Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model
Poiseuille’s equation describes the relationship between fluid viscosity, pressure, tubing diameter, and flow, yet it is not known if cold organ perfusion systems follow this equation. We investigated these relationships in an ex vivo model and aimed to offer some rationale for equipment selection....
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2013-01-01
|
Series: | Journal of Transplantation |
Online Access: | http://dx.doi.org/10.1155/2013/605326 |
id |
doaj-99d7d1a588d249e8a4e2e6e63b0bc2d9 |
---|---|
record_format |
Article |
spelling |
doaj-99d7d1a588d249e8a4e2e6e63b0bc2d92020-11-24T23:41:26ZengHindawi LimitedJournal of Transplantation2090-00072090-00152013-01-01201310.1155/2013/605326605326Beyond Poiseuille: Preservation Fluid Flow in an Experimental ModelSaurabh Singh0Lucy V. Randle1Paul T. Callaghan2Christopher J. E. Watson3Chris J. Callaghan4University Department of Surgery, Addenbrooke’s Hospital, NIHR Comprehensive Biomedical Research Centre, Cambridge CB2 0QQ, UKUniversity Department of Surgery, Addenbrooke’s Hospital, NIHR Comprehensive Biomedical Research Centre, Cambridge CB2 0QQ, UKSchool of Chemical and Physical Sciences, Victoria University of Wellington, Wellington, New ZealandUniversity Department of Surgery, Addenbrooke’s Hospital, NIHR Comprehensive Biomedical Research Centre, Cambridge CB2 0QQ, UKDepartment of Renal Surgery, Guy’s Hospital, London SE1 9RT, UKPoiseuille’s equation describes the relationship between fluid viscosity, pressure, tubing diameter, and flow, yet it is not known if cold organ perfusion systems follow this equation. We investigated these relationships in an ex vivo model and aimed to offer some rationale for equipment selection. Increasing the cannula size from 14 to 20 Fr increased flow rate by a mean (SD) of 13 (12)%. Marshall’s hyperosmolar citrate was three times less viscous than UW solution, but flows were only 45% faster. Doubling the bag pressure led to a mean (SD) flow rate increase of only 19 (13)%, not twice the rate. When external pressure devices were used, 100 mmHg of continuous pressure increased flow by a mean (SD) of 43 (17)% when compared to the same pressure applied initially only. Poiseuille’s equation was not followed; this is most likely due to “slipping” of preservation fluid within the plastic tubing. Cannula size made little difference over the ranges examined; flows are primarily determined by bag pressure and fluid viscosity. External infusor devices require continuous pressurisation to deliver high flow. Future studies examining the impact of perfusion variables on graft outcomes should include detailed equipment descriptions.http://dx.doi.org/10.1155/2013/605326 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Saurabh Singh Lucy V. Randle Paul T. Callaghan Christopher J. E. Watson Chris J. Callaghan |
spellingShingle |
Saurabh Singh Lucy V. Randle Paul T. Callaghan Christopher J. E. Watson Chris J. Callaghan Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model Journal of Transplantation |
author_facet |
Saurabh Singh Lucy V. Randle Paul T. Callaghan Christopher J. E. Watson Chris J. Callaghan |
author_sort |
Saurabh Singh |
title |
Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model |
title_short |
Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model |
title_full |
Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model |
title_fullStr |
Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model |
title_full_unstemmed |
Beyond Poiseuille: Preservation Fluid Flow in an Experimental Model |
title_sort |
beyond poiseuille: preservation fluid flow in an experimental model |
publisher |
Hindawi Limited |
series |
Journal of Transplantation |
issn |
2090-0007 2090-0015 |
publishDate |
2013-01-01 |
description |
Poiseuille’s equation describes the relationship between fluid viscosity, pressure, tubing diameter, and flow, yet it is not known if cold organ perfusion systems follow this equation. We investigated these relationships in an ex vivo model and aimed to offer some rationale for equipment selection. Increasing the cannula size from 14 to 20 Fr increased flow rate by a mean (SD) of 13 (12)%. Marshall’s hyperosmolar citrate was three times less viscous than UW solution, but flows were only 45% faster. Doubling the bag pressure led to a mean (SD) flow rate increase of only 19 (13)%, not twice the rate. When external pressure devices were used, 100 mmHg of continuous pressure increased flow by a mean (SD) of 43 (17)% when compared to the same pressure applied initially only. Poiseuille’s equation was not followed; this is most likely due to “slipping” of preservation fluid within the plastic tubing. Cannula size made little difference over the ranges examined; flows are primarily determined by bag pressure and fluid viscosity. External infusor devices require continuous pressurisation to deliver high flow. Future studies examining the impact of perfusion variables on graft outcomes should include detailed equipment descriptions. |
url |
http://dx.doi.org/10.1155/2013/605326 |
work_keys_str_mv |
AT saurabhsingh beyondpoiseuillepreservationfluidflowinanexperimentalmodel AT lucyvrandle beyondpoiseuillepreservationfluidflowinanexperimentalmodel AT paultcallaghan beyondpoiseuillepreservationfluidflowinanexperimentalmodel AT christopherjewatson beyondpoiseuillepreservationfluidflowinanexperimentalmodel AT chrisjcallaghan beyondpoiseuillepreservationfluidflowinanexperimentalmodel |
_version_ |
1725507368260730880 |