Summary: | The construction industry has made considerable energy-saving efforts in buildings, and studies of energy-savings are ongoing. Shading is used to control the solar radiation transferred through windows. Many studies have examined the position and type of shading in different countries, but few have investigated the effects of shading installation in Korea. In this study, the case of the shading installation according to the standard of Korea, and variations of the heating and cooling load in the unit area on the performance of the windows were examined. This study compared the variations of the heating and cooling load in the case of horizontal shading and the changing position of venetian blinds. This study confirmed that horizontal shading longer than the standard length in Korea saved a maximum of 13% energy consumption. This study confirmed the point of change of energy consumption by the Solar Heat Gain Coefficient (SHGC) variations. The exterior venetian blinds and those between glazing were unaffected by the SHGC. On the other hand, in the case of a south façade, the interior venetian blinds resulted in 24% higher energy consumption than the installation of horizontal shading in case of Window to Wall Ratio (WWR): 80%, U-value: 2.1 and SHGC: 0.4.
|