Heating storage performance of a water tank–combined phase change material:An experimental case study

Water tank is a commonly used unit which has been frequently applied for thermal energy storage units. In order to enhance the thermal performance of the water tank, the phase change material is utilized by embedding paraffin into water tank. But the key question is whether a competitive charging co...

Full description

Bibliographic Details
Main Authors: Ling Xie, Yifei Lv, Jun Lu, Yongcai Li, Shuli Liu, Qiusheng Zou, Xi Wang
Format: Article
Language:English
Published: SAGE Publishing 2017-10-01
Series:Advances in Mechanical Engineering
Online Access:https://doi.org/10.1177/1687814017724071
id doaj-9e6a83a00d964c2b8a3120682c62c316
record_format Article
spelling doaj-9e6a83a00d964c2b8a3120682c62c3162020-11-25T01:25:46ZengSAGE PublishingAdvances in Mechanical Engineering1687-81402017-10-01910.1177/1687814017724071Heating storage performance of a water tank–combined phase change material:An experimental case studyLing Xie0Yifei Lv1Jun Lu2Yongcai Li3Shuli Liu4Qiusheng Zou5Xi Wang6Key Laboratory of the Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing, ChinaKey Laboratory of the Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing, ChinaKey Laboratory of the Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing, ChinaKey Laboratory of the Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing, ChinaSchool of Energy, Construction and Environment, Coventry University, Coventry, UKSichuan Provincial Architectural Design and Research Institute, Chengdu, ChinaSichuan Provincial Architectural Design and Research Institute, Chengdu, ChinaWater tank is a commonly used unit which has been frequently applied for thermal energy storage units. In order to enhance the thermal performance of the water tank, the phase change material is utilized by embedding paraffin into water tank. But the key question is whether a competitive charging could be achieved. Therefore, an experimental system has been constructed. In this article, two key indices, the energy storage capacity and the energy storage intensity, are investigated. The performances of the phase change material–thermal energy storage tank during the heat charging processes are investigated experimentally, and a series of experiments are carried out under different heat transfer fluid flow rates and distance between phase change material plates. The temperature evolutions of the phase change material plates and heat transfer fluid are obtained during the experiments. The thermal performance of the phase change material–thermal energy storage tank was observed to be more effective than the conventional sensible thermal energy storage tank. It is found that water flow rate of 1.3 m 3 /h is taken as the optimal working condition, and the 3-cm plate distance is considered as the optimal design.https://doi.org/10.1177/1687814017724071
collection DOAJ
language English
format Article
sources DOAJ
author Ling Xie
Yifei Lv
Jun Lu
Yongcai Li
Shuli Liu
Qiusheng Zou
Xi Wang
spellingShingle Ling Xie
Yifei Lv
Jun Lu
Yongcai Li
Shuli Liu
Qiusheng Zou
Xi Wang
Heating storage performance of a water tank–combined phase change material:An experimental case study
Advances in Mechanical Engineering
author_facet Ling Xie
Yifei Lv
Jun Lu
Yongcai Li
Shuli Liu
Qiusheng Zou
Xi Wang
author_sort Ling Xie
title Heating storage performance of a water tank–combined phase change material:An experimental case study
title_short Heating storage performance of a water tank–combined phase change material:An experimental case study
title_full Heating storage performance of a water tank–combined phase change material:An experimental case study
title_fullStr Heating storage performance of a water tank–combined phase change material:An experimental case study
title_full_unstemmed Heating storage performance of a water tank–combined phase change material:An experimental case study
title_sort heating storage performance of a water tank–combined phase change material:an experimental case study
publisher SAGE Publishing
series Advances in Mechanical Engineering
issn 1687-8140
publishDate 2017-10-01
description Water tank is a commonly used unit which has been frequently applied for thermal energy storage units. In order to enhance the thermal performance of the water tank, the phase change material is utilized by embedding paraffin into water tank. But the key question is whether a competitive charging could be achieved. Therefore, an experimental system has been constructed. In this article, two key indices, the energy storage capacity and the energy storage intensity, are investigated. The performances of the phase change material–thermal energy storage tank during the heat charging processes are investigated experimentally, and a series of experiments are carried out under different heat transfer fluid flow rates and distance between phase change material plates. The temperature evolutions of the phase change material plates and heat transfer fluid are obtained during the experiments. The thermal performance of the phase change material–thermal energy storage tank was observed to be more effective than the conventional sensible thermal energy storage tank. It is found that water flow rate of 1.3 m 3 /h is taken as the optimal working condition, and the 3-cm plate distance is considered as the optimal design.
url https://doi.org/10.1177/1687814017724071
work_keys_str_mv AT lingxie heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT yifeilv heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT junlu heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT yongcaili heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT shuliliu heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT qiushengzou heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
AT xiwang heatingstorageperformanceofawatertankcombinedphasechangematerialanexperimentalcasestudy
_version_ 1725111959028760576