Reference and Limit Governors for Limit Protection of Turbofan Engines

This paper proposes a novel architecture of limit protection including the references governors and limit governors and applies this architecture to limit protection in turbofan engines. References governors are designed as add-on schemes to a pre-stability engine control system that modifies refere...

Full description

Bibliographic Details
Main Authors: Wenhao Xu, Muxuan Pan, Jiakun Qin, Jinquan Huang
Format: Article
Language:English
Published: MDPI AG 2019-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/14/2803
id doaj-9a14d362b01b4e65bb04e9c0dd02c9d9
record_format Article
spelling doaj-9a14d362b01b4e65bb04e9c0dd02c9d92020-11-24T20:53:17ZengMDPI AGEnergies1996-10732019-07-011214280310.3390/en12142803en12142803Reference and Limit Governors for Limit Protection of Turbofan EnginesWenhao Xu0Muxuan Pan1Jiakun Qin2Jinquan Huang3Jiangsu Province Key Laboratory of Aerospace Power System, College of Energy & Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaJiangsu Province Key Laboratory of Aerospace Power System, College of Energy & Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaJiangsu Province Key Laboratory of Aerospace Power System, College of Energy & Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaJiangsu Province Key Laboratory of Aerospace Power System, College of Energy & Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaThis paper proposes a novel architecture of limit protection including the references governors and limit governors and applies this architecture to limit protection in turbofan engines. References governors are designed as add-on schemes to a pre-stability engine control system that modifies reference commands to avoid constraints violation. Limit governors are proposed as an assistant part for references governors adjusting constraints to prevent references from stopping updates. The use of output admissible sets for a class of variable constraints is exploited to form invariant sets. Simulation results based on a turbofan engine model show that references governors with limit governors can effectively enforce the multiple constraints and provide enhanced engine thrust when steady violation occurs.https://www.mdpi.com/1996-1073/12/14/2803turbofan enginesreference governorslimit protectionconstraint admissible set
collection DOAJ
language English
format Article
sources DOAJ
author Wenhao Xu
Muxuan Pan
Jiakun Qin
Jinquan Huang
spellingShingle Wenhao Xu
Muxuan Pan
Jiakun Qin
Jinquan Huang
Reference and Limit Governors for Limit Protection of Turbofan Engines
Energies
turbofan engines
reference governors
limit protection
constraint admissible set
author_facet Wenhao Xu
Muxuan Pan
Jiakun Qin
Jinquan Huang
author_sort Wenhao Xu
title Reference and Limit Governors for Limit Protection of Turbofan Engines
title_short Reference and Limit Governors for Limit Protection of Turbofan Engines
title_full Reference and Limit Governors for Limit Protection of Turbofan Engines
title_fullStr Reference and Limit Governors for Limit Protection of Turbofan Engines
title_full_unstemmed Reference and Limit Governors for Limit Protection of Turbofan Engines
title_sort reference and limit governors for limit protection of turbofan engines
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2019-07-01
description This paper proposes a novel architecture of limit protection including the references governors and limit governors and applies this architecture to limit protection in turbofan engines. References governors are designed as add-on schemes to a pre-stability engine control system that modifies reference commands to avoid constraints violation. Limit governors are proposed as an assistant part for references governors adjusting constraints to prevent references from stopping updates. The use of output admissible sets for a class of variable constraints is exploited to form invariant sets. Simulation results based on a turbofan engine model show that references governors with limit governors can effectively enforce the multiple constraints and provide enhanced engine thrust when steady violation occurs.
topic turbofan engines
reference governors
limit protection
constraint admissible set
url https://www.mdpi.com/1996-1073/12/14/2803
work_keys_str_mv AT wenhaoxu referenceandlimitgovernorsforlimitprotectionofturbofanengines
AT muxuanpan referenceandlimitgovernorsforlimitprotectionofturbofanengines
AT jiakunqin referenceandlimitgovernorsforlimitprotectionofturbofanengines
AT jinquanhuang referenceandlimitgovernorsforlimitprotectionofturbofanengines
_version_ 1716797587014549504