Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara

The paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Si...

Full description

Bibliographic Details
Main Authors: Bere Semeredi Iudit, Valceanu Mihai Eugen, Nica Diana Mihaela, Sipetan Ella Anca, Corlan Romulus
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf
id doaj-96dec9fc028746b7abfb0172b407132d
record_format Article
spelling doaj-96dec9fc028746b7abfb0172b407132d2021-08-05T12:53:51ZengEDP SciencesMATEC Web of Conferences2261-236X2021-01-013431002110.1051/matecconf/202134310021matecconf_mse21_10021Indoor air quality monitoring and human perception survey on air quality in public buildings in TimisoaraBere Semeredi Iudit0Valceanu Mihai Eugen1Nica Diana Mihaela2Sipetan Ella Anca3Corlan Romulus4Politehnica University of Timisoara, Faculty of Management in Production and TransportationThe City Hall of Timisoara, Environmental DirectorateThe City Hall of Timisoara, Environmental DirectorateThe City Hall of Timisoara, Environmental DirectoratePolitehnica University of Timisoara, Faculty of Electrical and Power EngineeringThe paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Six public buildings – schools and administrative edifices belonging to the municipality were subject of monitoring. An Andersen microbial air sampler was used to enumerate the numbers and different kinds of respirable bacteria and fungi inside of the selected classrooms and offices. The results of the specialized laboratory analyses indicate that the microbiological contaminant counts, expressed in colonyforming unit (CFU/m3), fall within the permissible limits for all monitored rooms. No beta-hemolytic streptococci or Staphylococcus aureus were identified, conditionally pathogenic bacteria for the upper respiratory tract. Most moulds were of the genus Penicillium, without having a pathogenic significance for humans. Occupants’ perception on indoor air quality, thermal comfort, health complaints and symptoms such allergies or respiratory illnesses with possible connection to the Sick building syndrome were surveyed by questionnaire. The findings were analysed and a plan to improve IAQ in the public buildings was proposed, with specific measures to increase the comfort and health of the learning and working environment.https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Bere Semeredi Iudit
Valceanu Mihai Eugen
Nica Diana Mihaela
Sipetan Ella Anca
Corlan Romulus
spellingShingle Bere Semeredi Iudit
Valceanu Mihai Eugen
Nica Diana Mihaela
Sipetan Ella Anca
Corlan Romulus
Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
MATEC Web of Conferences
author_facet Bere Semeredi Iudit
Valceanu Mihai Eugen
Nica Diana Mihaela
Sipetan Ella Anca
Corlan Romulus
author_sort Bere Semeredi Iudit
title Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
title_short Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
title_full Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
title_fullStr Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
title_full_unstemmed Indoor air quality monitoring and human perception survey on air quality in public buildings in Timisoara
title_sort indoor air quality monitoring and human perception survey on air quality in public buildings in timisoara
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2021-01-01
description The paper presents a study aimed at investigating the indoor air quality (IAQ) and people’s perception regarding the indoor environment of schools and public buildings in Timisoara. The indoor air quality monitoring was performed during the cold season, in the period January 2020 – February 2021. Six public buildings – schools and administrative edifices belonging to the municipality were subject of monitoring. An Andersen microbial air sampler was used to enumerate the numbers and different kinds of respirable bacteria and fungi inside of the selected classrooms and offices. The results of the specialized laboratory analyses indicate that the microbiological contaminant counts, expressed in colonyforming unit (CFU/m3), fall within the permissible limits for all monitored rooms. No beta-hemolytic streptococci or Staphylococcus aureus were identified, conditionally pathogenic bacteria for the upper respiratory tract. Most moulds were of the genus Penicillium, without having a pathogenic significance for humans. Occupants’ perception on indoor air quality, thermal comfort, health complaints and symptoms such allergies or respiratory illnesses with possible connection to the Sick building syndrome were surveyed by questionnaire. The findings were analysed and a plan to improve IAQ in the public buildings was proposed, with specific measures to increase the comfort and health of the learning and working environment.
url https://www.matec-conferences.org/articles/matecconf/pdf/2021/12/matecconf_mse21_10021.pdf
work_keys_str_mv AT beresemerediiudit indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara
AT valceanumihaieugen indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara
AT nicadianamihaela indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara
AT sipetanellaanca indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara
AT corlanromulus indoorairqualitymonitoringandhumanperceptionsurveyonairqualityinpublicbuildingsintimisoara
_version_ 1721220850262212608