Suppression of X-radiation from 2 MeV ion electrostatic accelerator
The paper presents results concerning studies of X-radiation from 2 MeV ion electrostatic accelerator “Sokol” used for nuclear microprobe analysis. The radiation protection system of the accelerator was developed and tested. Tests of the system of the accelerator show that it reduces doses rate by t...