Influence of Topography on 3D printed Titanium Foot and Ankle Implants

Category: Basic Sciences/Biologics; Ankle; Trauma Introduction/Purpose Foot and ankle etiologies such as traumatic fractures, Charcot Arthropathy, nonunion after high risk arthrodesis and infectious debridement can result in critical sized bone defect (CSD). CSD is defined as bone loss greater than...

Full description

Bibliographic Details
Main Authors: Bijan Abar, Cambre N. Kelly, Nicholas B. Allen, Helena Barber, Alexander P. Kelly, Ken Gall, Samuel B. Adams MD
Format: Article
Language:English
Published: SAGE Publishing 2020-10-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011420S00016
id doaj-99793a38d83940f7b90aaf35891b5f9e
record_format Article
spelling doaj-99793a38d83940f7b90aaf35891b5f9e2020-11-25T04:07:02ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142020-10-01510.1177/2473011420S00016Influence of Topography on 3D printed Titanium Foot and Ankle ImplantsBijan AbarCambre N. KellyNicholas B. AllenHelena BarberAlexander P. KellyKen GallSamuel B. Adams MDCategory: Basic Sciences/Biologics; Ankle; Trauma Introduction/Purpose Foot and ankle etiologies such as traumatic fractures, Charcot Arthropathy, nonunion after high risk arthrodesis and infectious debridement can result in critical sized bone defect (CSD). CSD is defined as bone loss greater than 1-2 cm in length or greater than 50% loss in circumference of bone. CSD remain a significant challenge in Orthopaedics. Custom 3D printed porous Titanium implants are currently being implemented when allograft is not an option. However, in a subset of cases, Titanium implants need to be removed due to infection or poor osseous integration where surrounding bone does not grow onto or through the scaffold. There is no one clear reason for poor osseous integration. This study explores effects of 3D printed topography on mechanical and biological properties. Methods: Titanium dog bones and discs were printed via laser powder bed fusion. Roughness groups were polished, blasted, as built, sprouts and rough sprouts. Roughness was measured with line measurement using a confocal microscope. To assess mechanical properties, tensile testing of samples from each roughness group produced stress strain curves. MC3T3 preosteoblast were seeded on discs. Samples were analyzed at 0, 2, and 4 weeks. A cell viability assay and confocal florescent microscopy assessed cell growth. Alkaline Phosphatase (ALP) assay and Quantitative Polymerase Chain Reaction (qPCR) examined cell differentiation. Extracellular matrix (ECM) was stained for collagen and calcium. Scanning Electron Microcopy (SEM) was done on sputter coated discs. Results: Rz, maximum peak to valley distance of the sample profile, for the polished, blasted, as built, sprouts and rough sprouts were 2.6, 22.6, 33.0, 41.4 and 65.1 µm respectively. The addition of printed roughness in the sprouts and rough sprouts group significantly diminished ductility resulting in early strain to failure during tensile testing. Cells adhered and proliferated on discs regardless of roughness group. There was no statically difference in ALP activity, but qPCR showed that rough groups (sprouts and rough sprouts) had diminished Osteocalcin gene expression at week 2 and 4. The ECM observed with SEM in the rough groups was more resistant to repeated washes and was more extensive compared to the less rough groups. Conclusion: The addition of 3D printed artificial roughness leads to inferior mechanical properties and confers no clear benefit regarding cellular proliferation. Printed topography increases the initiation of fractures resulting in diminished tensile strength and ductility. Concurrently, the resolution of LBF is not fine enough at this time to create surface features that enhance cell behavior. Therefore, data in this study suggest that artificially printing roughness is not an effective strategy to enhance osseous integration into Titanium implants for critical sized defects.https://doi.org/10.1177/2473011420S00016
collection DOAJ
language English
format Article
sources DOAJ
author Bijan Abar
Cambre N. Kelly
Nicholas B. Allen
Helena Barber
Alexander P. Kelly
Ken Gall
Samuel B. Adams MD
spellingShingle Bijan Abar
Cambre N. Kelly
Nicholas B. Allen
Helena Barber
Alexander P. Kelly
Ken Gall
Samuel B. Adams MD
