
author_sort Mustafa S. Mahmood
title Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
title_short Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
title_full Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
title_fullStr Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
title_full_unstemmed Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
title_sort assessment of calcium carbonate coating on osseointegration of commercially pure titanium implant by torque removal test and histomorphometric analysis
publisher College of Dentistry/ University of Baghdad
series Journal of Baghdad College of Dentistry
issn 2311-5270
publishDate 2017-03-01
description Abstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The surface of disc samples after coating was checked by optical microscopy, X-ray diffraction examination and measurement of coating thickness. Ten male white French rabbits were prepared for implantation. Forty screws were implanted in the femur bone, two implant screws in each femur bone. The first screw is coated with calcium carbonate and compared with the second uncoated screw. Rabbits are divided into two groups according to the healing periods 2 and 6 weeks. By torque removal, the osseointegration is measured. Single screw from each group was used for histological and Histomorphometric analysis. Results: There was significant increased mean torque removal for screws coated with calcium carbonate compared with uncoated screws. Histological examination showed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis showed an increase in new bone formation percent (NBFP). Conclusion: Coating the surface of the CP Ti implant with calcium carbonate via electrophoretic deposition method had great effect in increasing the osseointegration than uncoated surface.
url https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/1738
work_keys_str_mv AT mustafasmahmood assessmentofcalciumcarbonatecoatingonosseointegrationofcommerciallypuretitaniumimplantbytorqueremovaltestandhistomorphometricanalysis
AT shathasalameer assessmentofcalciumcarbonatecoatingonosseointegrationofcommerciallypuretitaniumimplantbytorqueremovaltestandhistomorphometricanalysis
_version_ 1717819072876380160