THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE

A method for spectrophotometric determination of the total IO3− and IO4—ions was proposed. The method is based on the oxidation of N,N-diethylaniline in an excess of potassium bromide in the presence of sulfuric acid medium and on the measurement of the bromination product absorbance at 226 nm. The...

Full description

Bibliographic Details
Main Author: O. S. Pogrebnyak
Format: Article
Language:English
Published: Odessa I. I. Mechnikov National University 2017-03-01
Series:Vìsnik Odesʹkogo Nacìonalʹnogo Unìversitetu: Hìmìâ
Subjects:
Online Access:http://heraldchem.onu.edu.ua/article/view/94720
id doaj-9d21209793084198bf92c5666ad3ffe0
record_format Article
spelling doaj-9d21209793084198bf92c5666ad3ffe02020-11-24T20:58:51ZengOdessa I. I. Mechnikov National University Vìsnik Odesʹkogo Nacìonalʹnogo Unìversitetu: Hìmìâ2304-09472414-59632017-03-01221(61)11912810.18524/2304-0947.2017.1(61).9472094720THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINEO. S. Pogrebnyak0Черкаський національний університет імені Богдана ХмельницькогоA method for spectrophotometric determination of the total IO3− and IO4—ions was proposed. The method is based on the oxidation of N,N-diethylaniline in an excess of potassium bromide in the presence of sulfuric acid medium and on the measurement of the bromination product absorbance at 226 nm. The influence of sulfuric acid concentration on the sensitivity of the measurement has been determined and the optimum conditions have been established. The detection limits (blank + 3s) for iodate, periodate and their total content equal to 0.73; 0.69 and 0.61 mg∙L−1, respectively. The linearity range of the calibration graph was found to be 1.0−11.0 mg∙L−1 (sr ≤ 0,10, n = 5). The possibility of separate determination of iodate and periodate based on selective extraction IO4− silica modified with a quaternary ammonium salt is proposed. The metrological characteristics of the procedure were checked by means of the “entered-found” method on the control samples. The relative error did not exceed 0.10 for iodate and periodate determination on the control samples, and the relative error was not higher than ± 8.00 %. The effect of foreign ions on the iodate and periodate determination at 2.0∙10−5 mol∙L–1 has been studied. The proposed procedure is simple and suitable for iodate and periodate determination in various objects.http://heraldchem.onu.edu.ua/article/view/94720йодатперйодатN,N-діетиланілінспектрофотометріячетвертина амонійна сіль
collection DOAJ
language English
format Article
sources DOAJ
author O. S. Pogrebnyak
spellingShingle O. S. Pogrebnyak
THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
Vìsnik Odesʹkogo Nacìonalʹnogo Unìversitetu: Hìmìâ
йодат
перйодат
N,N-діетиланілін
спектрофотометрія
четвертина амонійна сіль
author_facet O. S. Pogrebnyak
author_sort O. S. Pogrebnyak
title THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
title_short THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
title_full THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
title_fullStr THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
title_full_unstemmed THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE
title_sort spectrophotometric determination of nitrites with n,n-diethylaniline
publisher Odessa I. I. Mechnikov National University
series Vìsnik Odesʹkogo Nacìonalʹnogo Unìversitetu: Hìmìâ
issn 2304-0947
2414-5963
publishDate 2017-03-01
description A method for spectrophotometric determination of the total IO3− and IO4—ions was proposed. The method is based on the oxidation of N,N-diethylaniline in an excess of potassium bromide in the presence of sulfuric acid medium and on the measurement of the bromination product absorbance at 226 nm. The influence of sulfuric acid concentration on the sensitivity of the measurement has been determined and the optimum conditions have been established. The detection limits (blank + 3s) for iodate, periodate and their total content equal to 0.73; 0.69 and 0.61 mg∙L−1, respectively. The linearity range of the calibration graph was found to be 1.0−11.0 mg∙L−1 (sr ≤ 0,10, n = 5). The possibility of separate determination of iodate and periodate based on selective extraction IO4− silica modified with a quaternary ammonium salt is proposed. The metrological characteristics of the procedure were checked by means of the “entered-found” method on the control samples. The relative error did not exceed 0.10 for iodate and periodate determination on the control samples, and the relative error was not higher than ± 8.00 %. The effect of foreign ions on the iodate and periodate determination at 2.0∙10−5 mol∙L–1 has been studied. The proposed procedure is simple and suitable for iodate and periodate determination in various objects.
topic йодат
перйодат
N,N-діетиланілін
спектрофотометрія
четвертина амонійна сіль
url http://heraldchem.onu.edu.ua/article/view/94720
work_keys_str_mv AT ospogrebnyak thespectrophotometricdeterminationofnitriteswithnndiethylaniline
AT ospogrebnyak spectrophotometricdeterminationofnitriteswithnndiethylaniline
_version_ 1716784401614897152