Influence of Topography on 3D printed Titanium Foot and Ankle Implants
Foot & Ankle Orthopaedics
author_facet Bijan Abar
Cambre N. Kelly
Nicholas B. Allen
Helena Barber
Alexander P. Kelly
Ken Gall
Samuel B. Adams MD
author_sort Bijan Abar
title Influence of Topography on 3D printed Titanium Foot and Ankle Implants
title_short Influence of Topography on 3D printed Titanium Foot and Ankle Implants
title_full Influence of Topography on 3D printed Titanium Foot and Ankle Implants
title_fullStr Influence of Topography on 3D printed Titanium Foot and Ankle Implants
title_full_unstemmed Influence of Topography on 3D printed Titanium Foot and Ankle Implants
title_sort influence of topography on 3d printed titanium foot and ankle implants
publisher SAGE Publishing
series Foot & Ankle Orthopaedics
issn 2473-0114
publishDate 2020-10-01
description Category: Basic Sciences/Biologics; Ankle; Trauma Introduction/Purpose Foot and ankle etiologies such as traumatic fractures, Charcot Arthropathy, nonunion after high risk arthrodesis and infectious debridement can result in critical sized bone defect (CSD). CSD is defined as bone loss greater than 1-2 cm in length or greater than 50% loss in circumference of bone. CSD remain a significant challenge in Orthopaedics. Custom 3D printed porous Titanium implants are currently being implemented when allograft is not an option. However, in a subset of cases, Titanium implants need to be removed due to infection or poor osseous integration where surrounding bone does not grow onto or through the scaffold. There is no one clear reason for poor osseous integration. This study explores effects of 3D printed topography on mechanical and biological properties. Methods: Titanium dog bones and discs were printed via laser powder bed fusion. Roughness groups were polished, blasted, as built, sprouts and rough sprouts. Roughness was measured with line measurement using a confocal microscope. To assess mechanical properties, tensile testing of samples from each roughness group produced stress strain curves. MC3T3 preosteoblast were seeded on discs. Samples were analyzed at 0, 2, and 4 weeks. A cell viability assay and confocal florescent microscopy assessed cell growth. Alkaline Phosphatase (ALP) assay and Quantitative Polymerase Chain Reaction (qPCR) examined cell differentiation. Extracellular matrix (ECM) was stained for collagen and calcium. Scanning Electron Microcopy (SEM) was done on sputter coated discs. Results: Rz, maximum peak to valley distance of the sample profile, for the polished, blasted, as built, sprouts and rough sprouts were 2.6, 22.6, 33.0, 41.4 and 65.1 µm respectively. The addition of printed roughness in the sprouts and rough sprouts group significantly diminished ductility resulting in early strain to failure during tensile testing. Cells adhered and proliferated on discs regardless of roughness group. There was no statically difference in ALP activity, but qPCR showed that rough groups (sprouts and rough sprouts) had diminished Osteocalcin gene expression at week 2 and 4. The ECM observed with SEM in the rough groups was more resistant to repeated washes and was more extensive compared to the less rough groups. Conclusion: The addition of 3D printed artificial roughness leads to inferior mechanical properties and confers no clear benefit regarding cellular proliferation. Printed topography increases the initiation of fractures resulting in diminished tensile strength and ductility. Concurrently, the resolution of LBF is not fine enough at this time to create surface features that enhance cell behavior. Therefore, data in this study suggest that artificially printing roughness is not an effective strategy to enhance osseous integration into Titanium implants for critical sized defects.
url https://doi.org/10.1177/2473011420S00016
work_keys_str_mv AT bijanabar influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT cambrenkelly influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT nicholasballen influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT helenabarber influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT alexanderpkelly influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT kengall influenceoftopographyon3dprintedtitaniumfootandankleimplants
AT samuelbadamsmd influenceoftopographyon3dprintedtitaniumfootandankleimplants
_version_ 1724429784771985408