Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector

Practical analytic equations, for the ideal field, and numerical results from SIMION simulations, for the fringing field, are presented for the exit radius rπ and transit time tπ of electrons in a hemispherical deflector analyzer (HDA) over a wide range of analyzer parameters. Results are presented...

Full description

Bibliographic Details
Main Authors: Omer Sise, Theo J. M. Zouros
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:Journal of Spectroscopy
Online Access:http://dx.doi.org/10.1155/2015/153513
id doaj-96f9c98a36d74f7188c7ead58b87c57d
record_format Article
spelling doaj-96f9c98a36d74f7188c7ead58b87c57d2020-11-24T23:12:51ZengHindawi LimitedJournal of Spectroscopy2314-49202314-49392015-01-01201510.1155/2015/153513153513Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive DetectorOmer Sise0Theo J. M. Zouros1Department of Science Education, Faculty of Education, Suleyman Demirel University, 32260 Isparta, TurkeyDepartment of Physics, University of Crete, P.O. Box 2208, 71003 Heraklion, GreecePractical analytic equations, for the ideal field, and numerical results from SIMION simulations, for the fringing field, are presented for the exit radius rπ and transit time tπ of electrons in a hemispherical deflector analyzer (HDA) over a wide range of analyzer parameters. Results are presented for a typically dimensioned HDA with mean radius R-=101.6 mm and interradial separation ΔR=R2-R1=58.4 mm able to accommodate a 40 mm diameter position sensitive detector (PSD). Results for three different entry positions R0 are compared: R0=R- (the conventional central entry) and two displaced (paracentric) entries: R0=82.55 mm and R0=116 mm. Exit spreads Δrπ, Δtπ and base energy resolution ΔEB are computed for HDA pass energies E0=10, 100, 500, and 1000 eV, entry aperture sizes Δr0≤1.5 mm, entry angular spreads |αmax|≤5°, and an electron beam with relative energy spread δE/E0≤0.4%. Overall, under realistic conditions, both paracentric entries demonstrate near ideal field behavior and clear superiority over the conventional entry at R0=R-. The R0=82.55 mm entry has better absolute energy and time spread resolutions, while the R0=116 mm has better relative energy resolutions, both offering attractive alternatives for time-of-flight and coincidence applications where both energy and timing resolutions are important.http://dx.doi.org/10.1155/2015/153513
collection DOAJ
language English
format Article
sources DOAJ
author Omer Sise
Theo J. M. Zouros
spellingShingle Omer Sise
Theo J. M. Zouros
Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
Journal of Spectroscopy
author_facet Omer Sise
Theo J. M. Zouros
author_sort Omer Sise
title Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
title_short Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
title_full Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
title_fullStr Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
title_full_unstemmed Position, Energy, and Transit Time Distributions in a Hemispherical Deflector Analyzer with Position Sensitive Detector
title_sort position, energy, and transit time distributions in a hemispherical deflector analyzer with position sensitive detector
publisher Hindawi Limited
series Journal of Spectroscopy
issn 2314-4920
2314-4939
publishDate 2015-01-01
description Practical analytic equations, for the ideal field, and numerical results from SIMION simulations, for the fringing field, are presented for the exit radius rπ and transit time tπ of electrons in a hemispherical deflector analyzer (HDA) over a wide range of analyzer parameters. Results are presented for a typically dimensioned HDA with mean radius R-=101.6 mm and interradial separation ΔR=R2-R1=58.4 mm able to accommodate a 40 mm diameter position sensitive detector (PSD). Results for three different entry positions R0 are compared: R0=R- (the conventional central entry) and two displaced (paracentric) entries: R0=82.55 mm and R0=116 mm. Exit spreads Δrπ, Δtπ and base energy resolution ΔEB are computed for HDA pass energies E0=10, 100, 500, and 1000 eV, entry aperture sizes Δr0≤1.5 mm, entry angular spreads |αmax|≤5°, and an electron beam with relative energy spread δE/E0≤0.4%. Overall, under realistic conditions, both paracentric entries demonstrate near ideal field behavior and clear superiority over the conventional entry at R0=R-. The R0=82.55 mm entry has better absolute energy and time spread resolutions, while the R0=116 mm has better relative energy resolutions, both offering attractive alternatives for time-of-flight and coincidence applications where both energy and timing resolutions are important.
url http://dx.doi.org/10.1155/2015/153513
work_keys_str_mv AT omersise positionenergyandtransittimedistributionsinahemisphericaldeflectoranalyzerwithpositionsensitivedetector
AT theojmzouros positionenergyandtransittimedistributionsinahemisphericaldeflectoranalyzerwithpositionsensitivedetector
_version_ 1725600518571556864