Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199
Objective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Magazine House of Cancer Research on Prevention and Treatment
2020-10-01
|
Series: | Zhongliu Fangzhi Yanjiu |
Subjects: | |
Online Access: | http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htm |
id |
doaj-9c2ff433b83c4e8496ec31878896e6df |
---|---|
record_format |
Article |
spelling |
doaj-9c2ff433b83c4e8496ec31878896e6df2020-11-25T03:35:59ZzhoMagazine House of Cancer Research on Prevention and TreatmentZhongliu Fangzhi Yanjiu1000-85781000-85782020-10-01471076176510.3971/j.issn.1000-8578.2020.19.16188578.2020.19.1618Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199WU Juan0ZHANG Yaqin1WU Yunbin2CHEN Min3YU Zhou4CAO Yingping5Department of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, Fujian Medical University Union Hospital, Fuzhou 350001, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaDepartment of Clinical Laboratory, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, ChinaDepartment of Clinical Laboratory, School of Medical Technology Engineering, Fujian Medical University, Fuzhou 350004, ChinaObjective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls in three aspects of sensitivity, linearity and repeatability to evaluate their potential clinical value. Results The Ct values of S-poly(T) plus qRT-PCR method for miR-199 in healthy controls was significantly lower than that of Poly(A) qRT-PCR method (P < 0.0001); and the S-poly(T) plus qRT-PCR method had better linear correlation (P=0.0027) and repeatability (P=0.010). S-poly(T) plus qRT-PCR method had better sensitivity in detecting serum miR-199 in liver cancer patients comparing with Poly (A) qRT-PCR method. Conclusion In the detection of liver cancer serum miR-199, S-poly(T) plus qRT-PCR method is more sensitive, repeatable and stable than Poly(A) qRT-PCR.http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htmliver cancerqrt-pcrmir-199s-poly (t) plus qrt-pcr methodpoly (a) qrt-pcr method |
collection |
DOAJ |
language |
zho |
format |
Article |
sources |
DOAJ |
author |
WU Juan ZHANG Yaqin WU Yunbin CHEN Min YU Zhou CAO Yingping |
spellingShingle |
WU Juan ZHANG Yaqin WU Yunbin CHEN Min YU Zhou CAO Yingping Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 Zhongliu Fangzhi Yanjiu liver cancer qrt-pcr mir-199 s-poly (t) plus qrt-pcr method poly (a) qrt-pcr method |
author_facet |
WU Juan ZHANG Yaqin WU Yunbin CHEN Min YU Zhou CAO Yingping |
author_sort |
WU Juan |
title |
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 |
title_short |
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 |
title_full |
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 |
title_fullStr |
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 |
title_full_unstemmed |
Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199 |
title_sort |
clinical value of s-poly (t) plus real-time pcr in detection of liver cancer-related mir-199 |
publisher |
Magazine House of Cancer Research on Prevention and Treatment |
series |
Zhongliu Fangzhi Yanjiu |
issn |
1000-8578 1000-8578 |
publishDate |
2020-10-01 |
description |
Objective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199. Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls in three aspects of sensitivity, linearity and repeatability to evaluate their potential clinical value. Results The Ct values of S-poly(T) plus qRT-PCR method for miR-199 in healthy controls was significantly lower than that of Poly(A) qRT-PCR method (P < 0.0001); and the S-poly(T) plus qRT-PCR method had better linear correlation (P=0.0027) and repeatability (P=0.010). S-poly(T) plus qRT-PCR method had better sensitivity in detecting serum miR-199 in liver cancer patients comparing with Poly (A) qRT-PCR method. Conclusion In the detection of liver cancer serum miR-199, S-poly(T) plus qRT-PCR method is more sensitive, repeatable and stable than Poly(A) qRT-PCR. |
topic |
liver cancer qrt-pcr mir-199 s-poly (t) plus qrt-pcr method poly (a) qrt-pcr method |
url |
http://html.rhhz.net/ZLFZYJ/html/8578.2020.19.1618.htm |
work_keys_str_mv |
AT wujuan clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 AT zhangyaqin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 AT wuyunbin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 AT chenmin clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 AT yuzhou clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 AT caoyingping clinicalvalueofspolytplusrealtimepcrindetectionoflivercancerrelatedmir199 |
_version_ |
1724552000759136256 |