Application of ethylene glycol in ventilation systems with variable air flow

The relevance of the use of ethylene glycol as an intermediate heat carrier in the ventilation system during the treatment of supply air is justified. A description of the operation scheme of a cooling system with an intermediate heat carrier at a variable supply air flow rate is presented. On the I...

Full description

Bibliographic Details
Main Authors: Shichkin Vitaly, Zherlykina Maria, Sheps Roman, Yaremenko Sergey
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/20/e3sconf_emmft2020_09001.pdf
id doaj-9cf9659cd5df4297b0a2392fa60760cc
record_format Article
spelling doaj-9cf9659cd5df4297b0a2392fa60760cc2021-04-06T13:47:41ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012440900110.1051/e3sconf/202124409001e3sconf_emmft2020_09001Application of ethylene glycol in ventilation systems with variable air flowShichkin Vitaly0Zherlykina Maria1Sheps Roman2Yaremenko Sergey3Voronezh State Technical UniversityVoronezh State Technical UniversityVoronezh State Technical UniversityVoronezh State Technical UniversityThe relevance of the use of ethylene glycol as an intermediate heat carrier in the ventilation system during the treatment of supply air is justified. A description of the operation scheme of a cooling system with an intermediate heat carrier at a variable supply air flow rate is presented. On the Id-diagram of the state of the humid air, the construction of air treatment processes in the central air conditioner for all purposes of the transformed room is performed. The authors have established the need for cooling and dehumidification of the supply air in all operating modes. In order to determine the maximum possible load on the elements of the building’s air conditioning system, the type of room with the highest supply air consumption was selected and the air treatment process was constructed on an Id diagram at different outdoor temperatures. A method for calculating the parameters of the cooling medium is developed and graphs are constructed that allow us to establish the relationship between the parameters of the heat exchange equipment and the purpose of the room. The regularities in the change of the parameters of the heat and cold carrier when regulating the operation of the system depending on the change in the load on it are revealed. The operating ranges of the proposed scheme of air treatment with an intermediate heat carrier in the warm period of the year with variable flow rate of the treated air and various parameters of the outdoor air are given. Based on this, the possibility of creating an algorithm for automating the ventilation system adapted for buildings of cultural and entertainment purposes is justified.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/20/e3sconf_emmft2020_09001.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Shichkin Vitaly
Zherlykina Maria
Sheps Roman
Yaremenko Sergey
spellingShingle Shichkin Vitaly
Zherlykina Maria
Sheps Roman
Yaremenko Sergey
Application of ethylene glycol in ventilation systems with variable air flow
E3S Web of Conferences
author_facet Shichkin Vitaly
Zherlykina Maria
Sheps Roman
Yaremenko Sergey
author_sort Shichkin Vitaly
title Application of ethylene glycol in ventilation systems with variable air flow
title_short Application of ethylene glycol in ventilation systems with variable air flow
title_full Application of ethylene glycol in ventilation systems with variable air flow
title_fullStr Application of ethylene glycol in ventilation systems with variable air flow
title_full_unstemmed Application of ethylene glycol in ventilation systems with variable air flow
title_sort application of ethylene glycol in ventilation systems with variable air flow
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description The relevance of the use of ethylene glycol as an intermediate heat carrier in the ventilation system during the treatment of supply air is justified. A description of the operation scheme of a cooling system with an intermediate heat carrier at a variable supply air flow rate is presented. On the Id-diagram of the state of the humid air, the construction of air treatment processes in the central air conditioner for all purposes of the transformed room is performed. The authors have established the need for cooling and dehumidification of the supply air in all operating modes. In order to determine the maximum possible load on the elements of the building’s air conditioning system, the type of room with the highest supply air consumption was selected and the air treatment process was constructed on an Id diagram at different outdoor temperatures. A method for calculating the parameters of the cooling medium is developed and graphs are constructed that allow us to establish the relationship between the parameters of the heat exchange equipment and the purpose of the room. The regularities in the change of the parameters of the heat and cold carrier when regulating the operation of the system depending on the change in the load on it are revealed. The operating ranges of the proposed scheme of air treatment with an intermediate heat carrier in the warm period of the year with variable flow rate of the treated air and various parameters of the outdoor air are given. Based on this, the possibility of creating an algorithm for automating the ventilation system adapted for buildings of cultural and entertainment purposes is justified.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/20/e3sconf_emmft2020_09001.pdf
work_keys_str_mv AT shichkinvitaly applicationofethyleneglycolinventilationsystemswithvariableairflow
AT zherlykinamaria applicationofethyleneglycolinventilationsystemswithvariableairflow
AT shepsroman applicationofethyleneglycolinventilationsystemswithvariableairflow
AT yaremenkosergey applicationofethyleneglycolinventilationsystemswithvariableairflow
_version_ 1721538022374113280