Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy

In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventric...

Full description

Bibliographic Details
Main Authors: Fabio Quartieri, Daniele Giacopelli, Matteo Iori, Nicola Bottoni
Format: Article
Language:English
Published: Elsevier 2016-03-01
Series:Indian Pacing and Electrophysiology Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0972629215300188
id doaj-99da867cdd9f4ca49575d5cd20795c34
record_format Article
spelling doaj-99da867cdd9f4ca49575d5cd20795c342020-11-24T22:36:06ZengElsevierIndian Pacing and Electrophysiology Journal0972-62922016-03-01162707210.1016/j.ipej.2016.08.004Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopyFabio Quartieri0Daniele Giacopelli1Matteo Iori2Nicola Bottoni3Cardiologia Interventistica, Arcispedale Santa Maria Nuova, Reggio Emilia (RE), ItalyBiotronik Italia, Clinical Research, Milano, ItalyCardiologia Interventistica, Arcispedale Santa Maria Nuova, Reggio Emilia (RE), ItalyCardiologia Interventistica, Arcispedale Santa Maria Nuova, Reggio Emilia (RE), ItalyIn this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated.http://www.sciencedirect.com/science/article/pii/S0972629215300188Implantable cardioverter defibrillatorPregnancyElectro-anatomic mappingNon-fluoroscopy imaging
collection DOAJ
language English
format Article
sources DOAJ
author Fabio Quartieri
Daniele Giacopelli
Matteo Iori
Nicola Bottoni
spellingShingle Fabio Quartieri
Daniele Giacopelli
Matteo Iori
Nicola Bottoni
Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
Indian Pacing and Electrophysiology Journal
Implantable cardioverter defibrillator
Pregnancy
Electro-anatomic mapping
Non-fluoroscopy imaging
author_facet Fabio Quartieri
Daniele Giacopelli
Matteo Iori
Nicola Bottoni
author_sort Fabio Quartieri
title Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_short Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_full Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_fullStr Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_full_unstemmed Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_sort implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
publisher Elsevier
series Indian Pacing and Electrophysiology Journal
issn 0972-6292
publishDate 2016-03-01
description In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated.
topic Implantable cardioverter defibrillator
Pregnancy
Electro-anatomic mapping
Non-fluoroscopy imaging
url http://www.sciencedirect.com/science/article/pii/S0972629215300188
work_keys_str_mv AT fabioquartieri implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT danielegiacopelli implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT matteoiori implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT nicolabottoni implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
_version_ 1725721355914051584