Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199

Objective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls...

Full description

Bibliographic Details
Main Authors: WU Juan, ZHANG Yaqin, WU Yunbin, CHEN Min, YU Zhou, CAO Yingping
Format: Article
Language:zho
Published: Magazine House of Cancer Research on Prevention and Treatment 2020-10-01
Series:Zhongliu Fangzhi Yanjiu
Subjects:
Online Access:http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htm
id doaj-9c2ff433b83c4e8496ec31878896e6df
record_format Article
spelling doaj-9c2ff433b83c4e8496ec31878896e6df2020-11-25T03:35:59ZzhoMagazine House of Cancer Research on Prevention and TreatmentZhongliu Fangzhi Yanjiu1000-85781000-85782020-10-01471076176510.3971/j.issn.1000-8578.2020.19.16188578.2020.19.1618Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199WU Juan0ZHANG Yaqin1WU Yunbin2CHEN Min3YU Zhou4CAO Yingping5Department of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, Fujian Medical University Union Hospital, Fuzhou 350001, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaObjective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls in three aspects of sensitivity, linearity and repeatability to evaluate their potential clinical value. Results The Ct values of S-poly(T) plus qRT-PCR method for miR-199 in healthy controls was significantly lower than that of Poly(A) qRT-PCR method (P < 0.0001); and the S-poly(T) plus qRT-PCR method had better linear correlation (P=0.0027) and repeatability (P=0.010). S-poly(T) plus qRT-PCR method had better sensitivity in detecting serum miR-199 in liver cancer patients comparing with Poly (A) qRT-PCR method. Conclusion In the detection of liver cancer serum miR-199, S-poly(T) plus qRT-PCR method is more sensitive, repeatable and stable than Poly(A) qRT-PCR.http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htmliver cancerqrt-pcrmir-199s-poly (t) plus qrt-pcr methodpoly (a) qrt-pcr method
collection DOAJ
language zho
format Article
sources DOAJ
author WU Juan
ZHANG Yaqin
WU Yunbin
CHEN Min
YU Zhou
CAO Yingping
spellingShingle WU Juan
ZHANG Yaqin
WU Yunbin
CHEN Min
YU Zhou
CAO Yingping
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
Zhongliu Fangzhi Yanjiu
liver cancer
qrt-pcr
mir-199
s-poly (t) plus qrt-pcr method
poly (a) qrt-pcr method
author_facet WU Juan
ZHANG Yaqin
WU Yunbin
CHEN Min
YU Zhou
CAO Yingping
author_sort WU Juan
title Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
title_short Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
title_full Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
title_fullStr Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
title_full_unstemmed Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
title_sort clinical value of s-poly (t) plus real-time pcr in detection of liver cancer-related mir-199
publisher Magazine House of Cancer Research on Prevention and Treatment
series Zhongliu Fangzhi Yanjiu
issn 1000-8578
1000-8578
publishDate 2020-10-01
description Objective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls in three aspects of sensitivity, linearity and repeatability to evaluate their potential clinical value. Results The Ct values of S-poly(T) plus qRT-PCR method for miR-199 in healthy controls was significantly lower than that of Poly(A) qRT-PCR method (P < 0.0001); and the S-poly(T) plus qRT-PCR method had better linear correlation (P=0.0027) and repeatability (P=0.010). S-poly(T) plus qRT-PCR method had better sensitivity in detecting serum miR-199 in liver cancer patients comparing with Poly (A) qRT-PCR method. Conclusion In the detection of liver cancer serum miR-199, S-poly(T) plus qRT-PCR method is more sensitive, repeatable and stable than Poly(A) qRT-PCR.
topic liver cancer
qrt-pcr
mir-199
s-poly (t) plus qrt-pcr method
poly (a) qrt-pcr method
url http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htm
work_keys_str_mv AT wujuan clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
AT zhangyaqin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
AT wuyunbin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
AT chenmin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
AT yuzhou clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
AT caoyingping clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199
_version_ 1724552000759136256