Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report

Abstract Background Congenital diaphragmatic hernia is a deficiency of the fetal diaphragm resulting in herniation of the abdominal viscera into the thoracic cavity. The best method of respiratory management of congenital diaphragmatic hernia is unclear, but high frequency oscillatory ventilation is...

Full description

Bibliographic Details
Main Authors: Sasagu Kimura, Katsuaki Toyoshima, Tomoaki Shimokaze, Rikuo Hoshino
Format: Article
Language:English
Published: BMC 2020-08-01
Series:BMC Pediatrics
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12887-020-02258-8
id doaj-9a2e40bf954048e78a452efaedcc237c
record_format Article
spelling doaj-9a2e40bf954048e78a452efaedcc237c2020-11-25T03:35:53ZengBMCBMC Pediatrics1471-24312020-08-012011610.1186/s12887-020-02258-8Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case reportSasagu Kimura0Katsuaki Toyoshima1Tomoaki Shimokaze2Rikuo Hoshino3Department of Neonatology, Kanagawa Children’s Medical CenterDepartment of Neonatology, Kanagawa Children’s Medical CenterDepartment of Neonatology, Kanagawa Children’s Medical CenterDepartment of Neonatology, Kanagawa Children’s Medical CenterAbstract Background Congenital diaphragmatic hernia is a deficiency of the fetal diaphragm resulting in herniation of the abdominal viscera into the thoracic cavity. The best method of respiratory management of congenital diaphragmatic hernia is unclear, but high frequency oscillatory ventilation is often used as the initial ventilator mode for severe congenital diaphragmatic hernia. When it becomes impossible to maintain the pre-ductal saturations, the timing of successful switching of the ventilation mode from high frequency oscillatory ventilation to conventional mechanical ventilation remains unclear. Herein, we reported two cases in which airway resistance measurements based on pulmonary function tests were used for making the decision to switch the ventilator mode from high frequency oscillatory ventilation to conventional mechanical ventilation in patients with left isolated congenital diaphragmatic hernia. Case presentation Two 0-day-old infants with congenital diaphragmatic hernia were admitted to our hospital. In both patients, high frequency oscillatory ventilation was started initially, and the levels of saturation gradually rose within a few hours after birth. After 24 h of high frequency oscillatory ventilation, the level of saturation decreased, and the dissociation of pre-ductal and post-ductal saturation re-occurred. The respiratory-system resistance was 515 and 403 cmH2O·kg/L/s, respectively. Because the respiratory-system resistance was elevated, we decided to change the ventilator mode from high frequency oscillatory ventilation to conventional mechanical ventilation. After switching to conventional mechanical ventilation, the patients’ heart rate and saturation increased immediately. Conclusions In patients with congenital diaphragmatic hernia, resistance levels of > 400 cmH2O·kg/L/s may indicate high airway resistance and suggest greater alveolar vibration attenuation. When respiratory-system resistance reaches over 400 cmH2O·kg/L/s, it may be an optimal time for switching from high frequency oscillatory ventilation to conventional mechanical ventilation.http://link.springer.com/article/10.1186/s12887-020-02258-8Conventional mechanical ventilationExtra-corporeal membrane oxygenationHigh frequency oscillatory ventilationOxygenation indexPersistent pulmonary hypertension of the newborn
collection DOAJ
language English
format Article
sources DOAJ
author Sasagu Kimura
Katsuaki Toyoshima
Tomoaki Shimokaze
Rikuo Hoshino
spellingShingle Sasagu Kimura
Katsuaki Toyoshima
Tomoaki Shimokaze
Rikuo Hoshino
Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
BMC Pediatrics
Conventional mechanical ventilation
Extra-corporeal membrane oxygenation
High frequency oscillatory ventilation
Oxygenation index
Persistent pulmonary hypertension of the newborn
author_facet Sasagu Kimura
Katsuaki Toyoshima
Tomoaki Shimokaze
Rikuo Hoshino
author_sort Sasagu Kimura
title Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
title_short Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
title_full Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
title_fullStr Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
title_full_unstemmed Using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
title_sort using airway resistance measurement to determine when to switch ventilator modes in congenital diaphragmatic hernia: a case report
publisher BMC
series BMC Pediatrics
issn 1471-2431
publishDate 2020-08-01
description Abstract Background Congenital diaphragmatic hernia is a deficiency of the fetal diaphragm resulting in herniation of the abdominal viscera into the thoracic cavity. The best method of respiratory management of congenital diaphragmatic hernia is unclear, but high frequency oscillatory ventilation is often used as the initial ventilator mode for severe congenital diaphragmatic hernia. When it becomes impossible to maintain the pre-ductal saturations, the timing of successful switching of the ventilation mode from high frequency oscillatory ventilation to conventional mechanical ventilation remains unclear. Herein, we reported two cases in which airway resistance measurements based on pulmonary function tests were used for making the decision to switch the ventilator mode from high frequency oscillatory ventilation to conventional mechanical ventilation in patients with left isolated congenital diaphragmatic hernia. Case presentation Two 0-day-old infants with congenital diaphragmatic hernia were admitted to our hospital. In both patients, high frequency oscillatory ventilation was started initially, and the levels of saturation gradually rose within a few hours after birth. After 24 h of high frequency oscillatory ventilation, the level of saturation decreased, and the dissociation of pre-ductal and post-ductal saturation re-occurred. The respiratory-system resistance was 515 and 403 cmH2O·kg/L/s, respectively. Because the respiratory-system resistance was elevated, we decided to change the ventilator mode from high frequency oscillatory ventilation to conventional mechanical ventilation. After switching to conventional mechanical ventilation, the patients’ heart rate and saturation increased immediately. Conclusions In patients with congenital diaphragmatic hernia, resistance levels of > 400 cmH2O·kg/L/s may indicate high airway resistance and suggest greater alveolar vibration attenuation. When respiratory-system resistance reaches over 400 cmH2O·kg/L/s, it may be an optimal time for switching from high frequency oscillatory ventilation to conventional mechanical ventilation.
topic Conventional mechanical ventilation
Extra-corporeal membrane oxygenation
High frequency oscillatory ventilation
Oxygenation index
Persistent pulmonary hypertension of the newborn
url http://link.springer.com/article/10.1186/s12887-020-02258-8
work_keys_str_mv AT sasagukimura usingairwayresistancemeasurementtodeterminewhentoswitchventilatormodesincongenitaldiaphragmaticherniaacasereport
AT katsuakitoyoshima usingairwayresistancemeasurementtodeterminewhentoswitchventilatormodesincongenitaldiaphragmaticherniaacasereport
AT tomoakishimokaze usingairwayresistancemeasurementtodeterminewhentoswitchventilatormodesincongenitaldiaphragmaticherniaacasereport
AT rikuohoshino usingairwayresistancemeasurementtodeterminewhentoswitchventilatormodesincongenitaldiaphragmaticherniaacasereport
_version_ 1724552571788460032