How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?
PURPOSE:To investigate the dose variation between follow-up CT examinations, when a patient is examined several times on the same scanner with the identical scan protocol which comprised automated exposure control. MATERIAL AND METHODS:This retrospective study was approved by the local ethics commit...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2016-01-01
|
Series: | PLoS ONE |
Online Access: | http://europepmc.org/articles/PMC4822887?pdf=render |
id |
doaj-9d8e615aae7045c7b43005d7fa46df0e |
---|---|
record_format |
Article |
spelling |
doaj-9d8e615aae7045c7b43005d7fa46df0e2020-11-25T02:33:50ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01114e015296110.1371/journal.pone.0152961How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?Saravanabavaan SuntharalingamFranz Ferdinand SteckerNika GuberinaAdrian RingelsteinThomas SchlosserJens Matthias TheysohnMichael ForstingKai NassensteinPURPOSE:To investigate the dose variation between follow-up CT examinations, when a patient is examined several times on the same scanner with the identical scan protocol which comprised automated exposure control. MATERIAL AND METHODS:This retrospective study was approved by the local ethics committee. The volume computed tomography dose index (CTDIvol) and the dose-length-product (DLP) were recorded for 60 cancer patients (29 male, 31 female, mean age 60.1 years), who received 3 follow-up CT examinations each composed of a non-enhanced scan of the liver (LI-CT) and a contrast-enhanced scan of chest (CH-CT) and abdomen (AB-CT). Each examination was performed on the same scanner (Siemens Definition FLASH) equipped with automated exposure control (CARE Dose 4D and CARE KV) using the identical scan protocol. RESULTS:The median percentage difference in DLP between follow-up examinations was 9.6% for CH-CT, 10.3% for LI-CT, and 10.1% for AB-CT; the median percentage difference in CTDIvol 8.3% for CH-CT, 7.4% for LI-CT and 7.7% for AB-CT (p<0.0001 for all values). The maximum difference in DLP between follow-up examinations was 67.5% for CH-CT, 50.8% for LI-CT and 74.3% for AB-CT; the maximum difference in CTDIvol 62.9% for CH-CT, 47.2% for LI-CT, and 49% for AB-CT. CONCLUSION:A significant variance in the radiation dose occurs between follow-up CT examinations when the same CT scanner and the identical imaging protocol are used in combination with automated exposure control.http://europepmc.org/articles/PMC4822887?pdf=render |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Saravanabavaan Suntharalingam Franz Ferdinand Stecker Nika Guberina Adrian Ringelstein Thomas Schlosser Jens Matthias Theysohn Michael Forsting Kai Nassenstein |
spellingShingle |
Saravanabavaan Suntharalingam Franz Ferdinand Stecker Nika Guberina Adrian Ringelstein Thomas Schlosser Jens Matthias Theysohn Michael Forsting Kai Nassenstein How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? PLoS ONE |
author_facet |
Saravanabavaan Suntharalingam Franz Ferdinand Stecker Nika Guberina Adrian Ringelstein Thomas Schlosser Jens Matthias Theysohn Michael Forsting Kai Nassenstein |
author_sort |
Saravanabavaan Suntharalingam |
title |
How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? |
title_short |
How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? |
title_full |
How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? |
title_fullStr |
How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? |
title_full_unstemmed |
How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol? |
title_sort |
how much is the dose varying between follow-up ct-examinations performed on the same scanner with the same imaging protocol? |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2016-01-01 |
description |
PURPOSE:To investigate the dose variation between follow-up CT examinations, when a patient is examined several times on the same scanner with the identical scan protocol which comprised automated exposure control. MATERIAL AND METHODS:This retrospective study was approved by the local ethics committee. The volume computed tomography dose index (CTDIvol) and the dose-length-product (DLP) were recorded for 60 cancer patients (29 male, 31 female, mean age 60.1 years), who received 3 follow-up CT examinations each composed of a non-enhanced scan of the liver (LI-CT) and a contrast-enhanced scan of chest (CH-CT) and abdomen (AB-CT). Each examination was performed on the same scanner (Siemens Definition FLASH) equipped with automated exposure control (CARE Dose 4D and CARE KV) using the identical scan protocol. RESULTS:The median percentage difference in DLP between follow-up examinations was 9.6% for CH-CT, 10.3% for LI-CT, and 10.1% for AB-CT; the median percentage difference in CTDIvol 8.3% for CH-CT, 7.4% for LI-CT and 7.7% for AB-CT (p<0.0001 for all values). The maximum difference in DLP between follow-up examinations was 67.5% for CH-CT, 50.8% for LI-CT and 74.3% for AB-CT; the maximum difference in CTDIvol 62.9% for CH-CT, 47.2% for LI-CT, and 49% for AB-CT. CONCLUSION:A significant variance in the radiation dose occurs between follow-up CT examinations when the same CT scanner and the identical imaging protocol are used in combination with automated exposure control. |
url |
http://europepmc.org/articles/PMC4822887?pdf=render |
work_keys_str_mv |
AT saravanabavaansuntharalingam howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT franzferdinandstecker howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT nikaguberina howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT adrianringelstein howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT thomasschlosser howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT jensmatthiastheysohn howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT michaelforsting howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol AT kainassenstein howmuchisthedosevaryingbetweenfollowupctexaminationsperformedonthesamescannerwiththesameimagingprotocol |
_version_ |
1724812170605101056 |