Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification
Aim: To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software. Design: Prospective, randomized clinical trial. Methods: AquaLase was used in the right eye and NeoSoniX in the...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Palacký University Olomouc, Faculty of Medicine and Dentistry
2016-03-01
|
Series: | Biomedical Papers |
Subjects: | |
Online Access: | https://biomed.papers.upol.cz/artkey/bio-201601-0020_Long-term_follow-up_of_posterior_capsule_opacification_after_AquaLase_and_NeoSoniX_phacoemulsification.php |
id |
doaj-9d1a43a641b84d749b18e0565877ffef |
---|---|
record_format |
Article |
spelling |
doaj-9d1a43a641b84d749b18e0565877ffef2020-11-25T03:48:30ZengPalacký University Olomouc, Faculty of Medicine and DentistryBiomedical Papers1213-81181804-75212016-03-01160114314810.5507/bp.2015.039bio-201601-0020Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsificationAlexandr Stepanov0Jana Nekolova1Nada Jiraskova2Pavel Rozsival3Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech RepublicDepartment of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech RepublicDepartment of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech RepublicDepartment of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech RepublicAim: To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software. Design: Prospective, randomized clinical trial. Methods: AquaLase was used in the right eye and NeoSoniX in the left eye of each patient with bilateral cataract. Results: Fifty patients were analyzed 1 year, 46 patients 3 years, and 37 patients 8 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 ± 0.305 and for the NeoSoniX group 0.298 ± 0.341 (P = 0.53) 1 year after surgery, for the AquaLase group 0.582 ± 0.506 and for the NeoSoniX group 0.594 ± 0.515 (P = 0.87) 3 years after surgery, and for the AquaLase group 0.648 ± 0.567 and for the NeoSoniX group 0.673 ± 0.542 (P = 0.30) 8 years after surgery. The OSCA results were for the AquaLase group 0.7097 ± 0.3778 and for the NeoSoniX group 0.8584 ± 0.4323 (P = 0.046) 1 year after surgery, for the AquaLase group 0.9667 ± 0.736 and for the NeoSoniX group 0.9540 ± 0.5250 (P = 0.91) 3 years after surgery, and for the AquaLase group 1,035 ± 0,952 and for the NeoSoniX group 1,103 ± 0,741 (P = 0.44) 8 years after surgery. Conclusion: There was minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.https://biomed.papers.upol.cz/artkey/bio-201601-0020_Long-term_follow-up_of_posterior_capsule_opacification_after_AquaLase_and_NeoSoniX_phacoemulsification.phpposterior capsule opacificationaqualaseneosonix |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Alexandr Stepanov Jana Nekolova Nada Jiraskova Pavel Rozsival |
spellingShingle |
Alexandr Stepanov Jana Nekolova Nada Jiraskova Pavel Rozsival Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification Biomedical Papers posterior capsule opacification aqualase neosonix |
author_facet |
Alexandr Stepanov Jana Nekolova Nada Jiraskova Pavel Rozsival |
author_sort |
Alexandr Stepanov |
title |
Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification |
title_short |
Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification |
title_full |
Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification |
title_fullStr |
Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification |
title_full_unstemmed |
Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification |
title_sort |
long-term follow-up of posterior capsule opacification after aqualase and neosonix phacoemulsification |
publisher |
Palacký University Olomouc, Faculty of Medicine and Dentistry |
series |
Biomedical Papers |
issn |
1213-8118 1804-7521 |
publishDate |
2016-03-01 |
description |
Aim: To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software.
Design: Prospective, randomized clinical trial.
Methods: AquaLase was used in the right eye and NeoSoniX in the left eye of each patient with bilateral cataract.
Results: Fifty patients were analyzed 1 year, 46 patients 3 years, and 37 patients 8 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 ± 0.305 and for the NeoSoniX group 0.298 ± 0.341 (P = 0.53) 1 year after surgery, for the AquaLase group 0.582 ± 0.506 and for the NeoSoniX group 0.594 ± 0.515 (P = 0.87) 3 years after surgery, and for the AquaLase group 0.648 ± 0.567 and for the NeoSoniX group 0.673 ± 0.542 (P = 0.30) 8 years after surgery. The OSCA results were for the AquaLase group 0.7097 ± 0.3778 and for the NeoSoniX group 0.8584 ± 0.4323 (P = 0.046) 1 year after surgery, for the AquaLase group 0.9667 ± 0.736 and for the NeoSoniX group 0.9540 ± 0.5250 (P = 0.91) 3 years after surgery, and for the AquaLase group 1,035 ± 0,952 and for the NeoSoniX group 1,103 ± 0,741 (P = 0.44) 8 years after surgery.
Conclusion: There was minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO. |
topic |
posterior capsule opacification aqualase neosonix |
url |
https://biomed.papers.upol.cz/artkey/bio-201601-0020_Long-term_follow-up_of_posterior_capsule_opacification_after_AquaLase_and_NeoSoniX_phacoemulsification.php |
work_keys_str_mv |
AT alexandrstepanov longtermfollowupofposteriorcapsuleopacificationafteraqualaseandneosonixphacoemulsification AT jananekolova longtermfollowupofposteriorcapsuleopacificationafteraqualaseandneosonixphacoemulsification AT nadajiraskova longtermfollowupofposteriorcapsuleopacificationafteraqualaseandneosonixphacoemulsification AT pavelrozsival longtermfollowupofposteriorcapsuleopacificationafteraqualaseandneosonixphacoemulsification |
_version_ |
1724498672032415744 |