Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations

The development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand mag...

Full description

Bibliographic Details
Main Author: Zeńczak Michał
Format: Article
Language:English
Published: Polish Academy of Sciences 2016-06-01
Series:Archives of Electrical Engineering
Subjects:
Online Access:http://www.degruyter.com/view/j/aee.2016.65.issue-2/aee-2016-0021/aee-2016-0021.xml?format=INT
id doaj-99d11b3ea9774c22aaf1952ab136e1dc
record_format Article
spelling doaj-99d11b3ea9774c22aaf1952ab136e1dc2020-11-25T03:09:22ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062016-06-0165229530410.1515/aee-2016-0021aee-2016-0021Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generationsZeńczak Michał0West Pomeranian University of Technology, Szczecin Faculty of Electrical Engeneering Al. Piastów 17, 70-310, Szczecin, PolandThe development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand magnetic field intensity may prove essential. The main aim of the paper is to present a method estimating the “ballast” of the natural environment at 50 Hz electric and magnetic fields in the power system, with distributed and centralized generation in real operating conditions.http://www.degruyter.com/view/j/aee.2016.65.issue-2/aee-2016-0021/aee-2016-0021.xml?format=INTdistributed generationelectric fieldmagnetic fieldpower line
collection DOAJ
language English
format Article
sources DOAJ
author Zeńczak Michał
spellingShingle Zeńczak Michał
Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
Archives of Electrical Engineering
distributed generation
electric field
magnetic field
power line
author_facet Zeńczak Michał
author_sort Zeńczak Michał
title Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
title_short Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
title_full Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
title_fullStr Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
title_full_unstemmed Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
title_sort method of estimating the exposure of the natural environment to 50 hz electric and magnetic fields in power systems with distributed and centralized generations
publisher Polish Academy of Sciences
series Archives of Electrical Engineering
issn 2300-2506
publishDate 2016-06-01
description The development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand magnetic field intensity may prove essential. The main aim of the paper is to present a method estimating the “ballast” of the natural environment at 50 Hz electric and magnetic fields in the power system, with distributed and centralized generation in real operating conditions.
topic distributed generation
electric field
magnetic field
power line
url http://www.degruyter.com/view/j/aee.2016.65.issue-2/aee-2016-0021/aee-2016-0021.xml?format=INT
work_keys_str_mv AT zenczakmichał methodofestimatingtheexposureofthenaturalenvironmentto50hzelectricandmagneticfieldsinpowersystemswithdistributedandcentralizedgenerations
_version_ 1724663060524695552