Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
The paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Si...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2021-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf |
id |
doaj-96dec9fc028746b7abfb0172b407132d |
---|---|
record_format |
Article |
spelling |
doaj-96dec9fc028746b7abfb0172b407132d2021-08-05T12:53:51ZengEDP SciencesMATEC Web of Conferences2261-236X2021-01-013431002110.1051/matecconf/202134310021matecconf_mse21_10021Indoor air quality monitoring and human perception survey on air quality in public buildings in TimisoaraBere Semeredi Iudit0Valceanu Mihai Eugen1Nica Diana Mihaela2Sipetan Ella Anca3Corlan Romulus4Politehnica University of Timisoara, Faculty of Management in Production and TransportationThe City Hall of Timisoara, Environmental DirectorateThe City Hall of Timisoara, Environmental DirectorateThe City Hall of Timisoara, Environmental DirectoratePolitehnica University of Timisoara, Faculty of Electrical and Power EngineeringThe paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Six public buildings – schools and administrative edifices belonging to the municipality were subject of monitoring. An Andersen microbial air sampler was used to enumerate the numbers and different kinds of respirable bacteria and fungi inside of the selected classrooms and offices. The results of the specialized laboratory analyses indicate that the microbiological contaminant counts, expressed in colonyforming unit (CFU/m3), fall within the permissible limits for all monitored rooms. No beta-hemolytic streptococci or Staphylococcus aureus were identified, conditionally pathogenic bacteria for the upper respiratory tract. Most moulds were of the genus Penicillium, without having a pathogenic significance for humans. Occupants’ perception on indoor air quality, thermal comfort, health complaints and symptoms such allergies or respiratory illnesses with possible connection to the Sick building syndrome were surveyed by questionnaire. The findings were analysed and a plan to improve IAQ in the public buildings was proposed, with specific measures to increase the comfort and health of the learning and working environment.https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bere Semeredi Iudit Valceanu Mihai Eugen Nica Diana Mihaela Sipetan Ella Anca Corlan Romulus |
spellingShingle |
Bere Semeredi Iudit Valceanu Mihai Eugen Nica Diana Mihaela Sipetan Ella Anca Corlan Romulus Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara MATEC Web of Conferences |
author_facet |
Bere Semeredi Iudit Valceanu Mihai Eugen Nica Diana Mihaela Sipetan Ella Anca Corlan Romulus |
author_sort |
Bere Semeredi Iudit |
title |
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara |
title_short |
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara |
title_full |
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara |
title_fullStr |
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara |
title_full_unstemmed |
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara |
title_sort |
indoor air quality monitoring and human perception survey on air quality in public buildings in timisoara |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2021-01-01 |
description |
The paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Six public buildings – schools and administrative edifices belonging to the municipality were subject of monitoring. An Andersen microbial air sampler was used to enumerate the numbers and different kinds of respirable bacteria and fungi inside of the selected classrooms and offices. The results of the specialized laboratory analyses indicate that the microbiological contaminant counts, expressed in colonyforming unit (CFU/m3), fall within the permissible limits for all monitored rooms. No beta-hemolytic streptococci or Staphylococcus aureus were identified, conditionally pathogenic bacteria for the upper respiratory tract. Most moulds were of the genus Penicillium, without having a pathogenic significance for humans. Occupants’ perception on indoor air quality, thermal comfort, health complaints and symptoms such allergies or respiratory illnesses with possible connection to the Sick building syndrome were surveyed by questionnaire. The findings were analysed and a plan to improve IAQ in the public buildings was proposed, with specific measures to increase the comfort and health of the learning and working environment. |
url |
https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf |
work_keys_str_mv |
AT beresemerediiudit indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara AT valceanumihaieugen indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara AT nicadianamihaela indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara AT sipetanellaanca indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara AT corlanromulus indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara |
_version_ |
1721220850262212608 |