YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION
Analysis of Yogyakarta air quality based on concentration of lead particulate using Fast Neutron Activation Analysis (FNAA) method has been done. The sample was taken 3 times in 16 strategic locations of Yogyakarta city using Hi-Vol air sampler that equipped with cellulose filter TFA 2133. The sampl...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Gadjah Mada
2010-06-01
|
Series: | Indonesian Journal of Chemistry |
Online Access: | https://jurnal.ugm.ac.id/ijc/article/view/21510 |
id |
doaj-9a10fe9159bf49478f95554013f3f017 |
---|---|
record_format |
Article |
spelling |
doaj-9a10fe9159bf49478f95554013f3f0172020-11-25T00:44:10ZengUniversitas Gadjah MadaIndonesian Journal of Chemistry1411-94202460-15782010-06-019342543110.22146/ijc.2151014608YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATIONZaenal Abidin0Sunardi Sunardi1Polytechnic Institute of Nuclear Technology, Babarsari St. PoBox 6101 YKBB Yogyakarta 55281 IndonesiaCentre for Accelerator and Material Process Technology, Babarsari St. Babarsari St. PoBox 6101 YKBB Yogyakarta 55281 IndonesiaAnalysis of Yogyakarta air quality based on concentration of lead particulate using Fast Neutron Activation Analysis (FNAA) method has been done. The sample was taken 3 times in 16 strategic locations of Yogyakarta city using Hi-Vol air sampler that equipped with cellulose filter TFA 2133. The sample irradiated for 30 min with 14 MeV fast neutron and then counted using gamma spectroscopy (AccuSpec). The result indicated that concentration of Pb-208 along Diponegoro street up to Janti street respectively are minimally (0.689 - 0.775) mg/m3, and maximally: (1.598 - 1.785) mg/m3. According to DIY governor decree No. 153/2002 about the limited toxicity ambient on Yogyakarta area it is concentration that Pb. The concentration of Pb-208 are still below the permitted value of 2 mg/m3, but in certain areas, the Pb concentration is almost equal to upper limit of permitted concentration of Pb. Keywords: air borne, neutron generator, FNAAhttps://jurnal.ugm.ac.id/ijc/article/view/21510 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zaenal Abidin Sunardi Sunardi |
spellingShingle |
Zaenal Abidin Sunardi Sunardi YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION Indonesian Journal of Chemistry |
author_facet |
Zaenal Abidin Sunardi Sunardi |
author_sort |
Zaenal Abidin |
title |
YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION |
title_short |
YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION |
title_full |
YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION |
title_fullStr |
YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION |
title_full_unstemmed |
YOGYAKARTA AIR BORNE QUALITY BASED ON THE LEAD PARTICULATE CONCENTRATION |
title_sort |
yogyakarta air borne quality based on the lead particulate concentration |
publisher |
Universitas Gadjah Mada |
series |
Indonesian Journal of Chemistry |
issn |
1411-9420 2460-1578 |
publishDate |
2010-06-01 |
description |
Analysis of Yogyakarta air quality based on concentration of lead particulate using Fast Neutron Activation Analysis (FNAA) method has been done. The sample was taken 3 times in 16 strategic locations of Yogyakarta city using Hi-Vol air sampler that equipped with cellulose filter TFA 2133. The sample irradiated for 30 min with 14 MeV fast neutron and then counted using gamma spectroscopy (AccuSpec). The result indicated that concentration of Pb-208 along Diponegoro street up to Janti street respectively are minimally (0.689 - 0.775) mg/m3, and maximally: (1.598 - 1.785) mg/m3. According to DIY governor decree No. 153/2002 about the limited toxicity ambient on Yogyakarta area it is concentration that Pb. The concentration of Pb-208 are still below the permitted value of
2 mg/m3, but in certain areas, the Pb concentration is almost equal to upper limit of permitted concentration of Pb.
Keywords: air borne, neutron generator, FNAA |
url |
https://jurnal.ugm.ac.id/ijc/article/view/21510 |
work_keys_str_mv |
AT zaenalabidin yogyakartaairbornequalitybasedontheleadparticulateconcentration AT sunardisunardi yogyakartaairbornequalitybasedontheleadparticulateconcentration |
_version_ |
1716121208468013056 |