Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy

A fast and simple method for the extraction and Flame Atomic Absorption Spectroscopy (FAAS) quantification of ZnO in different cosmetic matrices, including lipsticks, water-in-oil foundations, and oil-in-water creams, was developed and validated, according to the International Council for Harmonizat...

Full description

Bibliographic Details
Main Authors: Luis F. Benavides, Juan D. Marín, Cristian Rosales, Johnbrynner García
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2021/8840723
id doaj-99e6d21a3aa04f0aac0dd5d1bda85907
record_format Article
spelling doaj-99e6d21a3aa04f0aac0dd5d1bda859072021-06-07T02:12:52ZengHindawi LimitedJournal of Analytical Methods in Chemistry2090-88732021-01-01202110.1155/2021/8840723Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption SpectroscopyLuis F. Benavides0Juan D. Marín1Cristian Rosales2Johnbrynner García3Belcorp Research and DevelopmentBelcorp Research and DevelopmentBelcorp Research and DevelopmentBelcorp Research and DevelopmentA fast and simple method for the extraction and Flame Atomic Absorption Spectroscopy (FAAS) quantification of ZnO in different cosmetic matrices, including lipsticks, water-in-oil foundations, and oil-in-water creams, was developed and validated, according to the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) and the United States Pharmacopeial Convention guidelines. The sample preparation consisted of an ultrasound-assisted ethanolic extraction of ZnO followed by digestion with 1 M nitric acid (HNO3). Samples were analyzed by Flame Atomic Absorption Spectroscopy (FAAS). Specificity, linearity, the limit of detection (LOD), the limit of quantification (LOQ), sensitivity, precision, and accuracy parameters were studied. The robustness of the method was evaluated with a five-variable Youden–Steiner model. The method was specific for ZnO, and the extraction procedure did not affect the stability of the signal compared to the background. The method was linear in the range 0.2–1.0 mg/L with LOD/LOQ values equal to 0.0156 (mg·L−1)/0.0473 (mg·L−1), 0.0098 (mg·L−1)/0.0297 (mg·L−1), 0.0113 (mg·L−1)/0.0341 (mg·L−1), and 0.0131 (mg·L−1)/0.0397 (mg·L−1), respectively, for raw material, lipstick, liquid foundation, and emulsion matrices. Regarding precision, the %RSD values were below 3.0% for repeatability and intermediate precision. Global reproducibility RSD was below 8.0% for all matrices. The percentage of recovery was not statistically different from 100% in all cases. The final concentration was found to be a critical variable for all matrices except for the raw material. The variables associated with the extraction step (ethanol volume, bath temperature, and extraction time) were critical in the extraction of liquid foundations and cream emulsions. The method reduces the number and concentration of mineral acids spent on the digestion of ZnO, and its application is extendable to raw materials. This development is an adequate tool for routine analysis and cosmetic quality control of chemically different products that contain ZnO as ultraviolet radiation (UV) filter, to guarantee regulatory compliance and ensure the safety and efficacy of products delivered to consumers.http://dx.doi.org/10.1155/2021/8840723
collection DOAJ
language English
format Article
sources DOAJ
author Luis F. Benavides
Juan D. Marín
Cristian Rosales
Johnbrynner García
spellingShingle Luis F. Benavides
Juan D. Marín
Cristian Rosales
Johnbrynner García
Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
Journal of Analytical Methods in Chemistry
author_facet Luis F. Benavides
Juan D. Marín
Cristian Rosales
Johnbrynner García
author_sort Luis F. Benavides
title Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
title_short Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
title_full Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
title_fullStr Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
title_full_unstemmed Development and Validation of a Method for the Analysis of Zinc Oxide in Cosmetic Matrices by Flame Atomic Absorption Spectroscopy
title_sort development and validation of a method for the analysis of zinc oxide in cosmetic matrices by flame atomic absorption spectroscopy
publisher Hindawi Limited
series Journal of Analytical Methods in Chemistry
issn 2090-8873
publishDate 2021-01-01
description A fast and simple method for the extraction and Flame Atomic Absorption Spectroscopy (FAAS) quantification of ZnO in different cosmetic matrices, including lipsticks, water-in-oil foundations, and oil-in-water creams, was developed and validated, according to the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) and the United States Pharmacopeial Convention guidelines. The sample preparation consisted of an ultrasound-assisted ethanolic extraction of ZnO followed by digestion with 1 M nitric acid (HNO3). Samples were analyzed by Flame Atomic Absorption Spectroscopy (FAAS). Specificity, linearity, the limit of detection (LOD), the limit of quantification (LOQ), sensitivity, precision, and accuracy parameters were studied. The robustness of the method was evaluated with a five-variable Youden–Steiner model. The method was specific for ZnO, and the extraction procedure did not affect the stability of the signal compared to the background. The method was linear in the range 0.2–1.0 mg/L with LOD/LOQ values equal to 0.0156 (mg·L−1)/0.0473 (mg·L−1), 0.0098 (mg·L−1)/0.0297 (mg·L−1), 0.0113 (mg·L−1)/0.0341 (mg·L−1), and 0.0131 (mg·L−1)/0.0397 (mg·L−1), respectively, for raw material, lipstick, liquid foundation, and emulsion matrices. Regarding precision, the %RSD values were below 3.0% for repeatability and intermediate precision. Global reproducibility RSD was below 8.0% for all matrices. The percentage of recovery was not statistically different from 100% in all cases. The final concentration was found to be a critical variable for all matrices except for the raw material. The variables associated with the extraction step (ethanol volume, bath temperature, and extraction time) were critical in the extraction of liquid foundations and cream emulsions. The method reduces the number and concentration of mineral acids spent on the digestion of ZnO, and its application is extendable to raw materials. This development is an adequate tool for routine analysis and cosmetic quality control of chemically different products that contain ZnO as ultraviolet radiation (UV) filter, to guarantee regulatory compliance and ensure the safety and efficacy of products delivered to consumers.
url http://dx.doi.org/10.1155/2021/8840723
work_keys_str_mv AT luisfbenavides developmentandvalidationofamethodfortheanalysisofzincoxideincosmeticmatricesbyflameatomicabsorptionspectroscopy
AT juandmarin developmentandvalidationofamethodfortheanalysisofzincoxideincosmeticmatricesbyflameatomicabsorptionspectroscopy
AT cristianrosales developmentandvalidationofamethodfortheanalysisofzincoxideincosmeticmatricesbyflameatomicabsorptionspectroscopy
AT johnbrynnergarcia developmentandvalidationofamethodfortheanalysisofzincoxideincosmeticmatricesbyflameatomicabsorptionspectroscopy
_version_ 1721393253802049536