Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method
Dispersive liquid−liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-07-01
|
Series: | Water |
Subjects: | |
Online Access: | https://www.mdpi.com/2073-4441/11/8/1581 |
id |
doaj-9e029ea4dc514c46a45e805fdfdb342a |
---|---|
record_format |
Article |
spelling |
doaj-9e029ea4dc514c46a45e805fdfdb342a2020-11-24T21:24:16ZengMDPI AGWater2073-44412019-07-01118158110.3390/w11081581w11081581Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV MethodMarta Hryniewicka0Barbara Starczewska1Agnieszka Gołębiewska2Institute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandInstitute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandInstitute of Chemistry, University of Białystok, ul. Ciołkowskiego 1K, 15-245 Białystok, PolandDispersive liquid−liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent and dispersive solvent, ionic strength, pH of sample, and centrifugation time were investigated. Moreover, the influence of foreign substances on a studied process was tested. The calibration curves were recorded. The linearity ranges for BUD and SULF were 0.022−8.611 µg mL<sup>−1</sup> and 0.020−7.968 µg mL<sup>−1</sup> with the limit of detection (LOD) 0.011 µg mL<sup>−1</sup> and 0.012 µg mL<sup>−1</sup>, respectively. The enrichment factors (EF) for two analytes were high: for BUD it was 145.7 and for SULF, 119.5. The elaborated procedure was applied for HPLC-UV determination of these analytes in water and wastewater samples.https://www.mdpi.com/2073-4441/11/8/1581budesonidesulfasalazine1-undecanolDLLME-SFOHPLC-UV |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marta Hryniewicka Barbara Starczewska Agnieszka Gołębiewska |
spellingShingle |
Marta Hryniewicka Barbara Starczewska Agnieszka Gołębiewska Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method Water budesonide sulfasalazine 1-undecanol DLLME-SFO HPLC-UV |
author_facet |
Marta Hryniewicka Barbara Starczewska Agnieszka Gołębiewska |
author_sort |
Marta Hryniewicka |
title |
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method |
title_short |
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method |
title_full |
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method |
title_fullStr |
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method |
title_full_unstemmed |
Determination of Budesonide and Sulfasalazine in Water and Wastewater Samples Using DLLME-SFO-HPLC-UV Method |
title_sort |
determination of budesonide and sulfasalazine in water and wastewater samples using dllme-sfo-hplc-uv method |
publisher |
MDPI AG |
series |
Water |
issn |
2073-4441 |
publishDate |
2019-07-01 |
description |
Dispersive liquid−liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) was applied to isolate budesonide (BUD) and sulfasalazine (SULF) from aqueous samples. The effects of different parameters on the efficiency on the extraction such as type of extrahent and dispersive solvent, ionic strength, pH of sample, and centrifugation time were investigated. Moreover, the influence of foreign substances on a studied process was tested. The calibration curves were recorded. The linearity ranges for BUD and SULF were 0.022−8.611 µg mL<sup>−1</sup> and 0.020−7.968 µg mL<sup>−1</sup> with the limit of detection (LOD) 0.011 µg mL<sup>−1</sup> and 0.012 µg mL<sup>−1</sup>, respectively. The enrichment factors (EF) for two analytes were high: for BUD it was 145.7 and for SULF, 119.5. The elaborated procedure was applied for HPLC-UV determination of these analytes in water and wastewater samples. |
topic |
budesonide sulfasalazine 1-undecanol DLLME-SFO HPLC-UV |
url |
https://www.mdpi.com/2073-4441/11/8/1581 |
work_keys_str_mv |
AT martahryniewicka determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod AT barbarastarczewska determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod AT agnieszkagołebiewska determinationofbudesonideandsulfasalazineinwaterandwastewatersamplesusingdllmesfohplcuvmethod |
_version_ |
1725989314410577920 |