Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation
We report the case of acute hemolysis after percutaneous transmitral valve implantation in a failed mitral valve repair. Transthoracic echocardiography revealed a high velocity mild mitral regurgitation that could be responsible for the hemolysis. The implantation of a second 26-mm SAPIEN 3 valve (E...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-07-01
|
Series: | JACC: Case Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2666084920306537 |
id |
doaj-9b41a7f10dcb4223aa7a655da2240463 |
---|---|
record_format |
Article |
spelling |
doaj-9b41a7f10dcb4223aa7a655da22404632021-06-07T06:56:39ZengElsevierJACC: Case Reports2666-08492020-07-012811241128Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring ImplantationGauthier Mouillet, MD0Romain Gallet, MD1Julien Ternacle, MD2Emmanuel Teiger, MD3Address for correspondence: Dr. Gauthier Mouillet, 51 avenue du maréchal de Lattre de Tassigny, 94010 Creteil, France.; Department of Interventional Cardiology, CHU Mondor, Créteil, FranceDepartment of Interventional Cardiology, CHU Mondor, Créteil, FranceDepartment of Interventional Cardiology, CHU Mondor, Créteil, FranceDepartment of Interventional Cardiology, CHU Mondor, Créteil, FranceWe report the case of acute hemolysis after percutaneous transmitral valve implantation in a failed mitral valve repair. Transthoracic echocardiography revealed a high velocity mild mitral regurgitation that could be responsible for the hemolysis. The implantation of a second 26-mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, California) allowed complete regression of the hemolysis. (Level of Difficulty: Intermediate.)http://www.sciencedirect.com/science/article/pii/S2666084920306537acute hemolysistranscatheter mitral valve implantationSAPIEN 3failure of mitral valve repair |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gauthier Mouillet, MD Romain Gallet, MD Julien Ternacle, MD Emmanuel Teiger, MD |
spellingShingle |
Gauthier Mouillet, MD Romain Gallet, MD Julien Ternacle, MD Emmanuel Teiger, MD Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation JACC: Case Reports acute hemolysis transcatheter mitral valve implantation SAPIEN 3 failure of mitral valve repair |
author_facet |
Gauthier Mouillet, MD Romain Gallet, MD Julien Ternacle, MD Emmanuel Teiger, MD |
author_sort |
Gauthier Mouillet, MD |
title |
Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation |
title_short |
Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation |
title_full |
Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation |
title_fullStr |
Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation |
title_full_unstemmed |
Second Percutaneous Mitral Valve Implantation to Treat Acute Hemolysis Complicating Mitral Valve in Ring Implantation |
title_sort |
second percutaneous mitral valve implantation to treat acute hemolysis complicating mitral valve in ring implantation |
publisher |
Elsevier |
series |
JACC: Case Reports |
issn |
2666-0849 |
publishDate |
2020-07-01 |
description |
We report the case of acute hemolysis after percutaneous transmitral valve implantation in a failed mitral valve repair. Transthoracic echocardiography revealed a high velocity mild mitral regurgitation that could be responsible for the hemolysis. The implantation of a second 26-mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, California) allowed complete regression of the hemolysis. (Level of Difficulty: Intermediate.) |
topic |
acute hemolysis transcatheter mitral valve implantation SAPIEN 3 failure of mitral valve repair |
url |
http://www.sciencedirect.com/science/article/pii/S2666084920306537 |
work_keys_str_mv |
AT gauthiermouilletmd secondpercutaneousmitralvalveimplantationtotreatacutehemolysiscomplicatingmitralvalveinringimplantation AT romaingalletmd secondpercutaneousmitralvalveimplantationtotreatacutehemolysiscomplicatingmitralvalveinringimplantation AT julienternaclemd secondpercutaneousmitralvalveimplantationtotreatacutehemolysiscomplicatingmitralvalveinringimplantation AT emmanuelteigermd secondpercutaneousmitralvalveimplantationtotreatacutehemolysiscomplicatingmitralvalveinringimplantation |
_version_ |
1721391844959453184 |