Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel

The aim of the paper is to estimate effect of the heating surface enhancement on FC-72 flow boiling heat transfer for a vertical minichannel 1.7 mm deep, 24 mm wide and 360 mm long. Two types of enhanced heating surfaces were used: one with minicavities distributed unevenly, and the other with capil...

Full description

Bibliographic Details
Main Authors: Piasecka Magdalena, Strąk Kinga
Format: Article
Language:English
Published: EDP Sciences 2016-01-01
Series:EPJ Web of Conferences
Online Access:http://dx.doi.org/10.1051/epjconf/201611402095
id doaj-9abee83bdc7d4d4780c457b6cbe013d2
record_format Article
spelling doaj-9abee83bdc7d4d4780c457b6cbe013d22021-08-02T18:25:24ZengEDP SciencesEPJ Web of Conferences2100-014X2016-01-011140209510.1051/epjconf/201611402095epjconf_efm2016_02095Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannelPiasecka Magdalena0Strąk Kinga1Kielce University of Technology, Faculty of Mechatronics and Mechanical EngineeringKielce University of Technology, Faculty of Mechatronics and Mechanical EngineeringThe aim of the paper is to estimate effect of the heating surface enhancement on FC-72 flow boiling heat transfer for a vertical minichannel 1.7 mm deep, 24 mm wide and 360 mm long. Two types of enhanced heating surfaces were used: one with minicavities distributed unevenly, and the other with capillary metal fibrous structure. It was to measure temperature field on the plain side of the heating surface by means of the infrared thermography and to observe the two-phase flow patterns on the enhanced foil side. The paper analyses mainly the impact of the microstructured heating surface on the heat transfer coefficient. The results are presented as heat transfer coefficient dependences on the distance along the minichannel length. The data obtained using two types of enhanced heating surfaces in experiments was compared with the data when smooth foil as the heating surface was used. The highest local values of heat transfer coefficient were obtained using enhanced foil with minicavities - in comparison to other cases. Local values of heat transfer coefficient received for capillary fibrous structure were the lowest, even compared with data obtained for smooth foil. Probably this porous structure caused local flow disturbances.http://dx.doi.org/10.1051/epjconf/201611402095
collection DOAJ
language English
format Article
sources DOAJ
author Piasecka Magdalena
Strąk Kinga
spellingShingle Piasecka Magdalena
Strąk Kinga
Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
EPJ Web of Conferences
author_facet Piasecka Magdalena
Strąk Kinga
author_sort Piasecka Magdalena
title Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
title_short Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
title_full Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
title_fullStr Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
title_full_unstemmed Effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
title_sort effect of the heating surface enhancement on the heat transfer coefficient for a vertical minichannel
publisher EDP Sciences
series EPJ Web of Conferences
issn 2100-014X
publishDate 2016-01-01
description The aim of the paper is to estimate effect of the heating surface enhancement on FC-72 flow boiling heat transfer for a vertical minichannel 1.7 mm deep, 24 mm wide and 360 mm long. Two types of enhanced heating surfaces were used: one with minicavities distributed unevenly, and the other with capillary metal fibrous structure. It was to measure temperature field on the plain side of the heating surface by means of the infrared thermography and to observe the two-phase flow patterns on the enhanced foil side. The paper analyses mainly the impact of the microstructured heating surface on the heat transfer coefficient. The results are presented as heat transfer coefficient dependences on the distance along the minichannel length. The data obtained using two types of enhanced heating surfaces in experiments was compared with the data when smooth foil as the heating surface was used. The highest local values of heat transfer coefficient were obtained using enhanced foil with minicavities - in comparison to other cases. Local values of heat transfer coefficient received for capillary fibrous structure were the lowest, even compared with data obtained for smooth foil. Probably this porous structure caused local flow disturbances.
url http://dx.doi.org/10.1051/epjconf/201611402095
work_keys_str_mv AT piaseckamagdalena effectoftheheatingsurfaceenhancementontheheattransfercoefficientforaverticalminichannel
AT strakkinga effectoftheheatingsurfaceenhancementontheheattransfercoefficientforaverticalminichannel
_version_ 1721228223470108672