Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method

Dispersive liquid−liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent...

Full description

Bibliographic Details
Main Authors: Marta Hryniewicka, Barbara Starczewska, Agnieszka Gołębiewska
Format: Article
Language:English
Published: MDPI AG 2019-07-01
Series:Water
Subjects:
Online Access:https://www.mdpi.com/2073-4441/11/8/1581
id doaj-9e029ea4dc514c46a45e805fdfdb342a
record_format Article
spelling doaj-9e029ea4dc514c46a45e805fdfdb342a2020-11-24T21:24:16ZengMDPI AGWater2073-44412019-07-01118158110.3390/w11081581w11081581Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV MethodMarta Hryniewicka0Barbara Starczewska1Agnieszka Gołębiewska2Institute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandInstitute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandInstitute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandDispersive liquid&#8722;liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent and dispersive solvent, ionic strength, pH of sample, and centrifugation time were investigated. Moreover, the influence of foreign substances on a studied process was tested. The calibration curves were recorded. The linearity ranges for BUD and SULF were 0.022&#8722;8.611 &#181;g mL<sup>&#8722;1</sup> and 0.020&#8722;7.968 &#181;g mL<sup>&#8722;1</sup> with the limit of detection (LOD) 0.011 &#181;g mL<sup>&#8722;1</sup> and 0.012 &#181;g mL<sup>&#8722;1</sup>, respectively. The enrichment factors (EF) for two analytes were high: for BUD it was 145.7 and for SULF, 119.5. The elaborated procedure was applied for HPLC-UV determination of these analytes in water and wastewater samples.https://www.mdpi.com/2073-4441/11/8/1581budesonidesulfasalazine1-undecanolDLLME-SFOHPLC-UV
collection DOAJ
language English
format Article
sources DOAJ
author Marta Hryniewicka
Barbara Starczewska
Agnieszka Gołębiewska
spellingShingle Marta Hryniewicka
Barbara Starczewska
Agnieszka Gołębiewska
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
Water
budesonide
sulfasalazine
1-undecanol
DLLME-SFO
HPLC-UV
author_facet Marta Hryniewicka
Barbara Starczewska
Agnieszka Gołębiewska
author_sort Marta Hryniewicka
title Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
title_short Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
title_full Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
title_fullStr Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
title_full_unstemmed Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
title_sort determination of budesonide and sulfasalazine in water and wastewater samples using dllme-sfo-hplc-uv method
publisher MDPI AG
series Water
issn 2073-4441
publishDate 2019-07-01
description Dispersive liquid&#8722;liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent and dispersive solvent, ionic strength, pH of sample, and centrifugation time were investigated. Moreover, the influence of foreign substances on a studied process was tested. The calibration curves were recorded. The linearity ranges for BUD and SULF were 0.022&#8722;8.611 &#181;g mL<sup>&#8722;1</sup> and 0.020&#8722;7.968 &#181;g mL<sup>&#8722;1</sup> with the limit of detection (LOD) 0.011 &#181;g mL<sup>&#8722;1</sup> and 0.012 &#181;g mL<sup>&#8722;1</sup>, respectively. The enrichment factors (EF) for two analytes were high: for BUD it was 145.7 and for SULF, 119.5. The elaborated procedure was applied for HPLC-UV determination of these analytes in water and wastewater samples.
topic budesonide
sulfasalazine
1-undecanol
DLLME-SFO
HPLC-UV
url https://www.mdpi.com/2073-4441/11/8/1581
work_keys_str_mv AT martahryniewicka determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod
AT barbarastarczewska determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod
AT agnieszkagołebiewska determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod
_version_ 1725989314410577920