Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging
Abstract Background Numerous self-gated cardiac imaging techniques have been reported in the literature. Most can track either cardiac or respiratory motion, and many incur some overhead to imaging data acquisition. We previously described a Cartesian cine imaging technique, pseudo-projection motion...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2019-04-01
|
Series: | Journal of Cardiovascular Magnetic Resonance |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s12968-019-0533-8 |
id |
doaj-9958cd9e449543bb926da4f36a08b9e4 |
---|---|
record_format |
Article |
spelling |
doaj-9958cd9e449543bb926da4f36a08b9e42020-11-25T02:37:37ZengBMCJournal of Cardiovascular Magnetic Resonance1532-429X2019-04-0121111510.1186/s12968-019-0533-8Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imagingLiheng Guo0Daniel A. Herzka1Department of Biomedical Engineering, Johns Hopkins University School of MedicineDepartment of Biomedical Engineering, Johns Hopkins University School of MedicineAbstract Background Numerous self-gated cardiac imaging techniques have been reported in the literature. Most can track either cardiac or respiratory motion, and many incur some overhead to imaging data acquisition. We previously described a Cartesian cine imaging technique, pseudo-projection motion tracking with golden-step phase encoding, capable of tracking both cardiac and respiratory motion at no cost to imaging data acquisition. In this work, we describe improvements to the technique by dramatically reducing its vulnerability to eddy current and flow artifacts and demonstrating its effectiveness in expanded cardiovascular applications. Methods As with our previous golden-step technique, the Cartesian phase encodes over time were arranged based on the integer golden step, and readouts near k y = 0 (pseudo-projections) were used to derive motion. In this work, however, the readouts were divided into equal and consecutive temporal segments, within which the readouts were sorted according to k y . The sorting reduces the phase encode jump between consecutive readouts while maintaining the pseudo-randomness of k y to sample both cardiac and respiratory motion without comprising the ability to retrospectively set the temporal resolution of the original technique. On human volunteers, free-breathing, electrocardiographic (ECG)-free cine scans were acquired for all slices of the short axis stack and the 4-chamber view of the long axis. Retrospectively, cardiac motion and respiratory motion were automatically extracted from the pseudo-projections to guide cine reconstruction. The resultant image quality in terms of sharpness and cardiac functional metrics was compared against breath-hold ECG-gated reference cines. Results With sorting, motion tracking of both cardiac and respiratory motion was effective for all slices orientations imaged, and artifact occurrence due to eddy current and flow was efficiently eliminated. The image sharpness derived from the self-gated cines was found to be comparable to the reference cines (mean difference less than 0.05 mm− 1 for short-axis images and 0.075 mm− 1 for long-axis images), and the functional metrics (mean difference < 4 ml) were found not to be statistically different from those from the reference. Conclusions This technique dramatically reduced the eddy current and flow artifacts while preserving the ability of cost-free motion tracking and the flexibility of choosing arbitrary navigator zone width, number of cardiac phases, and duration of scanning. With the restriction of the artifacts removed, the Cartesian golden-step cine imaging can now be applied to cardiac imaging slices of more diverse orientation and anatomy at greater reliability.http://link.springer.com/article/10.1186/s12968-019-0533-8Golden stepSelf-navigationSelf-gatingMotion trackingPseudo-projectionsCine imaging |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Liheng Guo Daniel A. Herzka |
spellingShingle |
Liheng Guo Daniel A. Herzka Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging Journal of Cardiovascular Magnetic Resonance Golden step Self-navigation Self-gating Motion tracking Pseudo-projections Cine imaging |
author_facet |
Liheng Guo Daniel A. Herzka |
author_sort |
Liheng Guo |
title |
Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
title_short |
Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
title_full |
Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
title_fullStr |
Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
title_full_unstemmed |
Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
title_sort |
sorted golden-step phase encoding: an improved golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging |
publisher |
BMC |
series |
Journal of Cardiovascular Magnetic Resonance |
issn |
1532-429X |
publishDate |
2019-04-01 |
description |
Abstract Background Numerous self-gated cardiac imaging techniques have been reported in the literature. Most can track either cardiac or respiratory motion, and many incur some overhead to imaging data acquisition. We previously described a Cartesian cine imaging technique, pseudo-projection motion tracking with golden-step phase encoding, capable of tracking both cardiac and respiratory motion at no cost to imaging data acquisition. In this work, we describe improvements to the technique by dramatically reducing its vulnerability to eddy current and flow artifacts and demonstrating its effectiveness in expanded cardiovascular applications. Methods As with our previous golden-step technique, the Cartesian phase encodes over time were arranged based on the integer golden step, and readouts near k y = 0 (pseudo-projections) were used to derive motion. In this work, however, the readouts were divided into equal and consecutive temporal segments, within which the readouts were sorted according to k y . The sorting reduces the phase encode jump between consecutive readouts while maintaining the pseudo-randomness of k y to sample both cardiac and respiratory motion without comprising the ability to retrospectively set the temporal resolution of the original technique. On human volunteers, free-breathing, electrocardiographic (ECG)-free cine scans were acquired for all slices of the short axis stack and the 4-chamber view of the long axis. Retrospectively, cardiac motion and respiratory motion were automatically extracted from the pseudo-projections to guide cine reconstruction. The resultant image quality in terms of sharpness and cardiac functional metrics was compared against breath-hold ECG-gated reference cines. Results With sorting, motion tracking of both cardiac and respiratory motion was effective for all slices orientations imaged, and artifact occurrence due to eddy current and flow was efficiently eliminated. The image sharpness derived from the self-gated cines was found to be comparable to the reference cines (mean difference less than 0.05 mm− 1 for short-axis images and 0.075 mm− 1 for long-axis images), and the functional metrics (mean difference < 4 ml) were found not to be statistically different from those from the reference. Conclusions This technique dramatically reduced the eddy current and flow artifacts while preserving the ability of cost-free motion tracking and the flexibility of choosing arbitrary navigator zone width, number of cardiac phases, and duration of scanning. With the restriction of the artifacts removed, the Cartesian golden-step cine imaging can now be applied to cardiac imaging slices of more diverse orientation and anatomy at greater reliability. |
topic |
Golden step Self-navigation Self-gating Motion tracking Pseudo-projections Cine imaging |
url |
http://link.springer.com/article/10.1186/s12968-019-0533-8 |
work_keys_str_mv |
AT lihengguo sortedgoldenstepphaseencodinganimprovedgoldenstepimagingtechniqueforcardiacandrespiratoryselfgatedcinecardiovascularmagneticresonanceimaging AT danielaherzka sortedgoldenstepphaseencodinganimprovedgoldenstepimagingtechniqueforcardiacandrespiratoryselfgatedcinecardiovascularmagneticresonanceimaging |
_version_ |
1724794382864875520 |